Gas wall boiler thermon repair. Maintenance of gas boilers Thermona (Thermona). Wall mounted boiler repair work

Professional service of heating technology Thermona- the guarantee of its stable and effective work during years... The boilers of the Czech manufacturer are characterized by high performance and quality materials. With proper care and maintenance, these units will delight their owners not only with economical operation, but also with low fuel consumption.

Our center offers professional service for the entire line of THERM boilers. E-Tech masters have it all required tolerances and certificates for working with Thermona heating equipment. You can invite our specialists for a one-time service, or you can conclude a long-term agreement that provides significant discounts. We provide an official guarantee for all types of work and materials.

Service features of Thermona gas heat generators

Most models of THERM boilers are equipped with a copper heat exchanger protected from corrosion by a layer of aluminum-silicone. To maintain a minimum level of heat loss, outer surface the plates and the inside of the heat exchanger must be kept clean. As a preventive measure, it is recommended to install a filter at the return water boiler inlet.

Another feature of the Czech manufacturer's gas heat generators is the aluminum-coated combustion chamber sheet metal... This material is resistant to corrosion and various deposits. However, without regular cleaning, hidden defects can go unnoticed and grow into a serious problem. In addition, dirty work surfaces greatly reduce the boiler's performance, increasing fuel consumption and reducing heat transfer rates.

In the lower part of the combustion chamber of THERM boilers there is a water cooled gas-burner equipped with ignition electrodes and a control ionizing combustion electrode. Particular attention should be paid to this during routine maintenance. essential element heating system... Over time, due to the natural accumulation of soot and soot, its efficiency decreases. In this case, the reliability of ignition and the stability of combustion are significantly deteriorated. This leads to an increase in fuel consumption and the production of large volumes of carbon monoxide, which is dangerous to human life and health. Cleaning and timely replacement of spare parts during service maintenance helps to avoid all these problems.

Condensing gas boilers THERM 28 KD / KDZ / KDC, 45 KD are equipped with a siphon for collecting condensate. Care must be taken to keep the exhaust piping clean, otherwise, if the condensate outlet becomes clogged, resonance from the combustion chamber will follow.

Electric heat generators THERM EL, with a power of 5 to 45 kW, use powerful rods (up to six pieces) to heat water, operating according to the principle of uniform loading. The processor analyzes the operating time of the individual heating rods and always switches them on so that the load is evenly distributed both on the boiler body and on the heating rods. This significantly increases the service life of the device and its reliability. To keep the heating elements effective for many years, not much is required - regular cleaning, replacement of worn parts and correct operation of the control system. All these activities are included in the routine maintenance of THERM EL boilers.

The main protection function lies in the emergency thermostat built into the electric boilers. It blocks operation in the event of a malfunction. It is not possible to eliminate the malfunctions identified by the emergency thermostat by the user himself; unlocking can only be done manually by a service technician, after eliminating the cause
failure.

Floor-standing cast-iron boilers THERM are modern gas appliances used to heat apartments, mansions, medical institutions, shops and other facilities. The "heart" of these units is a gas burner with burner tubes made of of stainless steel, manufactured and located so that the amount of exhaust flue gases remains within the minimum range, and all boiler equipment works with high efficiency... A prerequisite for the correct operation of the burner is the precise positioning of the nozzles against the diffuser of the pipes. Therefore, in no case should the gas platform be deformed by unskilled actions. Only a professional service technician can adjust and balance the burner!

The most common and optimal boilers for creating cascade installations are the THERM DUO 50, DUO 50 T, DUO 50 FT, TRIO 90 and TRIO 90 T boilers in all their modifications. Other boilers with a capacity of 28 or 20 kW are also suitable for the cascade.

