Solenoid valve electromagnetic ev220, danfoss, asco. Electromagnetic gas valve. Gas column solenoid valve Electronic gas valve
Big choice electromagnetic valves used in gas communications. The body of the product is brass, strong and durable. Products have the function of manual cocking and belong to normally closed valves (opens if the stem is cocked and electricity is connected). The manufacturing company is European.
All types of this equipment are available, with flanged and threaded connections.
The proposed products remotely control gas flows, blocking it if necessary (if the product is used in conjunction with a gas detector). Closing will take no more than one second.
Designed for industrial and domestic use.
Versions EVGNС
How the EVGNC valve works
In the absence of voltage, the EVGNС valve is closed, and in the presence of voltage and the stem is cocked, it opens. When the EVGNC valve is operated, for example, with a gas detector, after a gas leak occurs, the alarm relay contacts close, the valve is energized, and the valve shuts off the gas supply. Closing time less than 1 sec. To open the valve, cock it using the cocking rod.
Specifications of gas shut-off valve normally open with manual cocking EVGNС
Overall dimensions of the normally closed gas shut-off valve with manual cocking EVGNС
valve type | Length, mm | Height, mm | Width, mm |
EVGNС1L012 | 66 | 133 | 35 |
EVGNС2L034 | 66 | 133 | 35 |
EVGNС3L1 | 120 | 159 | 95 |
EVGNС4L114 | 160 | 215 | 140 |
EVGNС5L112 | 160 | 215 | 140 |
EVGNС6L2 | 160 | 246 | 140 |
EVGNС0LDN065 | 310 | 355 | 190 |
EVGNС0LDN080 | 310 | 363 | 200 |
EVGNС0LDN100 | 350 | 363 | 220 |
EVGNС0LDN125 | 480 | 464 | |
EVGNС0LDN150 | 490 | 475 | |
EVGNС0LDN200 | 600 | 510 |
PRICE for EVGNC valves
Type | Diameter | Compound | Price in euro | |||||
500 mbar | 6 bars | |||||||
EVGNC1L012 | DN15 | Threaded | 59,0 | 100,0 | ||||
EVGNC2L034 | DN20 | 61,0 | 103,0 | |||||
EVGNC3L1 | DN25 | 95,0 | 161,0 | |||||
EVGNC4L114 | DN32 | 128,0 | 218,0 | |||||
EVGNC5L112 | DN40 | 132,0 | 224,0 | |||||
EVGNC6L2 | DN50 | 186,0 | 316,0 | |||||
EVGNC0LDN065 | DN65 | Flanged | 468,0 | 795,0 | ||||
EVGNC0LDN080 | DN80 | 567,0 | 964,0 | |||||
EVGNC0LDN100 | DN100 | 954,0 | 1623,0 | |||||
EVGNC0LDN125 | DN125 | 1673,0 | 2844,0 | |||||
EVGNC0LDN150 | DN150 | 1701,0 | 2892,0 | |||||
EVGNC0LDN200 | DN200 | 4612,0 | 7840,0 |
Solenoid gas valve is one of the devices pipe fittings, intended for distribution and regulation of the working environment in gas supply systems, as well as on gas pipelines. Home distinctive feature The solenoid gas valve is a remote control, which is carried out by means of electricity supply. An electrical impulse initiates the movement of an electromagnet in a given direction, which in turn sets the movement of the shutter.
Solenoid gas valve device
The working element of a gas solenoid valve is a seat - an opening located inside the body for the passage of the working medium, as well as a shutter. Depending on the model and configuration of the device, the shutter can be made both in the form of a plate and in the form of a piston. Making reciprocating movements, the shutter opens or shuts off the gas supply. It is mounted on a magnetic rod (core), which is connected to an electromagnet. The electromagnet coil itself is installed in the upper part of the body on the outside of the valve.
Gas solenoid valve: principle of operation
The principle of operation of the electromagnetic gas valve is that when electricity is applied to the coil, a magnetic field is created. Under the influence of this field, the electromagnet is drawn into the coil, and thereby sets the direction of movement of the shutter.
During operation, the valve is subjected to two forces - on the one hand it is the force of resistance to the return spring, and on the other hand it is the force of the magnetic field. The latter is regulated by the strength of the electric current - the stronger electricity, the greater the force with which the force of the spring is overcome. Thus, by adjusting the current supply, it is possible to regulate the degree of opening or closing of the electromagnetic gas valve, and, consequently, the supply of the working medium.
