The geyser NEVA 3208 is convenient, simple and reliable. Despite the venerable age of most of the exploited specimens, they quite regularly cope with their responsibilities for heating water. But sometimes you want to clarify something in the instruction manual. And this is where the problem comes in.

The original manual is most often lost, but the user manual is downloaded from the Internet. Neva-3208 impossible. More modern dispensers Neva 4000, 5000 series, Neva Lux 6000, boilers Neva Lux 8000 series - please, but there are no instructions for Neva 3208.

The search comes across only fraudulent sites requiring a cell phone number, but even there there is no instruction - one file name. It is easy to check this by trying to find a file on such a site with a deliberately non-existent name - for example, “ qwerrasdfgfgh - $% # [email protected]$ ". He will find it, and even say that it has been downloaded several thousand times! I hope that you do not fall for such tricks and do not enter your phone number on suspicious sites. And the instruction manual for the Neva-3208 geyser can be found here.

HOUSEHOLD GAS WATER FLOW HEATING APPLIANCE

NEVA-3208 GOST 19910-94

NEVA-3208-02 GOST 19910-94

OPERATING MANUAL 3208-00.000-02 OM

Dear customer!

When buying a device, check the completeness and presentation of the device, and also require the dealer to fill out coupons for warranty repairs

Before installing and operating the device, you must carefully read the rules and requirements set forth in this operation manual, the observance of which will ensure long-term trouble-free and safe operation of the water heater.

Failure to install and operate properly may result in an accident or damage to the device.

1. GENERAL INSTRUCTIONS

1.1. Household gas flowing water heating apparatus "NEVA-3208" (NEVA-3208-02) VPG-18-223-V11-P2 GOST 19910-94, hereinafter referred to as "apparatus", is intended for heating water used for sanitary purposes (washing dishes , washing, bathing) in apartments, cottages, country houses.

1.2. The device is designed to operate on natural gas in accordance with GOST 5542-87 with a lower calorific value of 35570 +/- 1780 kJ / m3 (8500 +/- 425 kcal / m3) or liquefied gas in accordance with GOST 20448-90 with a lower calorific value of 96250 +/- 4810 kJ / m3 (23000 +/- 1150 kcal / m3).

At the factory, the device is adjusted to a specific type of gas indicated on the nameplate on the device and in the "Certificate of Acceptance" section of this manual.

1.3. Installation, assembly, owner briefing, preventive maintenance, troubleshooting and repairs are carried out by operating organizations of the gas industry or other organizations licensed for this type of activity. Section 13 must be marked and stamped by the organization that installs the apparatus.

1.4. Checking and cleaning the chimney, repairing and monitoring the water supply system are carried out by the owner of the device or by the house management.

1.5. The owner is responsible for the safe operation and maintenance of the device.

2. TECHNICAL DATA

2.1. Rated thermal power 23.2 kW

2.2. Nominal heating capacity 18.0 kW

2.3. Rated thermal power of the pilot burner no more than 0.35 kW

2.4 Nominal pressure of natural gas 1274 Pa (130 mm H2O)

2.5 Nominal pressure of LPG 2940 Pa (300 mm H2O)

2.6. Nominal consumption of natural gas is 2.35 cubic meters. m / hour.

2.6. The nominal consumption of liquefied gas is 0.87 cubic meters. m / hour.

2.7. Efficiency not less than 80%

2.8. Supply water pressure for normal operation of the apparatus 50 ... 600 kPa

2.9. Water consumption when heating at 40 degrees (at rated power) 6.45 l / min

2.10. Gas combustion products temperature not less than 110 degrees

2.11. Chimney vacuum not less than 2.0 Pa (0.2 mm water column), not more than 30.0 Pa (3.0 mm water column)

2.12. Ignition of the "NEVA-3208" apparatus is piezoelectric, of the "NEVA-3208-02" apparatus - with a match

2.13. Overall dimensions of the device: height 680 mm, depth 278 mm, width 390 mm

2.14. Apparatus weight no more than 20 kg

3. DELIVERY SET

3208-00.000 Neva-3208 or NEVA-3208-02 apparatus 1 pc.

3208-00.000-02 RE Operation manual 1 copy

3208-06.300 Package 1 pc.

3208-00.001 Handle 1 pc.

Wall mounting hardware 1 set

3103-00.014 Gasket 4 pcs.

3204-00.013 Bushing 1 pc.

4. SAFETY PRECAUTIONS

4.1. The room where the device is installed must be constantly ventilated.

4.2. To avoid a fire, do not put flammable substances and materials on the device or hang near it.

4.3. After stopping the operation of the device, it is necessary to disconnect it from the gas supply source.

4.4. In order to avoid defrosting the device in winter (when installed in unheated rooms), it is necessary to drain the water from it.

4.5. In order to avoid accidents and breakdown of the device, consumers are FORBIDDEN:

a) independently install and start the device into operation;

b) allow children to use the device, as well as persons who are not familiar with this operation manual;

c) operate the device on gas that does not correspond to the one indicated on the plate on the device and the "Certificate of Acceptance" of this manual;

d) close the grate or gap in the lower part of the door or wall, intended for the flow of air necessary for the combustion of gas;

e) use the device in the absence of draft in the chimney;

f) use a faulty device;

g) independently disassemble and repair the device;

h) make changes to the design of the apparatus;

i) leave the working apparatus unattended.

4.6. During normal operation of the device and with a working gas pipeline, the smell of gas should not be felt in the room.

If you smell gas in the room, IT IS NECESSARY:

a) turn off the device immediately;

b) close the gas cock located on the gas pipeline in front of the apparatus;

c) thoroughly ventilate the room;

d) immediately call the emergency service of the gas industry by phone. 04.

Until the gas leak is eliminated, do not carry out any work related to sparking: do not light a fire, do not turn on or off electrical appliances and electric lighting, do not smoke.

4.7. If an abnormal operation of the device is detected, it is necessary to contact the gas service and, until the malfunctions are eliminated, do not use the device.

4.8. When using a faulty device or if the above operating rules are not followed, an explosion or poisoning with gas or carbon monoxide (carbon monoxide) in the products of incomplete combustion of gas may occur.

The first signs of poisoning are: heaviness in the head, palpitations, tinnitus, dizziness, general weakness, then nausea, vomiting, shortness of breath, impaired motor functions may appear. A burnt-out person may suddenly lose consciousness.