The technical solutions used in the boiler cascade system make it possible to combine all variants of THERM boilers with Dims control automatics. These include units with a digital display on the left side of the control panel. An exception are boilers with instantaneous heating of the hot water circuit CX and TCX. Efficiency cascade installation largely depends on the correct boiler room design. Particular attention should be paid to the calculation of the power. It often happens that as a result of overestimation or, conversely, underestimation of this parameter, the boiler room begins to not meet your requirements.

Ineconomic operation, unnecessary capital investment, or lack of heat are the most common consequences of design errors. Since our service center is part of the E-Tech Group of Companies, which provides a full range of services in the field of creating heating systems, our specialists can not only repair the THERM boiler, but also design, install and maintain a system of any complexity based on these boilers.


Gas heating boilers Vaillant
Models: floor-standing Atmovit exclusiv, wall-mounted condensing Ecotec plus. Service, maintenance, settings of functional components. Hydraulic diagrams.
Gas wall boilers Ariston
Clas, Clas Evo, Genus models. Recommendations for repair, maintenance and service. Elimination of errors and malfunctions. Setting and adjustment methods.
Gas boilers Immergaz
Models Eolo Star, Eolo Mini, Nike Star, Nike Mini, Metos. Repairs and adjustments. Installation, assembly and connection. Operating mode settings and additional equipment.
Kentatsu Furst boilers
Wall models Nobby Smart. Condensing Smart Condens. Floor standing Sigma, Kobold. Solid fuel Elegant, Vulkan. Malfunctions and error codes. Description and characteristics.

Thermona Boilers - Troubleshooting

I have a Thermona therm 14 TCL double-circuit boiler. Lately he began to supply too cold water to the hot water supply (heating is bad). Using the knob on the front panel, I regulate the water supply to the hot water supply to the maximum, but one or two LEDs light up, very rarely three. I tried to reduce the water pressure, but it did not help. This problem happens periodically (not always). If you switch the hot water tap several times to the on / off positions, the appliance starts to work as expected. I want to note right away that the degree of contamination of the heat exchanger is not high, since last summer I took it off and checked it. It was perfectly clean, and that's in 7 years of work. What to look for in the first place to solve this problem?

According to the passport data, this boiler is capable of heating water by 25C at a flow rate of 7-7.5 liters. If tap water coming to you, about 5-10 degrees, then the maximum possible heating will be no more than 30C (only one electrode will burn on the panel). By adjusting the flow rate, you can increase the temperature of the supplied water up to 40C, and sometimes up to 50C. But it is important to take into account that if the flow rate is reduced to 3 liters per minute or less, the flow sensor in the DHW circuit may not work and the burner will be automatically turned off.

After installation and installation of the gas wall boiler Thermon, DHW has stopped working. We have implemented it quite simply: water is supplied to the tap through a single heat exchanger. The heating circuit runs, switches on and heats up three times. If you open the hot water tap, the display shows an error F1. That is, in his opinion, there is a duct, but there is no ignition. Despite the fact that everything is normal during heating. I also note that if the tap is opened, then when it works for heating, it turns off. This means that the duct is still there, otherwise the unit would not react like that. For me, this situation is not clear: there is ignition, flow too, but the device does not work correctly. Tried unplugging
did a reboot, even turned the plug over. Did not help. Although the device is supplied good food, since it is connected through a stabilizer.

In my opinion, this malfunction can be in two cases: In the heat exchanger operating on the DHW circuit, some deposits have appeared that interfere with the normal flow in the system. The temperature sensor installed on the DHW circuit does not work correctly, namely, it greatly overestimates its value. Although, it is possible that there are two problems at the same time.

A therm duo 50 gas boiler was installed and put into operation. The following problem has arisen. When starting up, a spark arises during ignition, which is fed to the burner and quickly extinguishes. The display shows an error E01. What to do?

Error E01 most likely means that the ignition electrode is dirty. You should carefully clean it with a cloth. The gas pressure may also be weak, and because of this, the flame is very low (the device does not see that it is). The flame sensor insulator may be broken or the control board has failed. You also need to make sure that it does not break through anywhere.

