Repair Design Furniture

Volumetric airflow

The HG-S series are models that have, perhaps, the best price-quality ratio on the market. They have a stylish, modern design with a molded front panel. Thanks to the special aerodynamic shape of the fan and outlet louvers, a powerful air flow and its uniform distribution throughout the room, as well as a low noise level, are ensured.

Outdoor unit SRC20HG-S
Indoor unit SRK20HG-S
Refrigerant R410A
Operating mode cold/heat
Energy Efficiency Rating A
Cooling capacity, kW 2.07
Heating capacity, kW 2.22
noise level, dB(A) 27
Power supply, V/f/Hz 220-240/1/50
Rated consumed cooling current, A 3.21
Rated consumed heating current, A 3
Consumed cooling power, kW 0.64
Heating power consumption, kW 0.61
EER (energy efficiency ratio) cooling 3.23
EER (energy efficiency ratio) heating 3.64
The size of the internal block, mm 268x790x199
External block size, mm 540x780x290
Weight of the indoor unit, kg 8.5
Mass of the external block, kg 29
Height difference, m 10
Operating range ext. cooling temperature, C -30 ~ 43
Operating range ext. temperatures during heating, С -5 ~ 21
Fresh air supply -
The presence of an inverter -
Piping size, mm 6.35/9.52
Maximum pipeline length, m 15
Compact size, "flat" design with shallow indoor unit depth.
The built-in auto-restart module allows, after a power failure, to resume operation with the parameters that were set at the time of the shutdown.
Washable Titanium Oxide Photocatalytic Deodorizing Filter - To restore the deodorizing function, wash the filter with water and dry in the sun.
The filter on natural enzymes - destroys bacteria, fungi and viruses.
Self-cleaning mode.
Tourmaline coating - air ionization 24 hours a day.
Illumination of remote control buttons.
Energy class "A".
Operation for cooling down to -30°С (subject to the installation of a winter kit).

Automatic operation

This mode automatically selects between heating, cooling and drying.

Intensive mode (Hi power)

This mode is useful if you want to quickly reach the desired temperature. The air conditioner can operate in intensive mode without interruption for 15 minutes.

Three "hot" modes

Three “hot” modes are available in this series of air conditioners. "Hot start" allows you to start working immediately, and "hot spurt" speeds up heating, raising the set temperature by another 2 degrees. The third “hot” mode is heat recovery (HOT KEEP). It is used for automatic defrosting or to prevent cold air from entering the system. These three hot control systems provide more comfortable and efficient heating.

Automatic damper control

In any mode of operation, the optimal angle of the damper is selected. COOLING, DRYING - Horizontal blowing, HEATING - Inclined blowing.

Position memorization

The swing flap can be stopped at any angle. After switching on again, the damper returns to the saved position.

Vertical swing damper

When swinging, the damper can be adjusted to any angle from 0° to 90°. FLAPPER SWING - The vane swings up and down.

On Timer mode (timer operation)

Intelligent functions allow you to turn on the air conditioner some time before the set one, so that at the set time the temperature has already reached the desired value. This mode is activated by the ON TIMER button (only for cooling and heating modes).

Programmable 24 hour timer

By setting the air conditioner on and off timer, you can set two timer operations per day. Once set, the timers will turn the system on and off at the correct time each day.

Sleep mode

Mode for increasing comfort during sleep.
When working for cooling, during the first hour after switching on the mode, the temperature drops by one degree relative to the set one, during the next hour the temperature is maintained equal to the set one, and during the subsequent time the temperature increases by one degree relative to the set one.
When working for heating, the temperature drops every half hour by one degree relative to the set one (during the first hour), then by another one degree during the second hour.

Drying

Dry mode allows you to reduce the humidity in the room without changing the temperature in it.

Off Timer mode (operation without timer)

Allows you to set the time to turn off the air conditioner within a 24-hour period in 10-minute increments.

Economy mode

In this mode, the intensity of cooling or heating decreases due to, respectively, an increase or decrease in the set temperature according to a certain algorithm.

Ionization 24 hours a day

Tourmaline plate generates negative ions 24 hours a day. Even when the air conditioner is turned off, the ion concentration is maintained at the same level as in the forest or near the river.

Button illumination

With the help of an infrared remote control, the buttons of which glow in the dark, you can conveniently control all the functions of the air conditioner.

Backup switch

The main unit has a back-up switch. It can be used to turn the air conditioner on and off if the remote control cannot be used for any reason.

