Repairs Design Furniture

Diesel generator installation hell. DESEL power plants DES (Hell) DSU. How to choose a diesel power station

"Diesel generator installation AD-10S-T400 * DAY DSU based on the TSS Diesel engine is designed to generate electricity as the main source ..."

Diesel generator

AD- 10S- T400 *

This DGU based on the TSS Diesel engine is designed for

electricity generation as the main source

power supply (in remote settlements, on construction

venues, in watch settlements, on drilling rigs, etc.) and

as a backup power supply, where

increased power supply reliability (in power systems

enterprises, educational institutions, medicine, in providing

functioning of banks, hotels, shopping, warehouse complexes, etc.).

All components pass input quality control, then provides complete control of production process and finite quality control of products in accordance with the international ISO quality system, as well as with EPA, CE and other national standards, naturally, and Russian.

All DGU is fully prepared for operation, equipped with a silencer, acb, flooded with oil and coolant and 2-hour running.

Basic information:

Rated power, kW / kVA, 10/13 Maximum power, kW / kVA, 11/14 Rated current, A 19 Ring current variable three-phase rated voltage, in 230/400 Nominal frequency, Hz 50 Power factor (COS F) 0.8 Engine shaft rotation frequency, rpm 1500 Fuel consumption, (g / kW * h) / (kg / hour) / (l / h) 265/186 / 2.2 Capacity of fuel tank, l 45 Climatic equipment UHL / NF / 1 Maintenance every 250 hours or every 6 months warranty period of 12 months or 1000 hours depending on what will come before.



Main dimensions:

Execution: D X W x in (cm) Mass (kg) Open 430 115x60x110 in Casing 580 175x85x104 under the hood 180x100x140 563 on the chassis 330x170x220 763 container

- & nbsp- & nbsp-

1. TSS Diesel

2. TSS SA

3. Base frame with anti-vibration mount

4. Fuel tank, l 45

5. Fuel filter (long / diameter, mm) flowing (61/55)

6.To fuel show meter

7. Lubrication system with liquid-oil heat exchanger

8. Macked filter (long / diameter, mm) flowing (92/86)

9. Oil pump gear

10. Water radiator Block with fan

11. Mehanic fan impeller with protection

12. Filter (Diameter Extra / Internal, mm) 195/125 2 pieces, 60, 550

13. Accumulatory battery, and · h, and

14. Easitive pipe

15. Flexible compensator

16. noise blower, noise level 60 dB

17.terests of the exhaust manifold

18. Microprocessor Electric Aircraft Management System

19. Treatment of insulation control to work in networks with "isolated"

neutral

20.Tellium high pressure pump

21.Complek documentation in Russian

Additional equipment:

Preparation electrical heater of coolant from the network 220 V.

Preparation electrical heater of oil from the network 220 V

Preparation diesel coolant heater PZD,

Noise protective casing

Outdoor fuel tank

Execution on a single or two-axis trailer or on the car chassis,

Execution in a warmed "North" block container, with a configuration configuration equipment and systems needed to ensure the safety, work and maintenance of DGU (equipment and execution of the block container is appropriate),

Remote monitoring and management of DSU:

With cable connections (up to 300 m distance),

Through radio communication (up to 3000 m distance)

Via mobile communications (GSM channel),

Via the Internet (TSP-IP protocol)

DSU designation:

Engine Features:

The TSS Diesel engine, compared with the analogs, has a wide range of applications, low fuel consumption, low noise level, low emissions, high reliability and long service life: more than 8000 hours before overhaul. Diesel engines satisfy the ever-changing environmental requirements, and correspond to the Euro standard.

Benefits

1. Using an improved turbocharger improves performance, reduces fuel consumption and operating costs.

2. The use of high-end fuel system of leading manufacturers, improved system functioning and lowered the temperature threshold of the cold engine.

3. The nozzles has several channels of different diameters, and in connection with the quality of spraying and engine efficiency improves.

4. The crankshaft is made of high carbon steel. It has a continuous molecular structure, as a result, a high threshold of metal fatigue, bending resistance and stretching. The surface of the shaft is nitrates due to which the wear resistance increases, eliminating the possibility of defects in normal operation.

5. The sleeves are made of wear-resistant and corrosion-resistant materials. Have good deformation resistance. Forced cooling and an improved lubricant system contribute to the prevention of corrosion at low temperatures.