To provide first aid, it is necessary: ​​take the victim into fresh air, unfasten the clothing that is restricting breathing, let the ammonia smell, cover it warmly, but do not let him fall asleep and call a doctor.

If there is no breathing, immediately take the victim to a warm room with fresh air and perform artificial respiration, without stopping it until the doctor arrives.

5. STRUCTURE AND OPERATION OF THE APPARATUS

5.1. Device device

5.1.1. The apparatus (Fig. 1) of the wall type has a rectangular shape, formed by a removable cladding 7.

5.1.2. All the main elements of the apparatus are mounted on a frame. On the front side of the cladding are located: handle 2 for controlling the gas valve, button 3 for switching on the solenoid valve, viewing window 8 for observing the flame of the pilot and main burners.

5.1.3. The apparatus (Fig. 2) consists of a combustion chamber 1 (which includes a frame 3, a gas outlet 4 and a heat exchanger 2), a water-gas burner unit 5 (consisting of a main burner 6, a pilot burner 7, a gas valve 9, a water regulator 10, a valve electromagnetic 11) and tube 8, designed to turn off the water heater in the absence of draft in the chimney.

NOTE: Due to the fact that OJSC continues to work on further improvement of the device design, the purchased device may not completely coincide in some elements with the description or image in the "Operation Manual".

5.2. Description of the device

5.2.1. Gas through the branch pipe 4 (Fig. 1) enters the solenoid valve 11 (Fig. 2), the switch button 3 (Fig. 1) of which is located to the right of the gas valve switch knob.

5.2.2. When you press the solenoid valve button and open "(to the" Ignition "position) (Fig. 3) the valve, the gas flows to the ignition burner. The thermocouple, heated by the flame of the pilot burner, transmits EMF to the valve solenoid, which automatically keeps the valve disc open and provides gas access to the gas cock.

5.2.3. When knob 2 (Fig. 1) is turned clockwise, gas valve 9 (Fig. 2) carries out the sequence of turning on the ignition burner to the "Ignition" position (see Fig. 3), gas supply to the main burner in the "Appliance on" position ( see fig. 3) and adjusts the amount of gas flowing to the main burner within the "high flame" - "low flame" positions (see fig. 3) to obtain the desired water temperature. In this case, the main burner lights up only when water flows through the device (when the hot water tap is opened).

5.2.4 The device is turned off by turning the control knob counterclockwise to the stop, while the main and pilot burners are instantly extinguished. The valve of the electromagnetic plug will remain open until the thermocouple cools down (10 ... 15 s).

5.2.5. To ensure smooth ignition of the main burner, an ignition retarder is provided in the water regulator, which works as a choke when water flows out of the supra-membrane cavity and slows down the movement of the membrane upward, and, consequently, the ignition speed of the main burner.

The device is equipped with safety devices that ensure:

  • gas access to the main burner only with a pilot flame and water flow
  • shutting off the gas valve to the main burner in case of extinguishing of the pilot burner or cessation of water flow,
  • shutdown of the main and pilot burners in the absence of draft in the chimney.

1 - branch pipe, 2 - handle; 3 - button: 4 - gas supply pipe; 5 - hot water outlet, 6 - cold water inlet; 7 - facing, 8 - observation window

Figure 1. Apparatus water-heating flow-through gas household

1 - combustion chamber; 2 - heat exchanger; 3 - frame; 4 - gas outlet device; 5 - water and gas burner unit; 6 - main burner; 7 - pilot burner; 8 - thrust sensor tube; 9 - gas tap: 10 - water regulator; 11 - electromagnetic valve; 12 - thermocouple; 13 - piezo ignition (NEVA-3208); 14 - plate.

Figure 2. Apparatus water-heating flow-through gas household (without lining)

Figure 3. Positions of the gas cock control knob

6. INSTALLATION PROCEDURE

6.1. Installing the device

6.1.1. The device must be installed in kitchens or other non-residential premises in accordance with the Gasification Project and SNiP 2.04.08.87

6.1.2. Installation and assembly of the apparatus must be carried out by the operating organization of the gas economy or other organizations licensed for this type of activity.

6.1.3. The device is hung with holes (on the frame) on a special bracket mounted on the wall. The mounting holes of the device are shown in Figure 4. It is recommended to install the device so that the viewing window 8 (see Figure 1) is at the consumer's eye level.

6.1.4. Connecting dimensions of pipelines for gas inlet, water inlet and outlet, flue gas outlet through the flue pipe are shown in Figure 1

6.2. Water and gas connection

6.2.1 Connection should be made with pipes with DN 15 mm. When installing pipelines, it is recommended to first connect to the water inlet and outlet, fill the heat exchanger and the water system with water, and only then connect to the gas inlet. The connection should not be accompanied by mutual tension of pipes and parts of the apparatus in order to avoid displacement or breakage of individual parts and parts of the apparatus and violation of the tightness of the gas and water systems.

6.2.2. After installing the device, the places of its connections with communications should be checked for tightness. Checking the tightness of the joints of the water inlet and outlet is carried out by opening the shut-off valve (see Fig. 4) of cold water (with the water taps closed). Leakage at the joints is not allowed.

Check the tightness of the gas inlet connection by opening the common valve on the gas pipeline with the device handle closed ("Device off" position). The check is carried out by soaping the joints or using special devices. Gas leakage is not allowed.

6.3. Installation of a chimney for the removal of combustion products

The apparatus must be provided with a system for the removal of combustion products from the apparatus outside the building. The flue pipes must meet the following requirements:

  • must be sealed and made of non-combustible and corrosion-resistant materials, such as: stainless steel, galvanized steel, enamelled steel, aluminum, copper with a wall thickness of at least 0.5 mm;
  • the length of the connecting pipe should not be more than 3 m, the pipe should not have more than three turns, the slope of the horizontal section of the pipe should be at least 0.01 towards the water heater;
  • the height of the vertical part of the pipe (from the water heater to the axis of the horizontal section) must be at least three diameters;
  • the inner diameter of the flue pipes must be at least 125 mm.

6.3.3. The connection between the appliance and the flue pipe must be tight. It is recommended to install the pipe according to the diagram in Figure 5.

6.4. After installation, assembly and tightness test, the operation of the safety automation must be checked (clauses 5.2.5 and 5.2.6.).

