Repair Design Furniture

Sterilization boxes. Sterilization equipment dzmo Sterilization box rectangular volume 9 dm keel

STERILIZATION BOXES- containers for placement of dressings, operating clothes, surgical instruments, gloves and other items during their sterilization, delivery to the place of use and subsequent short-term storage (bix). S. to. Allow to create in lay down. - the prof. institutions, a reserve of sterile materials for urgent surgical interventions and contribute to the centralized use of sterilization equipment (see. Scientific organization of labor).

In the second half of the 19th century. in Moscow, G.V. Mendel suggested using zinc boxes for placing dressings in them during sterilization. Later, E. Braatz proposed wire baskets (Braatz boxes) for autoclaving instruments, and A. Diihrssen - cylindrical tin boxes with holes along the perimeter, in the bottom and the lid. K. Schimmelbusch used a four-sided box with a lattice bottom (Schimmelbusch box) for sterilizing materials.

At the present time, round and rectangular S. to., With a filter and without a filter, are used. Their main technical characteristics are shown in the table.

Round S. to. Without a filter (bix) are intended for use in sterilizers (see), which have a predominantly cylindrical sterilization chamber. They consist of a body, a cover and a belt moving along the body (Fig. 1). There are holes in the body and in the belt, which are combined for the period of sterilization (before being placed in the sterilizer). When unloading S. to. From the sterilizer, the belt is shifted, closing the so-called. openings so that sterile instruments and materials in the C. to. do not come into contact with the air of the room. In this case, the sterility of the material remains up to 3 days. The belt is equipped with a tension lock, which excludes its spontaneous movement.

For a longer preservation of the sterility of materials (up to 20 days), S. to. Round type KSKF (Fig. 2) and rectangular type KSPF (Fig. 3) are used. They are supplied with biol. a filter made of textile materials (filter-diagonal, non-woven napkin, bleaching calico, calico, madapolam, etc.), to-rye are attached from the inside of the case and cover.

It is recommended to put a pad (cotton cloth, gauze or other material) on the bottom of the S. to. Before placing materials in it, the moisture accumulating after sterilization will be absorbed into it. Before placing individual items (tools, gloves) in the dressing room, it is better to wrap it with a double layer of gauze and place it loosely (on the edge) in the dressing room. Linen and dressings should be rolled up in flat bags and placed in the dressing room without sealing. also on the edge so that the palm would freely enter between them. When closing the S. to. The lid is locked. The lid should not compress the contents of the C. to. During sterilization, to control the temperature in C. to. Use samples with substances whose melting point is known (sulfur melts at 115 °, benzoic acid at 122 °, etc.). These substances in the form of a powder in vials or test tubes are placed in a C. to. Among the material to be sterilized, and at the end of sterilization it is checked whether the powder has melted or not. Sometimes indicators are added to the powder - safranin, brilliant green, etc., which color them at the moment of melting in the appropriate color. A tag is attached to the lock of the closed lid, which indicates the date of sterilization, the name of the employee who carried out the installation, a list of sterilization objects located in the C. to., And with a centralized sterilization - the department.

Table. MAIN TECHNICAL CHARACTERISTICS OF DOMESTIC STERILIZATION BOXES

Box numbers

External dimensions, mm

Weight (mass), kg

With filter

Without a filter

Diameter (for round), length and width (for rectangular)

With filter

Without a filter

Rectangular

issued

issued

* The diameters of sterilization boxes produced before 1981 are given in brackets.

Bibliography: Vashkov V. I. Means and methods of sterilization used in medicine, M., 1973; Frosin V.N., Tsibikov V. B. and Rabin-k and y B. Ya. Medical sterilizers, M., 1981, bibliogr.