6. A specially designed combined muffler significantly reduces the noise level.

7. Fight frame design with shock absorbers based on elastic materials extinguits vibration to minimum indicators.

- & nbsp- & nbsp-

Warning signals

High Engine Temperature - High Battery Voltage

Temperature Sensor is defective - Warning for additional inputs

Low oil pressure - battery charging failure (generator)

No revaluation number - Shared emergency stop (blocks

Excess generator frequency re-launch)

Refusal to stop the engine emergency stop signals

High engine temperature - generator frequency drop

Low oil pressure - generator voltage

Excess rotation speed - generator voltage drop

Rotation speed drop - launch failure

The engine came out of control - refusal of additional entrances

Exceeding the generator frequency depending on the specific purpose and operating conditions, our stations can be automated and executed upon request of the Customer.

The degree of automation:

The first degree of automation

The next minimum operations are performed:

automatic adjustment of the rotational speed of the diecel shaft, voltage and temperature in cooling and lubrication systems;

local and (or) remote control of the start, stop, prediction and post-bed operations;

automatic recharging of the AKB, providing start and nutrition of automation tools;

automatic emergency warning alarm and protection;

Indication of values \u200b\u200bof controlled parameters on the local shield and (or) remote remote control.

Second degree of automation

In addition, the 1st degree of automation is performed:

remote automated and (or) automatic control of start, stop, prediction and post-bench operations;

automatic reception of the load during autonomous work or the issuance of the readiness of the readiness to receive the load;

automatic maintenance of the engine in readiness to the rapid reception;

automated emergency start and / or stop;

Executive alarm.

The third degree of automation

Additionally, the 2nd degree of automation must be performed:

Automatic replenishment of consumable tanks: fuel, cooling oil;

Automated and / or automatic control of auxiliary units and (or) individual engine maintenance operations.

Execution options:

Open Type:

The easiest and most economical version of the DSU. It can be installed on construction sites, in the watches, on drilling plants, etc.

Hood:

Weather-protective hood is a convenient and universal solution for the frequent use of the power plant in various conditions.

Power plants in the hood can be mounted on an open area, car chassis, or trailer without additional refinement. It is possible to work on a flat platform without special installation.

- & nbsp- & nbsp-

Technical documentation in Russian:

Technical certificate

Operating and Installation Instructions 10 years Estimated service life block container

Completion of the system of life support block container:

Air valve, pcs 2

Unregulated metal louvre lattice, pcs 2

Gas fleece pipeline to diesel and silencer

Electrical wiring through a distribution panel with automata triggering with current strength, and 32

Working lighting, LED tape, by moisture-proof of the entire length of the container

Electrical outlets with grounding on the side walls, 1 piece on each

Auto Fire Sound and Light Detector

Automatic fire extinguishing system collected on powder fire extinguishing modules designed to extend foci of fires of class A, B, C and hardware (class E)

Trailer:

Mon-axis trailer with brake mass of transported cargo, no more, kg 800

- & nbsp- & nbsp-

C-RU. 75.B.18854:

Diesel electrical units and power plants of trademarks "TSS", "Slavyanka", "Lester", "Mitsudiesel", "TSS"

stationary, mobile, in containerization with a capacity of 10 to 5000 kW meets the requirements of regulatory documents:

GOST R 53174-2008, GOST R 51318.12-99 (CESPR 12-97), GOST 12. 1.012-2004, GOST 12.1.003-83.

Serial edition.

Similar works:

"UDC 004.932.72" 1 Normanova Svetlana Vladimirovna recognition of buildings on satellite images of ultra-high resolution with the help of neural networks 05.13.23 - Systems and means of artificial intelligence thesis for the degree of candidate of technical sciences Scientific director Doctor of Technical Sciences, pro ... "

"BOOX C67ML Magellan 2 User Guide Contents Precautions 3 Specifications 4 Appearance and Controls 5 Getting Started 6 Main Menu 8 Settings 11 Working with Keyboard 17 Working with Applications 18 File Manager 24 Installation and Delete ...»

The main technical characteristics of the 320 kW diesel power plant on the basis of the engine YAMZ-8503.10:
Name of the measurement unit value
Cooling type radiator
Rated power (long) kW / kVA 320/400
Maximum hour Power kW / kVA 352/440
Current Code variable three-phase
Rated voltage in 400
Nominal frequency Hz 50
Nominal power factor 0.8
Rated current A 576
Engine Rotation Rotation Frequency Min-1 1500
Filling tanks l:
Fuel system 800.
Cooling system 150.
Lubrication system 65.
Fuel consumption at 100% load l / h 78
Specific oil consumption% of fuel consumption 0.3
Minimum launch temperature without heating 0С -10
Overall dimensions mm Length x Width x Height 3335 x 1330 x 1920
Mass of dry electrical unit kg 4600
Resource to major repairs M.ch. 15000.
Primary engine YAMZ-8503.10
Generator Synchronous Pro28L G / 4 "Linz Electric" (Italy)
Control shield of the 2nd degree of automation (AVR) AD-320.2 (SHAU-320.2)

The new domestic domestic equipment proposed for the supply, non-operated, non-removed from production. The equipment complies with quality, packaging and labeling standards. The quality of goods is confirmed by the passport of the manufacturer, all-Russian certificates of conformity. The equipment is tested under load, if necessary, appropriate acts are drawn up.

