Repair Design Furniture

Mini pump drainage mini orange aspen. Drainage pumps for Aspen Mini and Maxi Orange air conditioners. Drainage pump Aspen Mini Orange

Drainage pump Aspen Mini Orange

Specifications

Description

The drainage pump is part of the split system, which is responsible for pumping out the condensate created by the indoor unit. Without it, the water will stagnate, which will cause unpleasant odors, overflow of liquid will lead to the appearance of dampness on the walls, the formation of fungus.

The Aspen Mini Orange pump can be installed above a raised ceiling, in a plastic conduit or in indoor unit split systems. Each of the installation methods has its own advantages and disadvantages; it is selected depending on the characteristics of the equipment and its location.

The set with the Mini Orange pump is supplied with 2 types of tanks: for installation in the drain pan of the system and for connection to the drain pipe of the pan. The use of this or that type of container depends on the design features of the air conditioner. If you connect the reservoir to the branch pipe and install the pump in the indoor unit of the split system, the device will be able to raise the liquid to a height of 8 meters.

Aspen Mini Orange pump complete set:

  • pump; reservoir, consisting of a housing, a sensor cable, a float with a magnet, a cover, a mesh filter;
  • submersible tank;
  • vinyl tube with a diameter of 6 mm and a length of 150 mm;
  • vinyl tube with a diameter of 6 mm and a length of 1,500 mm;
  • drainage tube;
  • socket for 6 outputs;
  • 4 clips 30 x 0.36 cm;
  • 2 clip 14 x 0.36 cm;
  • 2 pile adhesive Velcro strips.

Installation procedure for the Mini Orange pump:

A chamber with a magnet float is connected to the drain hose of the indoor unit, under the bath. It will serve as a water level sensor.
The pump is installed above the indoor unit, connects to it drain pipe with a float chamber. Another tube coming out of the pump connects to the drain. The device works according to a simple principle: the chamber is filled with water, the float rises and closes the contacts, including the pump. It pumps out liquid and stops when the float gives another signal.

Average customer rating: (2)

0
0
0
0
0
2

Delivery in Moscow and the nearest Moscow region

Delivery is carried out by our courier service... Cost of delivery:

  1. in Moscow - 250 rubles
  2. outside the Moscow Ring Road - 250 + 30 rubles per km

Delivery in Moscow and Moscow region is carried out daily from 09:00 to 20:00. Delivery on weekends and holidays.

We can deliver your order urgently - if your order is made before 13.00, we delivered it on the same day until 22.00, while the cost of delivery will increase by 30%

Estimated delivery time:

  1. in Moscow and the Moscow region from 1 to 3 days
  2. across Russia according to the working conditions of the shopping mall.

Free delivery is carried out within the Moscow Ring Road only for goods marked with the appropriate flag!

Delivery all over Russia

We deliver to the region in two ways:

  1. Request an invoice for payment
  2. You pay the bill (delivery to the shopping center is calculated at the same rates as delivery in Moscow and Moscow region)
  3. We deliver your order to the TC office and transfer it for delivery to your region
  1. You choose transport company(TC)
  2. Request an invoice for payment
  3. Pay the bill
  4. A representative of the shopping mall comes to our warehouse and picks up your order
  5. In this case, you do not pay for our services for the delivery of the ordered goods.

Delivery provisions

  1. Upon delivery, the buyer has the right to check in the presence of the forwarding courier appearance goods and completeness of delivery.
  2. Verification and payment of the order must be completed within 20 minutes.
  3. The forwarder is not authorized to give any advice on the technical parameters of the goods, their cost, etc.
  4. Payment for the goods upon delivery is carried out only in Russian rubles.
  5. Payment is made only in office and residential premises, or in the car of the forwarder.
  6. Delivery by car is carried out to the entrance of the house specified in the order form. Delivery of goods to the apartment (office) is not carried out.
  7. Upon delivery to a territory with a paid entry, the buyer compensates the cost of entry. In other cases, delivery is carried out only to the place of paid entry.
  8. Delivery is a separate service. It is not considered an integral part of the goods purchased by the Buyer. The delivery service ends when the customer receives the goods.
  9. Claims to the quality of the purchased goods arising after its receipt are considered in accordance with the Law of the Russian Federation "On Protection of Consumer Rights" and the company's warranty obligations.
  10. After you fill in all the documents, the delivery service is considered completed. The purchase of goods with delivery does not give the Buyer the right to demand a repeated delivery of the goods in the event of a need for warranty service or replacement, and does not provide an opportunity to carry out warranty service or replacement of goods by visiting the Buyer. The purchase of goods with delivery does not imply the possibility of a refund of the cost of the delivery of goods in the event that the Buyer is entitled to a refund for the goods in accordance with the "Law on the Protection of Consumer Rights".

ASPEN MINI ORANGE pump

INCLUDED price RUB 4800.00

1. Pump Mini Orange

2. The tank consists of:

A. cover and sensor cable

B. float with magnet

C. filter mesh

d. tank body

3. Submersible tank

4. Vinyl tube: length 15 cm,

Diameter 6 mm

5 . Input drainage tube

6. Vinyl tube: length 1.5m,

Diameter 6 mm

7. 1 6-pin socket

8. Clips 300mm x 3.6mm (4 pcs)

9. Clips 140mm x 3.6mm (2 pcs)

10. Self-adhesive pile

Velcro tape (2 pcs)