Auto power on

If there is an unexpected power failure of the air conditioner, the automatic restart function saves the operation settings that were in effect immediately before the power was turned off, and after the power is restored, the system will automatically resume operation with the saved settings.

Defrost controlled by a microcontroller

This mode automatically removes frost from the air conditioner. It allows you to avoid unnecessary operation of the air conditioner in other modes.

Removable room air intake panel

If necessary, clean the filter. The internal air intake panel is easy to open and close. The panel covering the intake air hole is also removable.

Self-diagnosis function

In the event of a malfunction of the air conditioner, the microcontroller that controls it automatically starts the self-diagnosis function. (The air conditioner should be inspected and repaired by authorized dealers.)

Washable photocatalytic filter

Effective air deodorization. Reusable filter: to restore the functions, it is enough to wash the filter with water and dry it in the sun.

Enzyme filter

Effective destruction of mold spores and pathogenic bacteria.

SRK-HG-S air conditioners cool the room in minutes.

Climatic units of this series are equipped with the HI POWER option, which allows you to reach the required temperature in a short time. This option is enabled with just one key on the remote control.

AIR CLEANING SYSTEM

In the room where the SRK-HG-S air conditioner operates, the air will be fresh, without unpleasant odors.

IONIZE THE AIR. With the help of an innovative tourmaline coating, which is applied to the heat exchanger and other parts of the indoor unit, the air in the room becomes fresh, a person feels better, and his mood improves.

CLEAR THE AIR FROM VIRUSES AND BACTERIA . Thanks to the self-cleaning mode, after each shutdown, the air conditioner automatically dries from the inside and treats the mechanism with an antiseptic, which allows it to effectively fight bacteria and mold.

DESTROY UNPLEASANT ODOURS. A special reusable filter relieves the room of unpleasant odors, including tobacco smoke.

COOL WITHOUT DRAFT

By controlling the air flow of the SRK-HG-S split systems, you can create various air conditioning scenarios.

In this series of air conditioners, comfortable air conditioning is ensured by manual or automatic selection of the direction of the air flow (from below, from above, and also in both directions). In order to avoid drafts and colds, it is recommended to supply cool air only upwards in the room, and warm air downwards.

IDEAL FOR INSTALLATION IN SERVER ROOMS

SRK-HG-S air conditioners can be upgraded with a winter kit for cooling operation down to -30˚С.

Under the condition of this refinement, the air conditioning units of this series can be effectively used in server rooms, as well as other special-purpose rooms that require year-round maintenance of low temperatures. After retrofitting, SRK-HG-S air conditioners can provide cold at outdoor temperatures down to -30˚C.

Mitsubishi Heavy SRK20HG-S/SRC20HG-S is a stylish and versatile air conditioner model that does an excellent job of cleaning, cooling and heating air in very small rooms with an area of ​​​​only 20 sq.m. The ideal solution for installation in small offices and small living rooms.

A huge number of practical and useful modes of operation are ideally combined with the cost of the device and its cheap maintenance, which does not require the intervention of service departments for regular cleaning.

Fine cleaning

Here, the manufacturer provides for the finest cleaning of the injected air, which is passed through a special filter design with natural enzymes. All sources of natural and artificial pollution are either delayed or completely neutralized.

You are completely safe from harmful microorganisms and are completely protected not only from the usual urban pollution or allergens characteristic of suburban life. No known viruses or bacteria will be able to freely enter your premises through its cleaning system.

The second line of defense is the photocatalytic filter - additional protection in combination with the air deodorization function. Serves as an active barrier to unpleasant odors and destroys their sources.

All internal elements of the outdoor and indoor units are coated with a special composition with antibacterial properties. Actively protect parts of the structure from the possibility of mold formation.

Ionization - constantly

Air ionization is carried out even when the air conditioner is turned off. The special tourmaline coating of some parts of the indoor unit effectively interacts with oxygen and forms an additional amount of ions that refresh the air.

Their concentration per unit volume is comparable to the level next to a small waterfall in a dense forest. When switched on, the ionization efficiency is greatly improved.

Volumetric airflow

Not every developer of air conditioners can boast of a 3D effect of air flow distribution. The air entering the room through a specially tuned system of placing constantly moving blinds by three electric motors at once creates optimal air mass flows, eliminating the appearance of turbulence and the formation of drafts. Volumetric airflow is activated by pressing one button on the remote control.

Manual regulation

In addition to the automatic settings of operating parameters, you can manually set the parameters you like the most and remember them for repetition the next time you turn them on without your intervention.