Errors of boilers neva lux and their codes. Errors of gas columns Neva Lux Gas boiler Neva error 03

This article contains all possible malfunctions and options for their elimination, as well as error codes for Neva Lux boilers. All information is read in next order: code - name - possible malfunction... If you have any additional questions, please leave them in the comments to this article.

If you are not 100% sure what the problem is and that you can solve it, immediately contact the service center for diagnostics and troubleshooting.

Find out the price and buy heating equipment and related products you can contact us. Write, call and come to one of the shops in your city. Delivery throughout the territory of the Russian Federation and the CIS countries.

If the Neva Lux boiler has a failure or incorrect operation of any of its systems, it will display the corresponding error code on the display. This makes it easy to find and fix the breakage.

Error code 01 - Ignition error

This code means that the boiler has a problem with ignition. In this case, the device does not start up. Possible reasons:

  1. There is no gas supply. It is required to check the shut-off valve on the gas pipeline. If everything is in order there, then it is necessary to measure the pressure in the cylinder, provided that the unit operates on liquefied gas.
  2. The ignition plug is broken. Unrepairable, replacement required.
  3. Problems with the electrical circuit of the spark plug. To eliminate it, you need to check the contacts and the circuit itself.
  4. Incorrect gap set between the spark plug and the burner section. Adjust the gap according to the instructions. It should be 5 mm with a tolerance of no more than 0.5 mm.
  5. The spark coming from the electrode of the candle jumps to the shell of the combustion chamber. To eliminate it, you need to move the shell by bending it together with the installation of the candle.
  6. The spark plug is covered with dirt. It is required to clean and degrease.
  7. Breakage of the ionization plug. Replacement required.
  8. Problems with the electrical circuit of the ionization plug. A check of the circuit itself and contacts is required.
  9. Breakdown of the ignition transformer. Install a new one.
  10. The electrical circuit of the ignition transformer is damaged. Check the circuit itself and the contacts.
  11. Burner block dirty. Clean up.
  12. Gas regulator electrical circuit problem. Check circuit and contacts.
  13. Gas regulator defective. Replace it.
  14. Thermal relay breakage. During normal operation, it should open at a temperature of 90 degrees. Replacement required.
  15. The electrical circuit of the thermal relay is damaged. Check the electrical circuit of the heating sensor and its contacts.

Error code 02 - The water temperature has exceeded the permissible value

This code means that the water temperature has exceeded the permissible value. The BaltGaz boiler is out of service due to an accident. Possible causes and elimination algorithm:

  1. There is no flow in the heating system due to severe blockages. Cleaning required.
  2. Thermal relay breakage. Normally, it should open at a temperature of 90 degrees. Its replacement is required.
  3. There is air in the heating system. Drain it through the bleed valve.
  4. Heavy contamination of the filter located in the heating system. Cleaning is required.
  5. Valve and bypass problems. Most likely, it is not installed correctly or is broken. Check that its installation was according to the instructions, if necessary, replace it.
  6. Breakdown of the pump. Replace.
  7. Breakage of the air outlet valve. Replacement required.
  8. Breakdown of the pump relay located on the electronic board. Board replacement required.
  9. Breakdown of the gas supply regulator. Install a new one.
  10. Incorrect gas regulator setting. Carry out the setting according to the instructions.
  11. The electrical circuit of the overheating sensor is damaged. Check the contacts and the circuit itself.

Error Code 03 - Lack of Traction

This code reports the absence of traction. The device has been stopped due to an alarm. Possible causes and remedies:

  1. Exhaust gases are not discharged; therefore, the chimney may be clogged. Clean it up.
  2. Poor air supply to the firebox. Clean the air intake duct.
  3. There is no tightness of the pressure switch tubes. Replace.
  4. Problems in the electrical circuit of the pressure switch. Checking of contacts and circuit is required.
  5. Breakdown of the pressure switch. During normal operation, the pressure switch contacts are closed if the pressure drop is equal to or greater than 130 pascals. Replacement required.
  6. Condensation has accumulated in the pressure switch tubes. Remove condensation.
  7. The fan electrical circuit is damaged. Check circuit and contacts.
  8. Fan breakage. Repair or replace.

Error code 04 - Insufficient water pressure in the heating circuit

It shows that the water pressure in the heating circuit is insufficient. The Neva Lux boiler has been shut down due to an accident. Causes and ways to eliminate them:

  1. The water pressure in the heating system is below normal. Top up the heating circuit with water up to the manufacturer's required reading on pressure gauge.
  2. Airiness of the system. Drain the air outlet through the valve.
  3. Breakage of the water pressure sensor located in the heating circuit. Sensor replacement required.
  4. Breakdown of the pump or air vent valve. Repair or replace.
  5. The electrical circuit between the pressure sensor and the electronic board is damaged. Check the contacts of the connectors in the control unit, as well as the contacts on the sensor. Check the electrical circuit for continuity.