Round sterilization box with filters type KF (Russia) and KSKF (Belarus)

Filter box (type: CF 3, CF 6, CF 9, CF 12, CF 18), and Sterilization Box Round with Filter(type: KSKF 3, KSKF 6, KSKF 9, KSKF 12, KSKF 18) or medical bix for sterilization- absolutely similar in purpose and application, differ slightly in design and manufacturer - intended for placement of medical items and materials in it, such as: dressings, heat-resistant syringes, surgical linen, surgical material and other medical items for the purpose of sterilizing them in steam sterilizers and delivery to the place of use, as well as sterile storage of all contents for 20 days.
Bixes for sterilization (KF sterilization round box with filters) - made of corrosion-resistant, non-magnetic stainless polished steel (ISO 9001), recommended for use in medical technology, are completed with replaceable filters made of cotton cloth (from filter diagonal article 2074/100 GOST 332- 91.)
Composition of sterilization round box with filter (CF):
- Frame
- a pen
- lid
- lock
- filter (2 pcs.)
- clamp
- latch
- earring
- retainer

Filters for sterilization boxes make it possible to sterilize medical items and materials in steam sterilizers under pressure (0.2 ± 0.02) MPa, at a temperature of 132 ± 2 ° C for 20 minutes or under pressure (0.11 ± 0, 02) MPa, at a temperature of 120 ºС for 45 minutes, while the filters are suitable for microbiological filtration of the air during subsequent storage. To replace used filters, the company produces sets of replacement filters for sterilization boxes of all sizes. The set consists of two filters. One package contains 5 sets of filters for boxes of the same size. Replacement filter kits can also be used to replace filters in sterilization round boxes of type KF. Since 2004, filters of the same standard size of KSKF and KF boxes are completely interchangeable!
Sterilization box KF and sterilization box KSKF - during operation, it is prohibited to use without filters!
Bix medical KF has a warranty period of operation - 36 months
Package: The KF box and the KSKF box are sold only assembled, inside the box there are instructions for use (manufacturer's passport) and 2 filters. Sterilization box with filters assembled - packed in an individual packing container (branded cardboard box).
Peculiarities: The sterilization box KF (medical bixes with a filter) manufactured by DZMO JSC (Doschatinskiy plant of medical equipment) does not provide for any rubber seals in its design, since it uses a special technology for rolling sheet metal, and also has 3 metal legs on the base of the body that provide guaranteed clearance for steam passage when boxes are stacked in the sterilizer on top of each other - this is a significant technical advantage over other box manufacturers.

Name KF-3 KF-6 KF-9 KF-12 KF-18
Diameter in mm. 190 (± 5) 250 (± 5) 290 (± 5) 340 (± 5) 390 (± 5)
Height (with legs) in mm 140 (± 10) 160 (± 10) 160 (± 10) 160 (± 10) 190 (± 10)
Nominal volume in dm³ 3 6 9 12 18
Product weight in kg. 0,6 1,0 1,2 1,6 2,0
Dimensions with packaging in mm:
width
length
height

179
179
149

235
235
165

285
285
165

335
335
165

380
380
200

Price in rubles 749,00 1110,00 1415,00 1615,00 1918,00

Purchasing sterilization boxes KF and KSKF note for the presence of: - the original manufacturer's stamp on the Certificate of Conformity - the original corporate brand on the product. Round sterilization boxes KSKF manufactured by JSC "Grodno Trade Machine Building Plant", Belarus
differ from other manufacturers by the presence of a quick-release filter clamp, convenient latches - in the lid and at the bottom of the sterilization box. All products have a Russian Certificate of Conformity, as well as Registration Certificates of the Ministry of Health of Russia, Kazakhstan, Uzbekistan, and the Kyrgyz Republic.

Warranty period: 36 months

Sterilization box KSKF dimensions:

Specifications KSKF-3 KSKF-6 KSKF-9 KSKF-12 KSKF-18
Nominal volume (dm³) 3 6 9 12 18
Diameter in mm, no more 175 245 275 325 390
Height in mm, no more 170 170 190 190 190
Weight in kg, no more 0,75 1,15 1,45 1,9 2,45
Filter diameter (mm) 110 135 155 175 175
Number of locks 1 2 2 2 2
Price, RUB

Replaceable filter for boxes KF and KSKF

Filter for sterilization boxes KF and KSKF - made of dense cotton fabric specially designed for this purpose - filter-diagonal article 2074/100 GOST 332-91. Filter cloth
it is produced by weaving of an equilateral four-thread twill. The filters are reusable and can be easily disposed of by incineration, guaranteed to withstand at least 60 sterilization cycles - they are consumable replaceable materials, therefore, filters of all sizes can be purchased separately. A set of filters for KF and KSKF boxes consists of 2 pieces. Filters for sterilization boxes KSKF are installed in special places on the bottom and lid of the box. The KF filter is placed under the clamp and snapped into place with a retainer (KSKF) or under a screw retainer (KF). Spare filter kits can also be used to replace filters in sterilization round filter boxes. Since 2004, filters of the same standard size of KSKF and KF boxes are interchangeable.