Figure 4. Installation diagram of the device

1 - flue pipe; 2 - branch pipe; 3 - heat-resistant sealant

Figure 5. Connection diagram of the flue gas pipe

7. ORDER OF WORK

7.1. Turning on the device

7.1.1. To turn on the device, it is necessary (see Fig. 4)

a) open the common valve on the gas pipeline in front of the device;

b) open the cold water shut-off valve (in front of the device);

c) set the handle of the device to the "Ignition" position (see Fig. 3),

d) press the button of the solenoid valve 3 (see Fig. 1) and repeatedly press the piezo ignition button 13 (see Fig. 2) (or bring the lighted match to the ignition burner) until a flame appears on the ignition burner;

e) release the solenoid valve button after turning it on (after no more than 60 s), while the ignition burner flame should not go out.

CAUTION: to avoid burns, do not bring your eyes too close to the viewing window.

At the first ignition or after a long period of non-use of the device, in order to remove air from the gas lines, repeat the indicated operations for the items d and e.

f) open the gas valve to the main burner, for which the handle of the gas valve should be turned to the right as far as it will go ("Large flame" position). In this case, the pilot burner continues to burn, but the main burner has not yet ignited.

g) open the water tap, and the main burner should ignite. Adjustment of the degree of water heating is made by turning the knob of the device within the positions "Large flame" - "Small flame" or by changing the flow rate of water passing through the device.

7.2. Turning off the device

7.2.1. At the end of use, you must turn off the device, observing the following sequence:

a) close the water taps (see Figure 4);

b) turn knob 2 (see Fig. 1) to the "Device off" position (counterclockwise until it stops);

c) close the common valve on the gas pipeline;

d) close the cold water shut-off valve.

8. MAINTENANCE

8.1. Regular care, inspection and maintenance are essential to ensure long-term trouble-free operation and maintain the performance of the machine. Care and inspection are performed by the owner of the device.

Maintenance is carried out at least once a year by gas service specialists or other organizations licensed for this type of activity.

8.2.1. The device should be kept clean by regularly removing dust from the upper surface of the device and wiping the casing first with a damp and then dry cloth. In case of significant contamination, first wipe the casing with a damp cloth dampened with a neutral detergent and then with a dry cloth.

8.2.2. Do not use heavy duty detergents containing abrasive particles, gasoline or other organic solvents to clean the surface of the cladding and plastic parts.

8.3. Inspection

Before each switching on of the device, it is necessary:

a) check the absence of combustible objects near the apparatus;

b) check for gas leakage (by characteristic smell) and water leakage (visually);

c) check the serviceability of the burners by the combustion pattern:

the flame of the pilot burner must be elongated, not smoky and reach the main burner (a deviation of the flame sharply upward indicates clogging of the air supply ducts to the burner);

the main burner flame must be blue, steady and free of yellow smoky tongues, indicating contamination of the outer surfaces of the nozzles and inlets of the burner sections.

In the event of gas and water leaks, as well as burner malfunctions, it is necessary to repair and maintain the device.

8.4. Maintenance

8.4.1. During maintenance, the following work is performed:

  • cleaning and flushing the heat exchanger from scale inside the pipes and from soot outside;
  • cleaning and flushing of water and gas filters;
  • cleaning and flushing the main and pilot burners;
  • cleaning and lubricating the tapered surface of the plug and the gas valve opening;
  • cleaning and lubrication of seals and rods of water and gas blocks;
  • checking the tightness of the gas and water systems of the apparatus;
  • checking the operation of the safety automation, including the draft sensor, for which it is necessary to remove the flue pipe (see Fig. 1), turn on the device and, with the gas cock fully open and the maximum water flow rate, close the device branch pipe with a metal sheet. After 10 ... 60 seconds, the device should turn off. After checking, install the flue pipe according to figure 5.

Maintenance work is not covered by the manufacturer's warranty.

9. POSSIBLE FAULTS OF THE DEVICE NEVA 3208 AND METHODS OF THEIR ELIMINATION

Fault name

Probable cause

Elimination methods

Ignitor hardly ignites or does not ignite at all

The presence of air in gas communications.

See clause 7.1 Switching on the device

Clogged pilot nozzle

Replace LPG cylinder

When the solenoid valve button is released (after a control time of 60 s), the igniter goes out.

The flame of the pilot burner does not heat the thermocouple

Call the gas service

Thermocouple electrical circuit is broken - solenoid valve

Check the contact of the thermocouple with the solenoid valve (if necessary, clean the contacts)

Check the tightening of the thermocouple connection with the solenoid valve, while remembering: the tightening force should ensure reliable contact, but should not exceed 1.5 Nm (0.15 kg-m) in order to avoid the failure of these units.

Failed electromagnetic plug or thermocouple

Call the gas service

The main burner does not ignite or is difficult to ignite when opening the hot water tap.

Insufficient opening of the gas valve on the apparatus or the common valve on the gas pipeline

Turn the handle of the device to the "Big flame" position and fully open the common valve on the gas pipeline

Low gas pressure

Call the gas service

Low tap water pressure

Temporarily do not use the device

The water filter is clogged, the membrane is torn, or the water block plate is broken

Call the gas service

The main burner does not go out when the hot water tap is closed

Jammed stem of gas or water block

Call the gas service

The flame of the main burner is sluggish, elongated, with yellow smoky tongues

Dust deposits on the nozzles and internal surfaces of the main burner

Call the gas service

After a short time of operation, the device turns off spontaneously

No draft in the chimney

Clean the chimney.

The supply of liquefied gas in the cylinder has run out

Replace LPG bottle.

The handle of the valve plug is turned with considerable effort

Drying out the grease

Call the gas service

Ingress of contamination

Call the gas service

Low water consumption at the outlet of the apparatus with normal water pressure in the pipeline

Limescale in the heat exchanger or in the hot water outlet

Call the gas service

Insufficient water heating

High water consumption

Deposition of soot on the fins of the heat exchanger or scale in the tubes of the heat exchanger

Call the gas service

During the operation of the device, there is an increased noise from the flowing water

High water consumption

Adjust the water flow to 6.45 l / min.

Misaligned gaskets in the water block connection

Correct misalignment or replace gaskets.