Error code 05 - Error of the temperature sensor responsible for heating

There is a problem with the temperature sensor responsible for heating. The unit has been stopped due to an accident. Causes and ways to eliminate them:

  1. Broken temperature sensor. Its replacement is required.
  2. Circuit problem between the temperature sensor to the electronic board. Check circuit and contacts.

Error code 06 - DHW temperature sensor error

Indicates that the DHW temperature sensor is faulty. The BaltGaz boiler operates only for heating. Possible causes and their elimination:

  1. Damage to the DHW temperature sensor. Replace it.
  2. The electrical circuit between the sensor and the board is damaged. Check her and her contacts.

Error code 07 - Error in the operation of the modulator coil of the gas supply regulator

Incorrect operation or breakdown of the gas supply regulator modulator coil. The device has been stopped due to an alarm. Possible causes and their elimination:

  1. Breakage of the gas regulator modulator coil. Normally, its resistance should be 80 Ohm. In the event of a breakdown, replacement is required.
  2. There is no contact between the modulator coil and the electronic board. Check the electrical circuit and the contacts themselves.

Existing breakdowns in which errors do not appear on the device

If the electronic display of the Neva heating boiler does not show an error code, but the equipment does not turn on, pops are heard, there is a smell of gas, etc., then this may also indicate an existing breakdown of the system. Inspect the boiler, fix the problem, find its description in this article below and fix the problem in time.

Unable to turn on the Neva Lux boiler

  1. There is no electricity in the network. Contact your electricity supplier.
  2. The fuse in the circuit board has blown. Its replacement is required.
  3. Moisture has gotten on the electronic board. To fix, try drying the board with slightly heated air, or remove the board and place it in a dry place for a few days. warm room... It is important that the water evaporates completely.
  4. Possible breakdown electronic board... In this case, the "reset" button will not help. To fix it, you need to disconnect the device from the network and try to turn it on again. If this does not fix the problem, then a new card should be installed.

There are pops in the burner

  1. The settings for the minimum gas pressure and ignition power have been set incorrectly. Re-adjustment of these parameters is required.
  2. Burner air supply too poor. To eliminate it, it is necessary to clean the pipe or channel through which the air is supplied.
  3. Problems with spark from spark plug electrode. It slips onto the edge of the burner section or onto the shell of the combustion chamber. To eliminate it, it is necessary to slightly bend the ignition plug, or, conversely, move the shell away from the combustion chamber. This will ensure that the spark hits the area of ​​the burner section nozzle holes.
  4. The burner block may be dirty. It needs cleaning.

During the operation of the Neva Lux boiler, a strong gas smell is felt

  1. Perhaps the tightness is broken somewhere and the gas is leaking. Check your circuit for leaks and locate gas ingress points in the room. Eliminate.
  2. There is no hot water in the taps or very weak pressure... Pressure cold water supplied to the DHW circuit is insufficient for correct operation. Contact your cold water supplier.
  3. The water filter is heavily soiled. It needs cleaning.
  4. The filter is on the DHW line. In the taps, the water temperature is much higher than the set one. To eliminate this problem, it is necessary to increase the amount of water passing through the DHW circuit. Can also be thinned hot water cold. However, the flow rate cannot be reduced.

Too low water flow through the DHW

Enlarge it.

The device works fine in DHW mode, but does not work for heating the house

  1. Room thermostat jumper missing. Install it.
  2. Broken room thermostat jumper, which closes the contacts. Replacement required.
  3. Possible breakdown of the room thermostat itself. Replace.

The system is supplied with a temperature lower than specified by the setting

Broken sensor for controlling the temperature of the water supplied to the heating. First of all, descale this sensor. This is true if an immersion sensor is installed. Or replace it.

When the device is in pause mode, it shows on the display the symbol "-"

At the same time, it does not respond to any buttons. The voltage supplied to the device has become more than 190 - 250 volts. To eliminate this problem, ensure that the voltage supply is within the permissible range. Every 30 seconds, the unit tries to start in automatic mode, and it will do so until the problem is solved.

Codes of errors and malfunctions of boilers Neva Lux

The shutdown of the Neva Lux boiler caused by a failure or improper operation of any of its systems is accompanied by the corresponding error code flashing on the control panel display, which makes it easier to detect the malfunction.