We have a Thermon 14 single-circuit gas boiler operating in summer mode. To turn on the boiler, he repeatedly tries to start with a high temperature in the boiler. How to deal with this?

The three-way valve may have turned sour. To fix the problem, you must force it to open and close it several times. Possible breakdown of the boiler temperature sensor. If it works correctly, the three-way valve will not open until the temperature in the appliance exceeds the temperature in the boiler. The control board may also fail, since all the algorithms for the operation of the 3-way valve are written in it.

For some reason, the gas boiler Thermona therm 35, installed on the floor, goes out constantly and for no reason. The error can only be eliminated by pointing the fan at it. What is the reason for this?

Most likely, you have in a room where there is not enough air for the flame to burn. Or the ionization sensor itself is clogged. I have listed two of the most common reasons, but there may be something else.

In operation Thermon 45. Yesterday there was such a problem: the device got up by mistake "sensor failure heating water". Do I now need to drain all the water from the system for repairs, and how to fix the sensor itself?

Most likely, he got up by mistake E04 (breakdown temperature sensor heating). To replace it, the presence of water in the heating system does not interfere. You just need to cover shut-off valves... But such malfunctions are also possible: a short circuit in the circuit, a dirty mud filter, a breakdown or incorrect operation of the pump. Because of this, the device overheated from the hot water circulating in the system.

In case of breakdown gas boiler Thermona 28 error E06 appears on the display. The instructions say that the problem is in the thermostat. Where is it located to replace the sensor?

Error E06, means that an emergency shutdown has occurred due to overheating (emergency thermostat). Poor circulation in the heating system is also possible. If something happened to the hydraulics of the unit itself, it will also show exactly this error. Check the filter, the correct operation of the pump and sensor.

Thermona TCL-28, when working, it often began to show an E2 error. In addition, his pump burned out. Now you need to flush the heating system, adjust and adjust the entire device. Why did this happen, and what is the best way to follow the above procedures?

E2 error indication is more often given by low water pressure in the OS. There may be several reasons for this: a broken expansion tank or some kind of water leaks in the system.

A 20 kW gas boiler was installed. When the hot water supply is turned on, it displays the error E01. Then the scoreboard goes out and there are no signs of life. What could have broken?

It is possible that the ionization sensor touches the housing, and thereby closes the system. As an option also: a weak current on the gas valve control coil. The thrust rollover sensor may also be broken. And, as the most likely option, the control board of the device itself does not work.

Installed a Thermon gas wall boiler. At start-up, the appearance of the start of work is created, but the water supply pump for heating does not start. After a while, he stops. What could happen to him?

If we take the principle of operation of wall-mounted boilers, then they must have established that when the circulation pump is not working, they do not even start. You need to start the pump somehow, then the unit will not get up in case of an accident. On the back surface pump, you need to open the plug with a screwdriver and slightly turn the armature. In this case, the device must be in a disconnected state. Perhaps the anchor just stuck to the surface and needs a little help.

We have a Termona Duo 50 boiler installed. Periodically, an E01 error occurs, which entails the shutdown of the device. You can start it only forcibly, or by enabling the restoration of the ignition system. After that, he works in standard mode (from 30 minutes a day, approximately). I checked the nozzles and ignition electrodes. They are not contaminated. I called the technicians from the service department, and they expressed their version - the processor is faulty. Representatives gas service its own version. They are sure that the reason lies in airlock(my site is located at the very end of the gas pipeline, then there is a dead end). My neighbors do not have such problems. Tell me what is really going on with my device?

Your mistake is the most common with gas boilers. And there are a lot of reasons for its appearance. These can be "dips" in the mains voltage, problems with gas, breakdowns of the ignition and flame control electrodes, problems with the control board, oxidized contacts and much more.