The main burner is ignited with a "pop" and the release of the flame from the casing window

The flame of the ignition burner is small or deviates sharply upward and does not reach the main burner (the nozzle is clogged or the air supply channel to the igniter is clogged with dust, the groove on the valve plug is partially clogged with grease, low gas pressure)

Call the gas service

Ignition retarder does not work

Call the gas service

The igniter does not ignite from the piezo ignition (it ignites normally from a match)

There is no spark between the spark plug and the igniter

Check the connection of the wires of the piezoelectric generator to the candle and to the body of the device.

Weak spark between spark plug and igniter

Set a 5 mm gap between the spark plug electrode and the igniter.

10. STORAGE RULES

10.1. The device must be stored and transported only in the position indicated on the handling signs.

10.2. The device should be stored in a closed room that guarantees protection against atmospheric and other harmful influences at an air temperature from -50 ° C to + 40 ° C and a relative humidity of not more than 98%.

10.3. When the device is stored for more than 12 months, the latter must be preserved in accordance with GOST 9.014

10.4. The openings of the inlet and outlet pipes must be closed with plugs or plugs.

10.5. Every 6 months of storage, the device must undergo a technical inspection, during which the absence of moisture and dust clogging of the units and parts of the device is checked.

10.6. Apparatus should be stacked in no more than five tiers when stacked and transported.

11. CERTIFICATE OF ACCEPTANCE

Household gas flowing water heating apparatus. NEVA - 3208 complies with GOST 19910-94 and is recognized as fit for use

12. WARRANTY OBLIGATIONS

The manufacturer guarantees the trouble-free operation of the device in the presence of design documentation for the installation of the device and if the consumer observes the rules of storage, installation and operation established by this "Operation Manual".

The warranty period for the device is 3 years from the date of sale through a retail network; 3 years from the date of receipt by the consumer (for off-market consumption);

12.3. Warranty repair of the device is carried out by gas services, the manufacturer or other organizations licensed for this type of activity.

12.4. Average service life of the device is not less than 12 years.

12.5. When purchasing a device, the buyer must receive the "Operation Manual" with the mark of the store about the purchase and check for the presence of tear-off coupons for warranty repairs.

12.6. If there is no store stamp in the warranty coupons with the date of sale of the device, the warranty period is calculated from the date of its release by the manufacturer.

12.7. When repairing the device, the warranty card and the back to it are filled in by an employee of the gas industry or an organization licensed for this type of activity. The warranty card is withdrawn by an employee of a gas facility or an organization licensed for this type of activity. The back of the warranty card remains in the user manual.

12.8. The manufacturer is not responsible for the malfunction of the device and does not guarantee its operation if it provides evidence of the following to the consumer's claim:

a) non-observance of the rules of installation and operation;

b) non-observance of the rules of transportation and storage by the Consumer, trading and transport organizations;

Evidence can be presented both in the form of an opinion of an independent Expert, and in the form of an act drawn up by a representative of the Manufacturer and signed by the Consumer.



The BaltGaz company produces: Neva and Neva Lux gas water heaters, shut-off and control valves, chimneys and all the accessories necessary for connection. Water heaters operate in a flow-through mode, designed for the simultaneous connection of 1-3 water points. Due to their compact size, they can be easily installed even in small rooms used as a boiler room.

The structure and principle of operation of the speakers Neva and NevaLux

The BaltGaz line includes several flow-through gas boilers, which differ in the principle of operation and features of the internal structure. All manufactured equipment can be divided into several groups:
  • Ignition type - there are semi-automatic and automatic models. The first (4011, 5111), during operation, use a constantly burning wick, ignited by a piezoelectric element. The second, with automatic ignition, operate on batteries. The gas is ignited by a spark supplied to the burner.
  • Using modulation- gas flowing water heaters Neva and Neva Lux operate using hydraulic (5111, 5611) and electronic (6011.6014) changes in the power of water heating. There are models without automatic adjustment of the combustion intensity.
The device of geysers Neva and NevaLux is constantly being modified and modified. New models are being produced, in the design of which adjustments are made taking into account the wishes of consumers.

The technical characteristics of water heaters manufactured by Baltgaz are described in detail in the following table:

Technical characteristics of BaltGas instantaneous gas water heaters

Power, kWt)

Heating capacity (kW)

Efficiency, not less (%)

Burner modulation

continuous hydraulic

continuous hydraulic

continuous electronic

piezoelectric

electronic

natural / liquefied

natural / liquefied

Gas pressure (nat. / Liquefied) (kPa)

Gas consumption (natural / liquefied) (m³ / h / kg / h)

Chimney diameter (mm)

Required vacuum in the chimney, not less (Pa)

Max. pressure water (kPa)

Min. water flow (l / min)

Min. pressure water (kPa)

Water consumption when heating at ∆t = 25 ℃ (l / min)

Number of tapping points

Dimensions (mm)

Net weight

Body color

white, silver

white, silver

white, silver




How to install the Neva column

When connecting a Neva gas water heater, it is required to follow the manufacturer's recommendations detailed in the operating instructions. Errors during installation will result in a denial of warranty service.

Installation of the Neva column is carried out exclusively by qualified personnel (representatives of the service center or gas service) who have permission to perform work and the corresponding license.

When connecting a speaker, several basic recommendations are followed:

The service life of the Neva gas flow boiler largely depends on compliance with the rules for installation and operation, as well as regular maintenance. The period of use of the water heater is from 8-12 years.

How to turn on the Neva column

Automatic water heaters turn on independently. When the water supply tap is opened, the ignition unit gives a signal to produce a spark. The gas supplied to the burner ignites. After closing the water tap, the column turns off.

Semi-automatic flow-through boilers are distinguished by the fact that an ignition burner is used for ignition. To bring the column into working condition, you need to ignite the wick. For this purpose, a piezoelectric element is provided in the internal device. After ignition of the pilot burner, the water heater continues to operate in automatic mode.

You can adjust the Neva column using water flow and gas pressure regulators. If a modulation burner is provided in the device, the consumer sets the heating temperature, after which the electronics changes the combustion intensity depending on the pressure in the pipeline and other operating parameters.

Columns Neva - malfunctions and their elimination

The water heaters of the Russian company BaltGaz generally operate without interruptions. In automatic speakers, you have to change the batteries every six months. Every 4-5 years, the membrane (rubber gasket) of the water unit fails. To repair the water unit, use a repair kit for the column, costing 80-200 rubles.