Error codes, possible reasons and troubleshooting methods

Error 01- Problems related to unsuccessful ignition. The boiler is not working.

Gas supply faults - Open the shut-off valve on the gas pipeline, or check the pressure in the cylinder (LPG.)

Ignition plug defective - Replace spark plug.

Spark plug electrical circuit interrupted - Check electrical circuit and contacts.

Incorrect gap between spark plug and burner section - Set gap (5 + 0.5 mm).

The spark from the spark plug electrode jumps onto the combustion chamber shell - Bend the combustion chamber shell at the place where the spark plug is installed.

The spark plug is dirty - Wipe the spark plug from dust and degrease.

Ionisation plug defective - Replace plug.

Ionization plug electrical circuit interrupted - Check electrical circuit and contacts.

Incorrect gap between ionization plug and burner section - Set gap (3 + 0.5 mm).

Ignition transformer defective - Replace the Neva Lux boiler ignition transformer.

The electrical circuit of the ignition transformer is interrupted - Check the electrical circuit and contacts.

Burner block clogged - Clean burner block.

Gas regulator electrical circuits interrupted - Check electrical circuits and contacts.

Error 02- Overheating of water. The boiler is not working.

Clogged heating system - Clean the heating system.

Thermal relay defective (normally closed at temperatures up to 90 ° C) - Replace the thermal relay.

Filter in heating system clogged - Clean filter.

Defective or incorrectly installed, bypass valve - Check that the bypass valve parts are correctly installed and replace if necessary.

Defective pump or vent valve - Replace pump or vent valve.

Defective pump relay on the electronic board - Replace the electronic board.

Gas regulator not working - Replace gas regulator.

Gas regulator not adjusted - Adjust gas regulator.

Thermal relay (overheating sensor) electrical circuit broken - Check electrical circuit and contacts.

Error 03- Lack of traction. The Neva Lux boiler does not work.

Chimney or air duct blocked - Find out the cause of the blockage and remove it.

The tightness of the pressure switch tubes is broken - Replace the tubes.

Violation of the electrical circuit of the pressure switch - Check the electrical circuit and contacts.

The pressure switch is faulty (the contacts of the press switch must close at a pressure drop of 130 Pa) - Replace the pressure switch.

Condensation in the pressure switch tubes - Remove condensation from the pressure switch tubes.

Violation of the electric circuit of the fan - Check the electric circuit and contacts.

Fan defective - Replace fan.

Error 04- Insufficient water pressure in the heating circuit. The boiler is not working.

Reduced water pressure in the heating circuit - Bring the water pressure in the heating circuit to the recommended value.

Air lock in the heating system - Open the air bleed valve.

The water pressure sensor in the heating circuit is faulty - Replace the sensor.

Defective pump or vent valve - Replace pump or vent valve.

The electrical circuit between the pressure sensor and the electronic board is broken - Check the contacts of the connectors in the control unit and on the sensor and the sensor's electrical circuit.

Error 05- Failure of the heating circuit temperature sensor. The boiler is not working.

Heating circuit temperature sensor defective - Replace the heating circuit temperature sensor.

Electrical circuit "temperature sensor - electronic board" broken - Check the electrical circuit and contacts.

Error 06- Failure of the DHW temperature sensor. The Neva Lux boiler works only in heating mode.

DHW temperature sensor defective - Replace DHW temperature sensor.

The electrical circuit between the DHW temperature sensor and the electronic board is broken - Check the electrical circuit and contacts.

Error 07- Malfunction of the gas regulator modulator coil. The boiler is not working.

Broken gas regulator modulator coil - Replace the gas regulator (modulator coil resistance 80 Ohm).

Electrical circuit "modulator coil - electronic board" broken - Check the electrical circuit and contacts.

Malfunctions of boilers Neva Lux without an error code

Neva Lux boiler does not turn on

Lack of electricity - Contact the electricity service.

Fuse blown - Replace the fuse on the board.

Water ingress on the electronic board - Dry the board with warm air or leave it for two days in a dry place to completely evaporate the water.

Failure of the electronic board (RESET does not help) - De-energize and restart the boiler or replace the electronic board.

Pops in the burner

The minimum gas pressure and ignition power have been set incorrectly - Adjust the minimum gas pressure and ignition power.

Insufficient air supply - Clean the air intake pipe or duct.

The spark from the electrode of the spark plug jumps to the edge of the burner section or to the shell of the combustion chamber - Bend the spark plug or bend the shell of the combustion chamber, ensuring spark slip into the area of ​​the holes in the nozzle of the burner section.

Dirty burner block - Clean burner block.