Installed a Therm 50 boiler. Until recently, there were no complaints about its operation. However, recently it had to be turned off for 4 days. And now I cannot start it up. For 20-30 seconds, a spark is triggered, and then the emergency light flashes and it does not light up. The error is cleared, but the matter does not go beyond the spark. The machine is connected to the machine. Everything is outwardly in order, there is gas. What could it be?

According to the rules of the PUE, a plug must be mounted so that a visible disconnection of the contacts can be made. You have a unit installed that depends on the phase. Try to swap the phase and zero in places.

Already for a long time There are three therm boilers in operation and successfully operating - two 28 TLX in a cascade and one 32 TCLN. The first pair of them in 5 years of work did not create a single problem. Maintenance (disassembly and cleaning, as well as adjustment) is carried out by me approximately once a year. More often not necessary. But I can't handle 32 TCLNs. I can't even turn off the equithermal mode. It turned out to be turned on after disconnecting the sensor. I just don't pay attention to the error that occurs. How can I enter the service menu of this device?

To enter the service menu, you must set all the knobs to 7 o'clock, and then turn off the power to the unit itself. When turned on again, it will automatically start the self-test mode, and then will display "CC" for a couple of seconds. If this happened, then everything worked out and the weather-dependent mode is disabled. After that, by turning the knobs, you can adjust it as required. Next, unplug it from the outlet.
Disconnect the sensor from the automation board by disconnecting the valve. Extend the knobs on the control panel and turn on the power supply. Within 30 seconds, the automatics will make a self-test.

The pressure gauge on the front of Thermon 14 began to show very large numbers. However, his work has not changed - everything is as usual. What can this be connected with and is it necessary to make repairs?

This pressure gauge has nothing to do with the operation of the device. It only records the water pressure in it. The reading of this thermometer can be compared to any other pressure gauge in the system (if any).

When starting the gas boiler Thermona 45, the following happens: the pieza starts working, but when I switch to start mode, it goes out. What could it be?

Most likely, the flame generator has failed. This is the most common cause. But it is also worth checking the draft in the chimney, as well as the ignition nozzles for cleanliness.

I would like to install a control on the Therm 28 LX boiler three-way valve to the DHW using its board. Tell me if this connection and operation will be the same as in the description for LXZ. Or will the coolant stop when switching?

The algorithm is the same.

I use a 28 LXZ turbocharged gas boiler. Recently, two errors have appeared: E01 - constantly, E08 - much less often. When I reset the errors, its work is restored for a while. The device itself was serviced quite often. Can i eliminate this problem yourself, or will you need specialists?

It is required to clean the fan and chimney. If this does not help, then you will need to replace the monostat.

My device worked great, the service was always on time. And recently the error E01 began to appear. And yesterday E07 was added to it. What happened to him?

Judging by the errors, then there are problems with its ignition, with a chimney, or a breakdown of the monostat. Perhaps your supply ventilation is incorrectly installed or the chimney is freezing up.

For some reason, my boiler suddenly stopped due to error E06. How to fix it?

Error E06 corresponds to emergency overheating of the coolant. First of all, you need to check the mud filter, since if it is heavily clogged with dirt, the circulation of water in the system is disturbed. Look for the filter on the return pipe between the two valves. Disassemble and clean.

This error indicates that when the water is heated, it overheats. One of possible reasons there may be a breakdown of the temperature sensor responsible for heating the water. And also the heat exchanger can be "clogged" with scale.

Please tell me how you can regulate the temperature of hot water in model 28 LXZ 10. The knob located on the control panel does not work, and the wizard, when making the settings, did something inside under the lid. I needed to change the settings, and I do not remember how to do it.

Remove the front cover of the instrument. On the bar under it, you need to find a hole in which the slot of the DHW thermostat is visible.

Thermona 23 tcl worked for five bodies without breakdowns and any comments. A couple of weeks ago, the pressure on the gauge rose to 2.5, and the explosive valve began to leak. How can I find out: I have a problem with the heat exchanger or with the make-up tap. Finding out the causes of the problem, I found out that a heat exchanger made by the Italian company MUT is installed in my unit. And as I read, there are very bad reviews about her. With a heat exchanger, what good and proven company can I replace?