In 2018 In the energy system of our country, more than 200 accidents were recorded, which led to a violation of a normal power supply regime of industrial enterprises, socio-administrative facilities, the private sector. In the absence of an electric current generator of diesel or gasoline type, electricity supply interruptions lead to significant damage in all fields of management. The most significant financial losses are carried enterprises whose work is associated with a consistently high energy consumption, for example, for heating by melting furnaces, hot water systems, etc., which is why the number of industries are growing every year, the leaders of which are considered appropriate to order an automatic diesel generator that performs the function Source of backup power.

How to choose a diesel power station

Creating stable conditions for the work of electrical equipment, lighting systems and communications requires the presence of diesel generator power plants. Thanks to a wide choice and an acceptable price, buy a diesel generator can be taking into account all the needs of the electricity.

Choosing diesel generators (DSU), the power plants are assessed by the following factors:

  • solved task;
  • engine manufacturer;
  • required power;
  • number of phases;
  • terms of Use.

On the pages of our site you will find all the necessary information that allows you to order diesel power plants, the necessary power (in kW) and including various options: heated coolant, external battery charging, autorun, etc. There are 3 variants of the DSU, which can be installed on various objects, taking into account their features.

  1. Opened DES. It is suitable for installation in the room, subject to the compliance with the requirements for ventilation, gas engine and fuel supply system.
  2. DGU in a protective casing. It can be installed both in the room and on the street. The housing reduces the noise and protects the engine and other assemblies from precipitation and temperature drops.

Diesel power station in the container. Installed if it is impossible to allocate a separate room for DSU and, if necessary, provide convenience of maintenance and guaranteed launch at minus temperature.

Complex services in the field of energy supply

The main activity of our company in Moscow is the sale of equipment that provides autonomous energy supply, which includes a diesel-generator power plant. We are comprehensively approaching the task solving - from the development of an individual project before installing DES and service. Experience and qualifications of our engineers allow you to choose the optimal solution for specific objects, taking into account technical and economic queries. The selection of equipment and components is carried out with regard to the budget of the customer, but we are ready to apply flexible pricing policies.

48% "STYLE \u003d" WIDTH: 48.76%; Border-Collapse: collapse "\u003e

The company has developed and serially produces diesel power plants with a capacity of 30 kW. In combination of reliability and maintainability of the MMZ engine under heavy operating conditions with high quality electricity efficiency, Leroy Somer (France) is an optimal solution for autonomous and backup power supply of consumers. As the main sources of power supply are used for autonomous objects (remote settlements, construction sites, deposits, watches, drilling rigs, etc.). As backup sources of power supply can be applied at objects requiring increased reliability. power supply (Industrial enterprises, educational institutions and medicine, banks and financial companies, hotels, etc.)

The company offers an embodiment and installation of diesel generator sets (DSU) the most fully appropriate operating conditions on the territory of the Russian Federation. This is a block container type "North" production. It is an all-welded insulated container, inside of which the DSU is installed and all the peripheral systems are mounted (lighting, heating, ventilation , fire and security alarms, fire extinguishing system, cable communications, gas-owned system ...) for normal DSU functioning.

Name of parameter

Value

Standard equipment

Rated power kW / kva

Maximum power, kW / kva

Skin (variable)

Rated voltage in

Nominal frequency, Hz

Nominal power factor

Rated current, and

Engine shaft rotation frequency, min-1

Fuel system, l

Cooling system (radiator / engine)

Lubrication system

Fuel consumption at 100% load, l

Specific oil consumption,% of the flow rate

Min. Tever. launch without heating, 0c

Overall dimensions, mm (for x width x high)

Mass of dry electric unit, kg

three phase

MMZ engine d-246.1 without highcharge with starter

Leroy Somer LSA 43.2 S15 generator 32kW

Inlet system with a dual air filter;

Gas flip system with a silencer of noise;

Fuel system system with built-in fuel tank capacity of 90 liters. with fuel filters;

We hope for long-term cooperation !!!

It is profitable and convenient to work with us !!!