Below are two tables. The first describes common error codes, their decoding and troubleshooting methods. The second table shows breakdowns and repair methods, without reference to digital signals.

Error code

Decryption

Cause of failures

Remedies

There is no spark. Temperature indicator is off.

Low pressure in the supply line.

Forcibly increase the water flow rate by connecting a booster pump.

The batteries are dead or inserted incorrectly.

Replace items. Check the correct position of the batteries.

The contacts are oxidized, the electronic board is damaged.

Contacts are cleaned, troublesome connections are checked. *

The water pressure sensor is broken.

Change the sensor. *

The gasket in the water unit is damaged.

Perform frog maintenance, replace the gasket. *

The control unit is out of order.

Module replacement required. *

Carbon deposits inhibit spark production.

Carbon deposits are removed from the electrode, and if necessary, its location is adjusted. *

The column is disabled.

Gas is not supplied to the burner.

Contact Gorgaz.

Stop valve closed, not fully (insufficiently) open

Open the valve.

The pressure in the line is insufficient for the normal operation of the column.

Contact Gorgaz.

The supply of bottled gas has run out.

Install the filled bottle.

The contacts of the control unit, the water pressure sensor, ionization and the solenoid valve of the wick are broken.

The connection is checked, if necessary, the supply cables are replaced, the contacts are cleaned.

The ionisation sensor is far from the flame. The wick or its candle comes into contact with the parts of the burners.

Adjust the position so that the electrode is in contact with the flame, but does not touch the wick. *

The wick is clogged.

The pilot burner jets clean and remove carbon deposits. *

The solenoid valve is out of order.

The node is changed. *

The gap between the electrode and the wick has become more or less than the norm.

The gap between the electrode and the igniter is set within 4-5 mm. *

The cable is loosely on the candle. As a result of poor contact, a spark strikes the manifold of the burner device.

Ensure a snug fit of the cable. *

Carbon deposits have accumulated on the electrode.

Service. *

The electromagnetic relay is triggered prematurely, even before the signal is received from the flow sensor.

The relay is out of order.

Replacing the assembly. *

The control unit needs to be replaced.

Replacing the assembly. *

The flame sensor is triggered even before the burner is switched on.

Ignition is carried out using matches or any other extraneous source of fire.

Carry out the ignition correctly, in accordance with the instructions given in the instructions.

The electronic control unit has stopped working.

Replacement required. *

There is no signal about water heating.

Bad contact of the cable connecting the control unit with the sensors.

Check the contact, if you need to change the temperature sensor. *

The column does not light up when the startup process is repeated seven times.

Insufficient gas pressure.

Open the gas valve completely.

Contact Gorgaz, connect filled cylinders.

Rinse filters. *

The flame controller is outside the combustion zone.

Adjust location. *

The electromagnetic relay has stopped working.

Service modules. *

The stem of the water unit is seized.

Serve the frog. *

Carbon deposits have accumulated on the electrode.

Service. *

The boiler has turned off due to a signal from the draft sensor. The code is issued after 2-5 minutes after the water heater is turned off.

Poor chimney draft.

Clean the chimney. *

The draft sensor is out of order.

Check the serviceability of the supply cables, strip the contacts. *

The code flashes for a few minutes, the LO signal is output, immediately after that the water heater is turned off.

After a sevenfold repetition of the ignition process, marker E7 appears.

A short circuit occurs, turning off the water temperature sensor.

The short circuit is removed or the sensor is replaced. *

Insufficient pressure to start the main burner.

Flow rate less than 3.5 l / min.

Set the flow regulator to a higher value.

Flush the heat exchanger. *

Contact your local utility company to clean the cold water system.

The temperature at the inlet to the column and at the outlet differs slightly.

Set a higher heating temperature.

The water heater shuts down spontaneously, an L0 error appears.

Flame detector not positioned correctly.

Adjust the sensor position within 5 ± 1 mm from the top edge of the burner. *

The boiler does not heat the water up to the specified temperature.

The water flow rate is incorrectly set in relation to the gas supply.

Reduce water flow rate or increase gas flow.

Poor gas pressure.

Open the gas supply valve.

Write a statement to Gorgaz, install a filled cylinder.

Rinse or change filters. *

The heat exchanger is clogged, dust has accumulated on the radiator fins, as evidenced by a yellow flame.

Clean burner nozzles, column coil. *

Limescale has accumulated in the heat exchanger.

Flush the coil. *

The frog or the control unit does not work.

Service, change the diaphragm, clean, lubricate the stem, install a new spring. *

Ignition is carried out with a characteristic pop and flame.

The wick fire does not deflect towards the burner. Pilot jets clogged.

Clean the wick, align it correctly in relation to the burner. *

At normal pressure in the pipeline, at the outlet of the boiler, water practically does not flow.

The heat exchanger or the hot water supply line is clogged.

Rinse the radiator, remove limescale. *

The water filters are dirty.

Perform cleaning. *

The column is malfunctioning, there are strong differences in the temperature of heating hot water.

Flow rate incorrectly adjusted.

Increase the duct.

The water pressure in the pipeline is less than 30 kPa.

Contact utilities.

The water heater is connected to the water supply system with violations.

Fix violations. *

After closing the DHW tap, the burner flame does not go out.

The frog stem is stuck.

Disconnect the gas supply. Call emergency services.


* - The work is carried out by representatives of the service center or the Gas Service.


The following table lists common breakdowns, without reference to codes:

What caused

The wick does not light up the first time, or does not work at all.

Valve closed.

Open the valve.

Pilot burner jet clogged.

Clean the jets. *

The gas in the cylinder has run out.

Install a full bottle.

Breakdowns in the supply cable between the piezoelectric element and the torch.

Eliminate open contact in the supply cable. *

The piezo ignition system does not work.

The candle is out of order.

Replace node. *

When the gas valve is released to the wick, the flame is extinguished.

Violation of the electrical circuit connecting the thermocouple - relay - solenoid valve.

Check the integrity of the cables, tighten the contacts. *

In this case, the strength of the connection should not exceed 1.5 N / m (0.15 kg / m).

Higher voltage will damage the module.

The electrical circuit of the water-gas unit and its elements do not work.

Replace hardware. *

The burner does not fire or does not start the first time.