It is necessary to set the air pressure specified by the manufacturer in expansion tank... About 80-90% of boilers are manufactured without an integrated make-up line.

I have a 14 TCL boiler installed. When it is turned on, for some reason the fan does not start up, but it stops itself due to an accident. Inspection of the device did not reveal any visible wire breaks. The vacuum relay has recently been changed. What else could be the cause of this problem?

Your model has a two-position vacuum relay. And it is it that commands the closure and opening of contacts (the features of the work depend on the model itself). Since you have ruled out the problem with the relay, the breakdown is most likely in the control board.

Thermon 28 boiler is connected. Recently, a problem has arisen at startup. If it was turned off for a long time, then at startup it works for exactly 10 seconds and then turns off.

You have a natural draft machine installed. It is very important for their correct operation that the chimney is in good condition. Perhaps your thrust rollover sensor is triggered, and that is why it stops in an accident. Further, after it cools down, it becomes possible to start again. Check the chimney for leakage and provide a better air supply to the boiler room.

Thermon 14 boiler is faulty. When looking for a possible breakdown, I checked everything I could, but did not find the cause of the damage. He was the only one who noted that the flame of the burner was somehow yellow. Maybe the problem is the quality of the gas?

Check the inlet gas supply pressure (probably insufficient) or you have a problem with the air supply. Once again, you need to check the device for breakdowns.

The thermon double-circuit boiler (28 kW) has broken down. Does not heat water. What could have broken in him? And how much might the repair cost?

Unexpected interruption of DHW operation indicates that the flow meter is broken or the heat exchanger is heavily contaminated. Check the operation of the flow sensor and, if necessary, install a new sensor.

The boiler pressure gauge indicates that the pressure in the tank is too high. But on batteries, in the heating system, with pressure, everything is normal. Is it possible that the pressure gauge itself is dirty? Can it be changed in the event of a breakdown?

If the pressure in the apparatus really exceeded the permissible limits, it would have worked emergency stop... The pressure gauge can be checked as follows: release all pressure from the device and look at the readings. Its arrow should point to 0. We also advise you to check the mud filter, since it is its purity that directly affects the readings of the pressure gauge on the unit. If you need to change the pressure gauge itself, be prepared for the fact that the water will have to be drained from it.

Thermon cauldron 50, has stopped dispensing hot water... And cold water comes in, but there is nothing at all at the exit. What to do?

If water enters the hot water supply, but does not come out, the heat exchanger should definitely be checked. It is also possible that the water supply is mechanically shut off somewhere. Perhaps the gasket has squeezed out, and it clogged the passages in the heat exchanger. Try to feed the water in the opposite direction.

The wall mounted Thermon 14 boiler was installed in operation. When you try to start it, it stops after three seconds. Previously, mechanical shock to the device helped. Now that doesn't work either. What is the reason for the breakdown?

If you believe your description, then there is a loose contact on the board or in some other place. Check the electrical, clean and fix all the contacts on the board.

Model 28 tlxz keeps the burner at maximum power at all times and does not try to operate it. Maybe you should check the gas valve modulation coil? How to do it? How should the circuit be closed: maximum or minimum?

The coil cannot change its state, it is not a relay. Its main property is the presence of resistance. If the valve is operating at maximum, then everything is normal with it. There is a possibility of the valve sticking open, but it is very small. Check the fee.

The device constantly stops due to an alarm when the DHW circuit is running. What could be the problem?

Check flow sensor or secondary heat exchanger for flow.

___________________________________________________________________________________________

    It must be said that regardless of the specific breakdown all repair work must be carried out exclusively by professional specialists... This will allow not only to fully restore the performance of the equipment, but also guarantee the trouble-free subsequent operation.