Gas smell

Gas leaks - Check the entire gas circuit for leaks, eliminate gas leaks.

Little or no hot water output

Insufficient water pressure at the inlet to the hot water supply - Contact the housing and communal services service.

Water filter clogged - Clean the filter on the DHW line.

Heat exchanger clogged - Clean the heat exchanger.

Not supported set temperature hot water (too high)

High inlet water temperature - Increase the flow of water through the DHW circuit or dilute the hot water with cold water, avoiding a decrease in the flow through the DHW circuit.

Small water flow through the DHW circuit - Increase the water flow through the DHW circuit.

Neva Lux boiler does not work in heating mode (but works in DHW mode)

Room thermostat jumper missing - Install the room thermostat jumper.

The room thermostat jumper connecting the contacts is faulty - Replace the room thermostat jumper.

Room thermostat defective (if a thermostat is installed) - Replace the room thermostat.

The temperature of the water entering the heating system is lower than the set

Heating circuit temperature sensor defective - Clean the temperature sensor from scale (if using an immersion temperature sensor), or replace the temperature sensor.

The boiler is in standby mode, the display shows the symbol "- -" and the boiler does not respond to pressing the control buttons

The supply voltage is outside the range of 190 ÷ 250 V - Restore the supply voltage within the range of 190 ÷ 250 V. After 30 seconds, the boiler will automatically start in the mode in which it was before the voltage went beyond 190 ÷ 250 V.

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

_______________________________________________________________________________

__________________________________________________________________________

OPERATION AND REPAIR OF BOILERS

The problem is that I bought this long ago washing machine Indesite wise107s and bought another daughter for my daughter. top panels the bottom on the sides is not peeled off nicely. Now, if the manufacturers thought that many people complain about the painting of the car. Invented a good painting, then nothing else needs to be invented. The model would be better. Can't compare with the indesite of Ukrainian manufacturers. You could trade one This model. People know that she is super, I don’t need another. I would have bought the same one, but unfortunately it was removed from production. It's very bad, I don’t want another model, I don’t want even a better one. I already know it. But I bought my daughter from the bay of a flounder and it's not that coat. People want to buy, want to spend their money, and manufacturers are in a hurry for different bells and whistles for cars. But we don't need all sorts of cool bells and whistles, in Kharkov the price of electricity is crazy. Soon people with such prices will stop buying altogether It’s enough that we once bought toasters, microwave bread makers, multi-cookers, toasters, coffee makers, now everything is lying around as unnecessary, because the price for electricity is exorbitant, and the wages are pretty penny. e goods are not for us. So if you want people to buy something, you have to do something for this with the prices of the goods, and most importantly with the price of electricity, otherwise all large supermarkets will soon have to be closed, and they will not be profitable. she worked for many years in the Barabashova market. Previously, people bought up heaps of goods, but now they have closed half of the shops. There is no imported goods, but they sell such dreck, they have nothing to buy. No good boots, no good clothes. There is nothing to look at, everyone runs away from the market. in another business. The bazaar is dead, there is nothing to do. So are electronics supermarkets. Do the owners of large stores really do not understand this, because the owners are rich people. then these rich people will try to sell their store or a bunch of goods that have turned into old junk, which no one takes. After all, you can buy everything now without leaving your home. Who needs to buy online and cheaper and do not have to go for three nine lands to burn benz in order to buy household appliances in the supermarket. People are not fools to pay more for renting a store for the salaries of sellers, managers and servants. They will not steal. A good product should cost money, but excuse me not so much as we even sell medicines through fourth hands. For example, a factory abroad produced a good medicine, selling it made money on this medicine. It was bought by wholesalers who brought it to our city, sold it to the warehouse, we also earned money. Then they brought it to the pharmacy, they sold it to us, too. , so pharmacies are now like uncut dogs, at every step. They also sell electrical household goods. Finding something real good now is also a problem. Cigarettes and those are counterfeit, if they grew tobacco, dried it, made cigarettes from it, then already would fly into the pipe and go bankrupt. That tobacco would not grow, then not the harvest, etc. So they need to make money on you. There is no tobacco, and all kinds of grass with additives and flavors. That's all. The owners of the Bentley factory have a three-story mansion. And you have a cough, shortness of breath and lung cancer, to help out the pharmacy business. Remember the film has long been YOU FOR ME, I FOR YOU. Do not help out deceivers with vodka, the same thing, Deshmanov alcohol plus distilled water. And that's all. Durilovka is in everything. People will be vigilant. , oh, how I am all of you x sorry.