If the universal filter is larger than the seat on the sterilization box, its edges (excess) are cut with ordinary scissors, as well as the hole for the fastening (the filter is folded in half in half and the tip is cut off).

People also buy with this product:

Round sterilization boxes with filters

KF-3/6/9/12/18

Sterilization boxes KF-3/6/9/12/18 are intended for placement of medical items and materials in it for the purpose of sterilization in steam sterilizers, further storage and delivery to the place of use.

Principle of operation boxes is based on the penetrating ability of steam through filters to the inside of boxes and the ability of filters to microbiological filtration of air.

Basic bridles and details

The boxes consist of hinged lid enclosures, which is tightly closed with latches. The hinge joint allows the lid to open as fully as possible.

The cover is equipped with pen to carry the box.

On the base of the case there are legs

Boxes are completed two replaceable filters from filter diagonal art. 2074 in accordance with GOST 332, which are fixed in the lid and at the bottom, on the inside of the box, using clamps.

The period of preservation of sterility in the box after sterilization is up to 20 days according to MU-287-113.

The service life of filters with one sterilization per day is 1 month.

Replacement filters from other manufacturers cannot guarantee sterility.

Specifications:

* overall diameter is indicated taking into account hinge and lock

** overall height is indicated from the top of the lid for the bottom, taking into account the length of the legs

Advantages:


2. There are legs on the base of the box body, which provide a guaranteed clearance for steam passage when stacking boxes with a steam sterilizer on top of each other.

Sterilization boxes KSPF-9 / KSPF-18 intended for placement of medical products made of corrosion-resistant metals, glass, rubber, latex, certain types of plastics, textile products, as well as dressing and suture materials, for the purpose of sterilization in steam sterilizers, delivery to the place of use in a sterile state and storage after sterilization within a specified period. They are used in hospitals and other medical institutions.
Principle of operation
the box is based on the penetrating ability of steam through the filters to the inside of the box and the ability of the filters to microbiological filtration of the air environment.
Main assemblies and details
are made of stainless steel.
The body provides pens for carrying the box.
On the base of the case there are legs providing a guaranteed gap for steam passage when the boxes are stacked in the sterilizer on top of each other.
Lid
- removable, equipped with a silicone sealing gasket, securely fixed to the body with two locks.
The design of the box provides for the possibility of installation fillings to detect the fact of opening the box.
Boxes are completed replaceable filters from filter diagonal art.2074 in accordance with GOST 332, which are fixed in the lid and on the bottom, from the inside of the box, using clamps.
Sterility retention period
in a box after sterilization up to 20 days according to MU-287-113.
Service life of filters
within 1 month with 1 sterilization per day.

Specifications:

Advantages:

1. The boxes are made of high quality non-magnetic stainless steel.
2. The rectangular shape of the boxes allows them to be installed as tightly as possible in the steam sterilizer.
3. The presence of a sealing silicone gasket on the lid guarantees a tight fit of the lid to the box body.
4. The handle for carrying the box is equipped with a silicone tube, which protects the medical personnel from the possibility of getting burned.
5. On the base of the box body there are legs that provide a guaranteed clearance for steam passage when stacking boxes with a steam sterilizer on top of each other.

Disinfection boilers

Designed for instrument disinfection by boiling in distilled water. The boiler is used in medical institutions .

Principle of operation The boiler is based on electric heating and boiling of water in a container with a tool placed in it.

Frame boiler, tray and lid are made of stainless steel. The main parts and assemblies of the boiler are made of corrosion-resistant materials.

Control block consists of an input box with a power cord, fuses, an indicator of inclusion in the network and the heating device itself. The power cord is equipped with a two-pole earthing plug.

The body is equipped with a perforated stainless steel tray for placing disinfection objects. The tray is removed from the body using plastic grips.

When connected to the network, the indicator lights up and the water starts heating.

The boiler turns off automatically when boiling or lack of water.

The boiler is supplied in corrugated cardboard packaging.

Specifications:

Advantages:

1. The boiler is made of high quality non-magnetic stainless steel, 1 mm thick.
2. The boiler is supplied with a perforated tray.
3. The tray is removed from the boiler using plastic grips, which protects the medical staff from the possibility of burns.