    Also, our specialists offer the service of urgent repair of Thermona heating boilers (Thermona). Often, such an urgent need for repair arises when equipment breaks down during the heating season. The efficiency of the repair work performed in this case directly affects the comfort of living in the house. Note that we have all the necessary high-quality original spare parts in our warehouse, which allows our specialists to maximize short term eliminate existing equipment breakdowns.

    You can call a specialist to solve your problem. Fill out the form, briefly describe your problem and we will call you back for consultation.

    We repair all gas boilers, including

    Prices

  • Service Price
  • Departure of the engineer to work time from 8:00 to 22:00
  • Within small concrete ring 2000 RUB
  • Tariff when driving to the object outside the small concrete ring, per km. round trip RUB 30
  • Departure to holidays × 1.5
  • Departure outside working hours from 22:00 to 8:00 in the morning× 2
  • Diagnostics
  • Fault diagnosis (up to 2 working hours) 2000 RUB
  • Fault diagnosis (more than 2 working hours) RUB 1,500 at one o'clock
  • Replacement / installation of gas and fuel fittings and devices
  • Cleaning, replacing the electrode with setting gaps 1000-2000 rub.
  • Cleaning, replacing the photocell 1000-2000 rub.
  • Replacing the control box, combustion manager 1000-2000 rub.
  • Fan replacement RUB 1500-3000
  • Replacing the burner actuator (without adjustment) 3000-5000 rub.
  • Replacing the transformer 3000-4000 rub.
  • Replacing the nozzle from 3000 rubles.
  • Replacing the fuel filter from 5000 rub.
  • Replacing the diesel burner fuel pump from 5000 rub.
  • Installing the fuel level sensor
  • Bleeding the fuel line
  • Replacement / installation of water fittings and devices
  • Circulation pump from 3000 rub.
  • Pumping group from 3000 rubles.
  • Make-up heating systems with a pump from 1500 rubles.
  • Security groups from 3000 rub.
  • Automatic air vent from 2000 rub.
  • Mixer servo RUB 3000
  • Distributor comb from 5000 rub.
  • Installing the filter rough cleaning from 4000 rub.
  • Cleaning the coarse filter from 600 rubles
  • Repackaging engineering system for 1 point from 3500 rub.
  • Replacing the wall-mounted boiler pump from 3000 rub.
  • Replacing the primary heat exchanger of a wall-hung boiler from 4000 rub.
  • Replacement secondary heat exchanger wall boiler from 4000 rub.
  • General
  • Repair, replacement, installation and commissioning of automation
  • Replacement electronic board RUB 3000
  • Replacing the control panel from 3000 rub.
  • Replacing the thermostat 3000-5000 rub.
  • Replacing the thermocouple from 3000-5000 rub.
  • Replacing the thermostat 2000 RUB
  • Installation, commissioning of weather-independent automation from 7500 rub.
  • Installation, commissioning of weather-dependent automation up to 3 heating circuits from 7500 rub.
  • Installation, commissioning of weather-dependent automation up to 5 heating circuits from 8500 rub.
  • Assembling the controller from 6000 rub.
  • Setting up weather-independent automation from 5000 rub.
  • Setting weather-dependent automation from 5000 rub.
  • Connecting an additional boiler automation module from 3500 rub.
  • Installing the sensor outside temperature, room regulator(not including cable installation) 2000 RUB
  • Installing the line temperature sensor RUB 1000
  • Installing the flue gas temperature sensor RUB 1000
  • Installing the overturning draft sensor from 1000 rub.
  • Installing the boiler body temperature sensor from 1000 rub.
  • Installing the boiler sensor from 2500 rub.
  • Installing and configuring the servo from 2500 rub.
  • Installation and connection of the relay contactor from 2500 rub.
  • Installation of an additional automation module from 3500 rub.
  • Replacing an additional automation module similar to the one installed from 2000 rub.
  • Replacing an additional automation module that is not the same as the one installed from 2500 rub.