When the power is turned off, the valve returns to its original position, which is determined by its design.
Varieties of electromagnetic gas valves
All models of gas solenoid valves that exist today can be divided into three large groups:
Normally open (NO). When the power supply is cut off, the normal open gas valves are in the open position, providing free passage of the working medium.
- Normally closed (NC). Normally closed solenoid valves without power supply come into a closed state, thereby shutting off the flow of gas in a pipeline or any system.
- Universal. Universal gas solenoid valve designed in such a way that it can remain open or closed in the event of a power outage.
As for other differences, here we can highlight solenoid gas valves direct and indirect action. The former assume that the valve plug is actuated only by the movement of the core; the latter use not only the core to move the shutter, but also the force of the working medium, which can significantly save effort during large passages.
Solenoid gas valves also differ in the number of strokes. Currently there are:
Two-way valves with only inlet and outlet. Devices of this type are intended solely for supplying or blocking the working medium into any system.
- Three-way valves with one inlet and two outlets. Such an electromagnetic gas valve can not only pass, but also redirect the gas flow in the system.
- Four-way valves are devices that have four holes - one inlet and three outlets. Like three-way valves, they can redistribute the flow of the working environment, but unlike them, they provide more opportunities for connecting to various systems.
It should be noted that inside each type of electromagnetic gas valves there are many models and modifications of these devices, differing both in size and functionality. For example, according to the operating conditions, some valve models may have special coating resistant to aggressive media.
Where to buy a solenoid gas valve?
Solenoid gas valves are devices that operate on gas pipelines, and their failure can lead to the most backfire. That is why valves must meet the most stringent requirements for their safety and reliability. And this means that you need to purchase them only from a well-established manufacturer.
JSC "Penza Valve Plant" is an enterprise with more than half a century of history. During the operation of the plant, our devices have repeatedly proved their highest quality and unsurpassed reliability. Therefore, if it is necessary to purchase pipeline fittings, we recommend that you pay attention to the products of PAZ OJSC, among which there are various models electromagnetic gas valves.
Solenoid valves KEG-9720 are designed for use in systems remote control gas burners for steam and hot water boilers, heating units, household heating installations and in technological pipeline systems for controlling the flow of gas as a shut-off and control body and a safety body.
Scope of KEG-9720 valves: installation of gas-fired boiler rooms; in the residential sector of public utilities, equipped with stoves, water heaters, heating boilers running on gas.
For connection to the gas pipeline, a thread is made in accordance with GOST 6357-73 or flanges in accordance with GOST 12815-80.
Details of the KEG-9720 valve are made of corrosion-resistant materials (aluminum, stainless steel). The valve seat is protected from contamination by an inlet filter.
The valve is equipped with a system electrical connection with built-in rectifier and ground contact.
For connecting pressure sensors, control devices, pilot burner piping and other items, there is a 1/4” threaded fitting in the valve body.
Working position - an electromagnet upwards.
Main specifications valve KEG-9720
Characteristics |
Values |
Note |
normally closed |
||
Nominal passage Du, mm |
20;25;32; |
|
Opening/closing time, s |
||
Pressure range, bar |
0 - 4 |
DN=20;25;65;80 mm |
Switching frequency, 1/hour |
Du= 20;25;32;40;50 mm |
|
Inclusion resource |
1x106 |
Du= 20;25;32;40;50 mm |
Volume flow, m3/h (by air) |
200 |
At Рin = 4 kgf/cm2 With a difference of 7.6 * 103 Pa |
Supply voltage, V |
||
Power consumption, VA |
35 |
Du= 20;25;32;40;50 mm |
Degree of protection |
||
Temperature environment, °С |
||
Overall dimensions, mm, no more than: LxHxB |
90x165x105 |
Weight, kg, no more |
Execution of KEG-9720 valves
Designation |
Execution |
Note |
Mounting method |
|
IBAL.685181.001-09, -10 |
Rlab.=0.4 MPa |
coupling |
||
IBAL.685181.001-03, -04,-05 |
Rlab.=0.1 MPa |
|||
IBAL.685181.001-06, -07,-08 |
Explosion-proof isp. |
|||
IBAL.685181.001-11, -13 |
Rlab.=0.1 MPa |
flanged |
||
IBAL.685181.001-12, -14 |
Rlab.=0.4 MPa |
Note. Solenoid valves KEG-9720 are supplied both as separate products and as part of security systems (SGG6M, SOU-1, STG-1).