* NOTE: You will need several

meters of vinyl tube outer diameter

rum 9 mm and inner diameter 6 mm

SPECIFICATIONS

Power supply 220-240 V - 16 W Water flow rate 14 l / h at
1 phase 50/60 Hz zero height
3 A signal wires not under Maximum water temperature 40 С
voltage, N.O. (fine Maximum recommended height
open) N.C. (fine lifting 8 m
closed) Noise level: 23 dB (A) - distance 1 m
Long running time Discharge tube: int. diameter 6 mm
Hall effect water with high CE mark
the degree of security Thermal protection
Fully sealed

PERFORMANCE SCHEDULE

SECURITY

WARNING: Pump Mini orange Do not run the pump without water.
only pumps out water. make sure the magnet is in
Attention! There is a risk of electric shock the float is at the top.
tric current. This pump is not intended Be sure to check that the reservoir is
for use in swimming pools and is in a horizontal position.
coastal areas. The pump is perfect for practically
Insulating electrical contacts for all industrial, residential
must fit all and office space. However, not
the requirements imposed on it. it is recommended to use the pump in
Make sure the pump is de-energized before especially dusty conditions and
installation and service. work with oily substances.
If electrical wire damaged, Applicable for use only
then it should be replaced with the same indoors.
or similar. Doesn't work underwater.

PREVENTION OF AIR CONCLUSION

Place the water drain pipe above the water level in the indoor unit and insert its end into the wider drain pipe.

1. False ceiling 2. End drain pipe 3. Water level in the sump 4. Air brake 5. Top of the anti-formation tube air congestion

MOUNTING

1 Select the type of tank


2 Make sure the float in the tank is magnetically up, the filter is in place and the tank lid is tightly closed.

4 Slide the airlock tube over the nipple on the reservoir lid.

5 Install the pump unit behind false ceiling where possible.

1. False ceiling 2. Evaporator coil 3. Condensate drip tray 4. Vinyl tube 5. Plastic box

6

7 Pay attention to the direction of movement of the water

8 Slide a 9mm outside diameter and 6mm inside diameter tubing over the reservoir and pump. Secure the joints with clamps. Make sure the length of the tube does not exceed 2 m.

9

10 In order to emergency shutdown of the air conditioner in the event of a pump malfunction, in the air conditioner must be provided with a built-in emergency switch.
Note: This manual is an example of how the pump can be installed and is for reference only. All pumps must be installed by qualified personnel.


11 To check pump operation, pour water into the evaporator pan. Make sure the connections are tight

The best-selling device for removing condensate liquid from household, semi-industrial, industrial climatic equipment is a drainage pump for the Aspen Mini Orange air conditioner.

general characteristics

The Aspen Orange drainage pump belongs to the separate type drainage systems. It differs from other similar devices in design features. Separate, they consist of several parts: a storage tank for collecting condensate and a pump, communicating with each other using a branch pipe. Some models may have a separate control unit.

Due to their separate design, the systems have several hidden options installations both in the innermost block of the cooling equipment and outside it. This feature makes separate pumps one of the most popular for the removal of accumulated condensate from domestic, industrial climatic installations.

Functioning principle

The Aspen Orange drainage pump in its basic configuration is equipped with two reservoirs at once for collecting liquid (submersible and separately mounted). The use of these containers depends on the design features of the specific cooling equipment.

The tanks are installed in the pallet itself and inside the air conditioner unit. The pump pump can be installed in the indoor unit itself or outside it in ceiling space, wall niches, communication boxes, etc. After connection, the branch devices are capable of pumping excess fluid to a height of 10 m to 20 m (depending on the model).

Each tank has a float to determine the liquid level in it. When the float reaches a certain height, the contacts close, a signal is sent to turn on the drainage system. The device will drain the accumulated condensate until a new signal is received from the level sensor.

Equipped with overfill protection, which allows them to be operated even in a non-standard situation.

Scope of application - household, household, industrial climatic devices.

The Maxi Orange drainage pump is distinguished by its high power, the height of the condensate rise, the minimum level of operating noise. This allows it to be installed in medical, public, domestic and industrial premises.

Can be mounted in large blocks to provide additional power. Suitable for use in powerful climatic devices, removing large amounts of condensate at a distance of up to 100 m horizontally.

At the same time, rather small dimensions and weight allow the system to be secretly mounted in compact spaces, small-sized rooms.

Drainage pump Aspen Mini Orange

The drainage pump Mini Orange stands out among its counterparts with its compact size and good performance. This main advantage allowed her to become the best-selling drainage system in the world. Installation in small-sized air conditioning systems is possible, in conditions of limited space. Possesses more low level noise compared to Maxi Orange, does not require additional participation in its work.

At the same time, it is distinguished by reliability, high quality, ease of installation and further service.

Installation of Aspen Orange systems

Installation is clearly presented in the video

Benefits of Aspen systems

They have a number of advantages over similar devices:

  • almost silent level of work;
  • small dimensions, allowing the system to be installed in the indoor unit of climatic equipment or communication niches, even in limited conditions, without violating the aesthetics of the space of an apartment or office;
  • optimal combination of compact size with the production capacity of drainage systems;
  • high rates of removal of condensed liquid from climatic systems;
  • condensate lifting height up to 2 m;
  • absolute sealing of drainage systems;
  • foreseen thermal protection Aspen Orange;
  • the presence of an anti-siphon design;
  • availability of the plug-and-play concept;
  • easy access to the system in the process of further service and care;
  • acceptable price.

In many respects, these devices are recognized as one of the best in the segment of condensate drainage devices in climatic, refrigeration equipment... Thanks to its design features, small size, high performance power, ease of connection and maintenance, high-quality equipment, a variety of related accessories and reasonable price Aspen Orange is in high demand among consumers. Its reliability, efficiency of work, high quality these systems have been proven over many years of comfortable use.

Friends! More interesting materials:

Ouch! There are no materials yet (((. Browse the site yet!