Customer Reviews

22.11.2017

Many thanks to Denis and Ivan for their help in repairing the heating system at the SNT Sokol dacha. Everything was done quickly, competently and accurately. It is a pity that they did not immediately apply to the "Complex of Ideas". I will gladly use the help "A set of ideas" in the future, because it is clear that people know their business and can solve the problems that arise during the operation of suburban housing.

07.07.2017

In the summer, as a preventive measure, I wanted to flush the heating system. I phoned a dozen companies, spent a week - either the price is high, or they do not inspire confidence, or there are some other restrictions. Some said that they would be washing it for 3 days, removing all the batteries in the house - 50 thousand more were announced.
... The next day we arrived and in one day everything was done with the help of some kind of special compressor + chemistry. Quickly,…

11.02.2017

Thanks to the employees of the company "A set of ideas" for the work done. Really saved in New Year!!!

09.01.2017

At the beginning of January 2017, it was very cold in the Moscow region and our gas boiler went out and we could not start it. Before that, he periodically "clapped" and "clicked", but we did not attach any importance to this. And then ... New Year's, the whole family at the dacha, and the boiler broke down. It's good that the specialists The “set of ideas” came and solved our problem. Almost froze :)

I recommend it to everyone! The telephonists of the masters were written with a marker directly on the boiler.

22.09.2016

I would like to write a review about the work of an employee of the "Complex of Ideas" company. When the cold weather came, there was a problem with the heating boiler in country house- I wrote an error Error I do not remember which number. They found the first website on the Internet on the phone, called. We arrived, repaired, took quite a bit for the money. Very efficient, polite and only pleasant impressions were left. It seems the employee's name was Vadim or Vlad - I didn't remember exactly =)

07.05.2016

I spent the whole weekend trying to connect a boiler in the country to heat water ... I went to the market 3 times for additional details, rummaged through the entire Internet - I just can't do it. It does not turn on, then it flows, then something else. I found this site on the Internet, called - they arrived, they did it in 50 minutes, which took me 2 days! I should have called right away. I would have rested better. Next time I will!

16.03.2016

I express my gratitude to the specialist Victor from "A set of ideas"! I arrived, repaired our gas boiler, replaced something there - voila, it all worked. I couldn't have done it myself.

Other materials

Filters for water disinfection (biological treatment)

Concerning country cottage or summer cottages, then the question is even more acute, because water is supplied directly ...

Installation of XLPE pipes

The most remarkable thing about the XLPE piping system is its versatility. They are used in ...

Replacing batteries and radiators

Before deciding on the modernization and replacement of elements of the heating system, you need to know exactly which type of batteries is suitable ...

Final purification of water from a well and a well

Before using water from a well or well in economic purposes, at the enterprise, it must undergo final cleaning.

Sorption treatment of water from a well and a well

Sorption water treatment is The final stage water treatment, which removes chemical and metal impurities, ...

We have a team of certified engineers (each employee has an SRO admission and a license for the corresponding activity). Having received an application for the repair of the Thermona boiler, we send the masters to the address you specified.

Restoration of water heating equipment does not take much time. Having found out the nature of the malfunction by phone, our employees take with them to the exit not only everything necessary tools, but also spare parts: gas choke, relays, burners and others. Please note that for a high-quality repair of Thermona boilers, it may be necessary to replace not only small components, but also entire units.

Additional Information

Having studied in detail the design of the famous Thermona boilers and learning methods for eliminating typical malfunctions, we restore this equipment to its factory condition. The service center provides a 1 year warranty for the work performed, as well as for spare parts used during the repair of the Thermona boiler.

The mobile team serves all districts of the capital, as well as the region. Our service center accepts applications around the clock and seven days a week. You can rely on the help of experienced engineers. As for the cost of repairing Thermona boilers, it is calculated individually for each client.