2017-05-17 Evgeny Fomenko

The device and principle of operation of boilers Neva Lux

Gas boilers Neva Lux are presented in two variations - wall-mounted and floor-standing, consider their device using some models as an example. Neva Lux 8618 is a single-circuit heating boiler, wall-mounted installation method, has low level energy consumption, a fairly high efficiency of 91%, power 18 kW. It can heat a room with an area of ​​30 to 180 square meters.

Works from both natural and liquefied gas... It has small dimensions, it is equipped with a combustion chamber that is cooled with water, it can also be connected to room thermostat which is convenient to use. Equipped with a protection device against overheating (boiling), a thermostat against overheating of the gas exhaust device. It can be connected to both the chimney and the turbo nozzle.

Neva Lux 8224 is a double-circuit gas boiler designed to heat a room up to 240 meters2, as well as to heat water for household needs, throughput 14 liters per minute. Its power is 24 kW, it is equipped with closed chamber combustion.

The installation method is wall-mounted, equipped with a built-in 6-liter expansion tank, which makes it possible to connect the boiler to a 70-liter heating circuit. The design provides for two heat exchangers, copper for the heating circuit, and the second, from of stainless steel, for hot water supply.

Powered by natural or liquefied gas, for ease of use it has a display that reflects the current and set temperature in the coolant.

Neva Lux 7224 is a wall-mounted, double-circuit device designed for heating a room with an area of ​​up to 240 m2, the throughput of water for domestic needs is 14 liters per minute. Can work from natural gas and liquefied, coefficient useful action 92%.

Boiler Neva Lux 7224

Equipped with a bithermal heat exchanger, thanks to which it is possible to reduce the final cost of heat. Equipped with electronic system self-diagnostics, and also a small display is installed on the case to indicate readings.

Neva deluxe 7023 - wall mounting, designed for heating a room up to 250 meters2, as well as heating technical water 13 liters per minute. It works not only from natural gas, but also from liquefied gas; for ease of operation, you can connect a room controller.

The smoke is removed forcibly, with the help of a built-in fan, air for burning the fire is forced from the street. Equipped with a closed combustion chamber, has a coaxial heat exchanger, expansion tank volume of 6 liters.

Neva Lux 8023 is a double-circuit wall-mounted boiler, which has the ability to provide heat to a room, the area of ​​which does not exceed 240 m2. The circulation of the liquid in the system is forced, with the help of a pump, equipped with a closed combustion chamber.

Exhaust is due to exhaust fan... The power of the device is 23 kW, the presence of two heat exchangers is provided, the heating circuit is of paramount importance, made of high-alloy stainless steel.

Major error codes

Like any other device, it periodically fails, then we will consider in detail the error codes for the Neva Lux gas boiler.

Control Panel gas boiler Neva Lux

e1

Error e1. This malfunction indicates a low fluid pressure in the heating circuit.

The reasons may be as follows:


e2

Error e2. Failed ignition, check the following:


e6

Error e6. No cravings. Check the possible causes of this malfunction:


e7

Error e7. Exceeding the permissible temperature in the coolant.

What are the possible reasons and what to do, we will consider in more detail:


01

Error 01. Malfunctions caused by unsuccessful ignition.

Possible reasons:


02

Error 02. Indicates boiler overheating.

Possible reasons:


03

Error 03. In order to fix it, check:


04

Error 04. Low pressure in the heating circuit, you need to check:

  • Too much decreased pressure in heating system , raise it to the recommended level.
  • Perhaps in the system formed airlock , remove it using the vent valve.
  • Broken pressure sensor in the heating circuit. Replace it.
  • The pump is broken, clean it and replace if necessary. Visually inspect all connections and connectors on the control board.

In chapter Service, maintenance and repair to the question Boiler neva lux 8224. constant error 03. condensate accumulates in the pressure switch tubes. How to fix this problem. given by the author Vladimir the best answer is Need more detailed information about where it is located, outside temperature, fuel (gas or diesel fuel), winter or summer, etc. And condensate from what (water, gas)?
What can be done to prevent condensate from collecting in the pitot tubes? The Neva Lux 8224 boiler turns off every year in January, showing error 03. Of course, I eliminate the condensate and start the boiler until the next accumulation of condensate, but this problem is pretty boring. Help!

Answer from Yotas Shabanov[guru]
1. Check if the tap is completely closed.
make-up.
2. If the make-up valve is closed all the way, then
it is possible that the make-up valve is not tight.
Replace the make-up valve.
3. Check if the secondary heat exchanger is leaking.
4. Also check if the sensor is working properly
pressure and connectors of its contacts.
Another option: opening the plug on the right side
above, in order to enter the combustion chamber
warm air and not
condensation formed in the presostat tubes.