Online application
We guarantee that your data will not be passed on to third parties under any circumstances.
The solenoid valve for water, gas, oil products, which has a shut-off and control design, is actively used in modern industry. The valve allows you to remotely control heating and thermal equipment, as well as gas flows in pipelines. With the use of a gas solenoid valve, the general security systems, with low power consumption, the equipment is highly reliable and long term service with sufficient purity of the fuel (no inclusions of mechanical impurities).
Main types of solenoid valves
- Solenoid shut-off valve for use on pipelines through which only liquid media or gases are transferred. This equipment works as part of air conditioning, ventilation, oil products, gas and steam systems.
- Valves with pneumatic drive.
- Explosion-proof and intrinsically safe valves.
- Devices that allow you to control pneumatic actuators
- valves special purpose(solenoid solenoid valve that work with cryogenic working media, gas stations, vacuum plants).
- Electropneumatic distributors.
The manufacturers presented today create normally closed solenoid valves. In the presence of a manual cocking of the shutter, an automatic overlap occurs, which is triggered when a signal is received on the coil (electromagnet). All fuel solenoid valves are a tool to increase the safety of the facility, since in the presence of malfunctions and the operation of the equipment, they must be assembled.
Our company is actively working on the design and development of new modifications of solenoid valves. Call, contact, we are always ready to provide detailed advice on all questions.
Product of an Italian manufacturer, guarantee of uninterrupted operation of all types gas systems: water heating, heating and their variations. Provides regulation, overlap and direction of gas flows. Has a manual platoon. The maximum values are 6 bar and 500 mbar. The power figures are 9.0 watts. Threaded and flanged versions available. different models quality normally open gas valves.
If the product is used in conjunction with a gas detector, closing by alarm. It will take no more than one second to close.
Suitable for domestic and industrial needs (as part of various gas-consuming systems).
Versions EVGNA
How the EVGNA Valve Works
When not energized, the EVGNA valve is open, and when energized and the stem is cocked, it closes. When the EVGNA valve is operated, for example, with a gas detector, after a gas leak occurs, the alarm relay contacts open, the valve is de-energized and shuts off the gas supply. Closing time less than 1 sec. To open the valve, it is necessary to apply voltage to it, then cock it by pressing the cocking rod.
Specifications of gas shut-off valve normally open with manual cocking EVGNA
Overall dimensions of the normally open gas shut-off valve with manual cocking EVGNA
valve type | Length, mm | Height, mm | Width, mm |
EVGNA1L012 | 66 | 133 | 35 |
EVGNA2L034 | 66 | 133 | 35 |
EVGNA3L1 | 120 | 159 | 95 |
EVGNA4L114 | 160 | 215 | 140 |
EVGNA5L112 | 160 | 215 | 140 |
EVGNA6L2 | 160 | 246 | 140 |
EVGNA0LDN065 | 310 | 355 | 190 |
EVGNA0LDN080 | 310 | 363 | 200 |
EVGNA0LDN100 | 350 | 363 | 220 |
EVGNA0LDN125 | 480 | 464 | |
EVGNA0LDN150 | 490 | 475 | |
EVGNA0LDN200 | 600 | 510 |
PRICES per valve EVGNA
Type | Diameter | Compound | Price in euro | |||||
500 mbar | 6 bars | |||||||
EVGNA1L012 | DN15 | Threaded | 49,0 | 84,0 | ||||
EVGNA2L034 | DN20 | 52,0 | 88,0 | |||||
EVGNA3L1 | DN25 | 75,0 | 128,0 | |||||
EVGNA4L114 | DN32 | 93,0 | 158,0 | |||||
EVGNA5L112 | DN40 | 99,0 | 168,0 | |||||
EVGNA6L2 | DN50 | 151,0 | 256,0 | |||||
EVGNA0LDN065 | DN65 | Flanged | 387,0 | 659,0 | ||||
EVGNA0LDN080 | DN80 | 477,0 | 811,0 | |||||
EVGNA0LDN100 | DN100 | 841,0 | 1430,0 | |||||
EVGNA0LDN125 | DN125 | 1427,0 | 2426,0 | |||||
EVGNA0LDN150 | DN150 | 1465,0 | 2490,0 | |||||
EVGNA0LDN200 | DN200 | 3969,0 | 6747,0 |