Incorrectly set gas supply.

Set the regulator to maximum.

Insufficient gas pressure.

Application to Gorgaz.

Insufficient pipeline pressure.

Install a booster pump, contact the public utility.

The "frog" does not work: the filters are clogged, the membrane has broken.

Replace the gasket, rinse the filters. *

The boiler turns on with a clap.

Burner nozzles clogged, wick not positioned correctly.

Service the wick. *

Gas glows yellow.

Dust has accumulated on the main burner.

Perform maintenance. *

The column turns off spontaneously after 2-3 minutes of operation.

Poor traction (the controller gives a shutdown signal).

Clean the chimney. Check the tightness of the chimney joints. *

The water assembly gasket is callous or ruptured.

Service and replacement of components is required.

The difference in water pressure at the supply and return of the water supply system before and after passing the column radiator.

Limescale has accumulated inside the coil.

Flush radiator. *

Water filters clogged.

Weak heating.

Incorrectly set gas and water supply settings.

Set the heating temperature by changing the intensity of the gas supply to the burner

Dust has accumulated on the burner, column radiator.

Clean the burner device, remove soot from the radiator. Rinse the pipes from scale. *

The water and gas unit does not work.

Replace module. *

Insufficient gas pressure.

Contact the appropriate service.

The water heater makes a lot of noise during operation.

Excessive water flow.

Reduce water flow rate.

Misaligned or worn gaskets.

Replace sealing gum. *

The flame does not extinguish when the tap is closed.

The water regulator is out of order.

Repair of the frog water unit is required. Eliminate stem jamming, change the spring.


* - DIY repair is prohibited, the presence of a specialist is required.

How to clean the Neva column at home

In order for the Neva boiler to continue working properly, every 2-3 years it is required to flush the heat exchanger, removing the accumulated scale and soot. It will be possible to clean the Neva gas water heater at home even with poor water quality. Maintenance is carried out in several stages:
  • Remove the radiator- to pull out the heat exchanger of the Neva column, unscrew the casing, disconnect the water and gas. Dismantle the smoke exhaust unit. Take out the radiator.
  • Flush and clean the heat exchanger- soot is removed from the plates using a stiff brush and soap solution. To remove scale, the internal cavity of the coil is washed with special "chemistry" or citric acid.
In case of serious contamination, the column is serviced at a specialized service center. Flushing is carried out using pumping equipment.

A gas water heater is a water heater that has excellent technical characteristics. Household appliances of this type have become more in demand recently, however, in order to purchase and install a structure with your own hands, you will need to figure out how the device works and what advantages and disadvantages it has. The peculiarity of such columns is that they are needed in those houses and apartments where there is no hot water supply or where it is often turned off.

Feature: Neva 4511

The geyser device is a device for heating water, and gas is required for its operation. The main criterion for choosing such installations is, of course, the characteristics of the product, as well as its cost and quality.

If you choose these installations for technical characteristics, then you need to pay attention to such points as:

  • Ignition type;
  • Chimney type;
  • Power;
  • Safety;
  • Dimensions;
  • Additional functionality.

If we consider the quality of products, then it is worth considering the entire model range and it will be possible to find out that a huge number of such structures are on sale. The most popular and best model is the Neva 4511, which has an unrealistic number of positive reviews, and also has all the quality certificates and compliance with the GOST standard.

Column Neva and its ignition

As already mentioned, there are an incredible number of models of geysers, and these can be: 3208, 4510, 4513, 3212, 5513, 3010 and not only. The principle of operation and the connection diagram are almost the same. It is worth noting that the process of operating a product called Neva requires lighting the column, which means igniting the gas.

There is equipment that differs according to this criterion, and there are products with:

  • Manual ignition;
  • Piezo ignition;
  • Electronic ignition;
  • Microturbine ignition.

If the column is ignited manually, then this is an old model, since modern speakers are automatic devices or Lux transit, which is not difficult to cope with. The type of piezo ignition is similar to piezo electric stoves, in which to turn on the unit and ignite the gas, just press 1 button. This option can be found in modern devices, since it is very convenient and most importantly safe to use products in residential premises. Electronic products are considered the most in demand, but more expensive, but this does not affect their demand in any way.


They have such qualities as:

  • Reliability;
  • Profitability;
  • Ease of use.

The spark is generated in the same way as in cars, by means of a small battery, however, batteries are most often used.

Column Neva 4511 is a model in which just such a ignition is installed.

There are also microturbine types of ignition, in which current is generated by a hydrodynamic generator, which is controlled by a water flow. In terms of cost, they surpass all previous models, including the HSV, Nomi, but they are the safest and provide good service.

Operating instructions for the gas water heater Neva 4511

Studying such a document as the operating instructions is the best opportunity to learn what actions are needed to avoid problems in the operation of the device, as well as not to harm yourself and the equipment. In other words, you need to familiarize yourself with the rules for safe operation. First of all, it is important to remember that gas water heaters are equipment of increased danger and the likelihood of an accident is very high, which can harm the sensors, in particular, the ionization sensor and human health. This element is responsible for shutting off the gas supply if the burner goes out.

In addition, each element that makes up the gas water heater must be in good working order.:

  1. The temperature sensors must be in good working order, since they are triggered at the moment when the ionization sensor stops functioning.
  2. Thanks to the heating sensor, you can monitor the temperature in the flow heater, as well as regulate the temperature of all equipment.
  3. A water pressure sensor is required for the main task of the device, in particular for turning on and off the gas supply if there is an automatic water intake.
  4. It is imperative to monitor the health of the sensor that controls the temperature difference in order to stop the burner operation in time and avoid the boiler explosion.

It is strictly forbidden to use a column without a gas and water pressure sensor. It is with its help that you can control the flow of water and gas into the column cavity. If the tap with water is open and it is turned off, then the gas will not be supplied automatically, which is facilitated by the safety valve.

Description of the geyser Neva

Why do so many make decisions such as purchasing equipment such as a gas water heater? Regardless of whether the installation is old or new, it must be of high quality, wear-resistant and correctly installed. In addition, you need to pay attention to how powerful the structure has and how quickly it can heat water to heat the room. Naturally, if the house or apartment is large, then you need a device that will be able to heat it.

Columns of gas type are divided by power:

  • 17-20 kW (small speakers);
  • 20-26 kW (mid-range speakers);
  • 26-28 kW (large speakers).

As for the Neva column, in particular the 4511 model, it has a power consumption of 21 kW, however, it is capable of producing up to 11 liters per minute. To approximately determine liters per minute, it is enough to pay attention to the instruction manual. It is worth noting that the Neva 4511 model is perfect for two tapping points, and if you need to connect to a larger number of points, then an installation with a higher power is required.

Specifications: gas water heater Neva 3208

The service life of such a structure as Neva Lux is long enough, however, in order for it to serve properly, and no repairs are required, since malfunctions will appear, it is necessary for the owner to know how to use the product.

Typically, this equipment does not require:

  • Traction adjustment;
  • Elimination of fistulas, due to which the tank flows;
  • Clean the radiator.

It is worth noting that the heater will not work if there is low pressure water in the pipes, and it is completely difficult to find a gas source from which the device operates, and therefore these moments can be called negative aspects of the structure.


A column called Neva 4511 can function even if the pressure is 0.2 atmospheres, but it is not advisable to use it for a long time.

If such an electric gas water heater does not work well, then the heat exchanger may need to be replaced. The heater has the peculiarity that you do not need to contact the service center to change this part.

How does a gas water heater work

The task of this type of water heater is to respond quickly to the opening of the hot water tap, as a result of which the burner turns on. For a detailed description of the principle of operation of such a device, it is enough to pay attention to the sequence of actions.


Namely:

  1. Initially, it is required to ignite the igniter, which is located in the cavity of the viewing window directed towards the burner.
  2. After the tap is open, water begins to flow in the DHW system, which increases the pressure in the pipes.
  3. Thanks to the water unit, the membrane is triggered and the stem moves, which is connected to the valve installed on the gas pipe.
  4. Since the membrane of the water unit presses on the valve, it opens and the supply of fuel to the main burner begins, which is ignited automatically from the igniter or from the electrode, depending on the design model.
  5. It is possible to adjust the flame manually by means of a special tap, which is displayed on the front panel.
  6. Water enters the cavity of the heat exchanger in the gas column, after which heating begins in the coil, which goes around the copper casing.

It is not too difficult to turn on the device, and if adjustment is required, then it is enough just to use the instruction manual. As soon as the water has entered the consumer and the tap is closed, after the membrane tap is closed, the stem is pulled back on the frog, the gas supply valve is closed, and the burner goes out.

Repair of the gas column Neva

Experts do not recommend that you carry out maintenance yourself, especially if you need to not only configure the equipment, but also disassemble it. Flowing gas water heaters are needed so that the water does not stagnate, but flows, and the fact that it flows would be enough for consumer needs.

In this device, the solenoid valve fails quite often.

When you open the tap, you can hear the machine click, which contributes to the ignition of the burner, but no gas is supplied. It is through the solenoid valve that gas is supplied to the burner. Replacing it is not difficult, just like the heat exchangers. The diameter of the valve is standard, and the connection is not difficult. To purchase a spare part, you just need to know the model of your gas water heater or take an old faulty valve with you.


To remove and install equipment for heating water, it is best to contact specialists with extensive experience, who can not only carry out all the necessary actions, but also provide a guarantee.

For the installation of a gas water heater, a special permit is required, since it is necessary to supply power from a gas pipe, and this is possible only with special equipment. After that, you need to register the gas water heater as an object of gas consumption, especially if it is connected to the central highway.

With regard to operation, it is advisable not to heat it to the maximum level, since this will only accelerate the process of salt and scale formation on the cavity of the heating element. It is important to take into account the hardness of the water used and select a special agent that can soften it, which will significantly extend the service life of all equipment.

Centralized hot water supply is, of course, a convenient thing. But often, moving into an apartment rented or purchased on the secondary housing market, we come across an outlandish unit - an old gas water heater. How is it safe to use it?

A gas water heater or, as it is officially called, a flowing gas water heater, appeared in our country with the beginning of mass housing construction in the 50s of the twentieth century. It was the installation of gas water heaters in apartments that made it possible to quickly solve the problem with hot water supply without building expensive heating plants and pipelines.

How to determine the type of gas water heater?

First of all, let's define the terminology - we will call the old one a gas water heater, the design of which provides for a constantly burning ignition wick. The wick is ignited with a match or, in more modern models, with a spark from a hand-held piezoelectric igniter.

The overwhelming majority of gas water heaters installed in "stalinkas" and "Khrushchevs" belong to two varieties - KGI-56 and similar in design L-1, L-2, L-3, GVA-1, GVA-3, early VPG models. It is easy to distinguish them from each other by the control knobs.

Column KGI-56 (gas column of the Iskra plant, construction in 1956) was widely used in the construction of multi-storey buildings in the 50-60s of the last century. It has a rectangular, slightly rounded body with an oval opening for ignition and two levers in the lower part of the body - a lever for starting the ignition burner and a lever for controlling the power of the main burner. In later versions, the front panel also has a gas solenoid valve button.

Columns of the L series (Leningrad), GVA (automatic gas water heater), VPG (gas flowing water heater) are structurally similar and have one rotary knob in the center and (optionally) a button for an electromagnetic gas valve.

HPG columns became, perhaps, the most common in Russia and were produced in huge batches under various names (Neva 3208, Neva 3210, Neva 3212, Neva 3216, Darina 3010 and others).

The era of mass installation of gas water heaters in our country was short-lived - after 20-25 years, almost all new buildings were connected to hot water supply networks. Columns remained the hallmark of the "Stalin" and "Khrushchev" buildings. But their owners do not complain - this is Russia. And while the "lucky ones" with centralized hot water supply every summer for two or three weeks heat water in a basin on the stove, they calmly use hot water. And the gas water heater costs much cheaper than hot water from the pipes.

And that is why, probably, the residents of new buildings pass on horror stories to each other about an unknown and terrible apparatus - a gas water heater. And it breaks down every other day, and it takes a long time to kindle it, and it is dangerous to use it. Is it really?

Is it safe to use an old gas water heater?

A person who is accustomed to centralized hot water supply usually judges the safety of a gas water heater according to rumors and speculations of friends and acquaintances. Often these people have not even seen a gas water heater, especially of an old design. Hence, terrible legends are multiplied about almost daily explosions of gas columns. It comes to the point that some families, living in a rented apartment and having a completely serviceable apparatus, heat hot water in a basin on the stove.

All these horror stories are greatly exaggerated. Any gas water heater, even if it was made half a century ago, has safety devices in its design. Such devices include a water regulator, a flame detector and a draft sensor.

The main burner burns with a non-smoky blue or light yellow flame;

When the taps are closed at the water points or on the inlet pipe, the column goes out immediately, without delay;

The column allows you to regulate the temperature of hot water from lukewarm to scalding hot;

The column does not turn off spontaneously during use.

If any of the above is not met, then the column needs to renovate or, if the repair is not profitable, replace with a new one.

Please note that 5-10 seconds after turning on the column, very hot water can flow from the tap for several seconds, gradually changing with water at the set temperature. You can get burned out of habit, but this is not a malfunction, but a design feature.

Can I use a faulty gas water heater?

There can be only one answer to this question: absolutely not! And do not be convinced by people who successfully operate a gas water heater with minor or not very minor malfunctions.

The point is this. It is quite difficult to find an old gas water heater from the 50-70s in complete serviceability. Most often, the flame control system turns out to be out of order - even the new one was not distinguished by good reliability. Therefore, quite often the gas valves in the columns are stuck open. Even the gas workers themselves did this, since it was tight with spare parts. It is easy to determine this - the button of the gas valve is not pressed, or it is pressed very easily. With some care, such a column works without problems.

Sometimes the water regulator is faulty. The author himself used a column with this problem for several years. I had to open the water, and then light the column manually. When turning off, it was necessary to close the gas supply to the main burner and only then turn off the water. It was customary, and even then, more than once, due to forgetfulness, it turned out to boil the column.

But for a person accustomed to using centralized hot water supply, this is unacceptable! Habits developed over the years are not easy to change. You can argue on anything that on the very first day you will boil a column with a faulty water regulator. Therefore, the device must be in full working order.

2016-10-29 Evgeny Fomenko

How to ignite an electronic ignition device

Before turning on the column, it is necessary to ensure that there is an inflow of fresh air in the room, since oxygen is burned during operation. All Neva devices are manufactured regulated for a certain type and pressure of gas - natural G20, liquefied G30 with the corresponding pressure of 1.3 kPa and 2.9 kPa.

For example, consider how to light a Neva 4511 and Lux ​​5611 gas column with electronic ignition from 1.5V LR20 batteries (see also the article on why the Neva column does not light up). These devices have continuous hydraulic flame modulation. The front panel is equipped with a viewing window, gas and water adjustment knobs, and a digital display.

To turn on, install the batteries in the battery compartment, first make sure that the contacts of the batteries and the battery compartment are not oxidized.

Open the shut-off valves upstream of the device. Then turn the tumblers to the minimum position. If the ignition occurs for the first time, or after a long period of inactivity of the device, it is necessary to remove air from the system. To do this, it is required to open and close the valve with water several times to continue ignition, since spark discharges last about seven seconds. After switching on, being careful not to get close to the viewing window, you need to make sure that the flame burns even, blue, without the yellow edges that appear if the burner is clogged.

The jet is adjusted with a handle, if the water supply system has a low pressure, it should be set to the minimum position, while at the outlet of the device you will receive a small, medium amount of water. If the pressure inside the line is high and you need a lot of water, the regulator should be set to the maximum value. If, at a low head, you set the maximum value, then the column will go out, it can also go out if the valve is opened for a small flow. In order for it to light up again, you need to turn the regulator to the minimum position or increase the pressure of the jet.

You can adjust the temperature with the gas control knob - the maximum position increases its flow rate and temperature of the outlet stream, the minimum - vice versa. In addition, the temperature of the outgoing jet can be adjusted by changing its flow rate with a hot water valve - opening it more strongly, the temperature will decrease, screwing it on, it will increase.

But it should be remembered that the resulting temperature is limited by the power of the device, with a high flow rate, especially in winter, it may have an insufficient temperature.

When the jet control toggle switch is set to the minimum position, and the gas regulator to the maximum position, the heat exchanger will overheat, the column will go out, as the overheating sensor is triggered. To turn on the device again, you need to close the hot water tap, then open it again. Reduce gas consumption or increase water consumption using toggle switches. Overheating of the heat exchanger leads to the formation of scale, noise during operation. This reduces the productivity of the device, reduces the outflow flow; therefore, it is not recommended to dilute the hot stream with a cold one, as the service life of the device decreases. From user experience, the temperature should not be set higher than 60 degrees.

To turn off the unit, it is enough to close the tap, make sure that the main burner has gone out. If it turns off for a long time, close the shut-off gas, water valve.

How to light a piezo column

Models of water heaters Neva 3208, 3212,4011 differ from models 4511,5611 in the type of ignition with the help of a piezoelectric element.

To turn on the Neva 4011, you need to open the gas, water shut-off taps, which are located in front of the device. Set the gas regulator knob (on the front panel) to the “Ignition” position, drown it to the limit. While holding it with one hand, press the piezo ignition button with the other hand, which is located at the bottom of the device. In this case, a spark discharge should appear between the ignition plug and the ignition burner, which ignites the gas supplied to it.

The holding time is about 20 seconds, until the ignition burner ignites. Then the handle can be lowered. At initial start-up, bleed air from the gas system. To do this, while holding the toggle switch, press several times, release the piezo ignition button.

Next, you need to put the regulator in the mode "Turning on the main burner". In this case, only the pilot burner burns, the main burner ignites after opening the hot water valve. If the tap is open, and the main one does not light up, it is necessary to adjust the pressure with water regulation, or open it more strongly. You can turn off the column by turning off the water.

The inclusion of columns 3212, 3208 also begins by opening the shut-off valves. Next, fix the "Ignition" toggle switch opposite the risks, press the button of the solenoid valve. While holding the button (for about 60 seconds), press the electric ignition button several times (or light it with a match if there is no button, as is the case with some 3208 models) until a flame appears on the ignition burner.

After releasing the solenoid valve button, move the toggle switch all the way to the right, to the “Big flame” position, the pilot burner is working, the main burner has not yet been ignited. When you open the tap, the main one lights up. To turn off the device, you need to close the tap, turn the handle on the front panel counterclockwise until it stops, close the valves of the gas pipeline, water supply.

Video on igniting the gas column Neva 3208: