Repairs Design Furniture

Danfoss thermostat for heating radiator instruction. Overview of thermostators from Danfoss. By type of heating systems

Installation on the thermostat radiator is the ability to reduce the cost of heating, improving the microclimate in the house, as well as the maintenance of Earth energy resources.

The motives can be different, but the decision is incarnated in life more and more.

Many, choosing equipment manufacturer, stop at Danfoss.

And not surprisingly, the products of the famous brand are easy to meet on the shelves of many stores.

The production technology of their thermostats based on a gas-filled bellows is patented and applied at its own company plants. If you also decided to purchase a Danfoss thermostat, the installation and operation instruction will be by the way.

The goal of the installation of the thermostat is maintaining the selected by the consumer, the air temperature in the house.

The design of the thermostator for radiators includes two elements, complementary by each other:

  1. Thermostat (or thermostatic element).
  2. Danfoss thermostat valve.

The valve is connected directly to the battery, and the thermostatic element is installed on it.

Basis base is a thermostat. It is he who reacts to a change in the ambient temperature and affects the valve that overlaps the coolant stream.

Temperature regulator Danfoss.

Inside the thermostat head - a bellows (corrugated chamber capable of changing the size), filled with gas. Gas, depending on the temperature, changes its aggregate state (chilled it condensed). This leads to a change in volume and pressure in the chamber. The camera decreases in size, pulls the stem of the spool, which opens a greater clearance in the valve for the receipt of the coolant.

When heated, the reverse process of expanding and overlaping the lumen occurs (adopted standard - 2 V ° C of excess air temperature over specified).

When a comfortable temperature is displayed on the regulator scale, a certain compression of a tuning spring is established inside, which is interconnected with a certain gas pressure.

Danfoss produces gas bellows inside, as well as liquid. The latter are more inert, react to a change in temperature slower.

Types and symbols:

  • RTS - liquid bellows;
  • RTD-G is a gas beam for a single-tube system, or two-pipeless without pump;
  • RTD-N is a gas beam for a two-pipe system, and systems with a circulation pump.

Danfoss Radiator Regulators RA 2991

There are also modifications of thermoelements in which:

  • Protection from reconfiguration with random persons (a great option for public institutions and children's rooms).
  • There is a remote thermal sensor, connected by a two-meter capillary tube, which can be installed away from the radiator, blown into a niche or forced furniture, which gives a more accurate measurement result.
  • With a range of temperatures, slightly less than the conventional sensors, to integrate into the system where payments are made by standards.

Extraction electricity from the Earth is interested in many people. - How to get your own hands, read in the article.

Formulas and examples of the calculation of ventilation of industrial premises can be found.

With reviews about the efficiency of electrical heating convectors, you can familiarize yourself.

Heating system of floors

Thermostators are used for the heating system of floors. The thermostat for warm floors is simply necessary!

After all, driving fluid into the floor circuit, you need to lower its temperature from 60 to 90 in ° C, to a comfortable 35 - 40 V ° C (while the surface of the floor itself will be about 25 in ° C).

Flow meters are powerless if the pressure is jumping in the system if the air heats up, for example, from the Sun, and even if the tenants want to save on heating during their absence.

Thermomechanical regulator is better to apply for small rooms, about 10 m2.

For large areas, indoor temperature regulators use with a warm floor temperature sensors.

Installation of thermostatic element

First of all, the valve on the radiator is mounted. For this, the flow of the coolant is overlap.

  1. There is a markup on the feed pipe. The site that will need to cut out should be in length correspond to the size of the valve body minus threaded connections.
  2. The heating pipe is cut, superfluous cuts.
  3. With the help of a lark, or a dice, a thread is made on the outside of the cut pipe.
  4. The compound is processed by plumbing paste and fum-ribbon.
  5. The body of the valve hills the resulting thread.
  6. Since it is impossible to twist the pipe, from the opposite side of the valve, a cape-nut-American woman twists, and then screwed (hexagoned key) into a slice of the radiator.
  7. The body of the device is screwed into its own naked nut through the rubber washer. This connection is not necessary to somehow seal, the main thing is that it is clean.
  8. After the valve is installed on the radiator, the protective cap is removed from it (located perpendicular to the pipe).

The thermal head is set to the maximum temperature value, after which it dresses on the valve with pressing (before clicking).

Installation of the sensor

As already mentioned, the remote sensor is needed if the battery is built into the wall or something closed (furniture, screen, dense curtains).

In one case of this item, a sensor and a tuning node are combined.

  1. It is best to place the device on the open (but without drafts) of the wall, at an altitude of about 1.4 m. From the floor. It is necessary to avoid places near instruments that can strongly change the temperature of the medium - air conditioners, kitchen stoves, etc.
  2. Included in the device there is a small mounting panel, which is fixed to the selected location using a pair of self-tapping.
  3. Inside the sensor, the capillary tube is mixed. It is pulled into the desired length so that the device reaches the fixed plank.
  4. The capillary tube is neatly fixed on the back of the valve.
  5. The sensor is placed on the bar by simply snatching.

Microclimate in the house and humidity of the air - two inextricably linked concepts. For home and health, read it in the article.

Which insulation for a warm floor to choose, read. You will also find general information about laying insulation.

Installation of restriction

At the heart of the work of thermostators - physical laws. Therefore, you need to remember that the conditions in which the device is located can be made some adjustments (for example, remoteness from the heat source). There are approximate tables of compliance of the regulator scale and temperature, which can be taken beyond the landmark when installed. However, after the main setting it will be necessary to "understand" its thermostat.

For this:

  1. Exhibit the temperature on the handle with the labels.
  2. An hour later, control measurements are conducted by a room thermometer at several points of the room.
  3. If the temperature is greater or less, the testimony is adjusted on the handle.

The proportionality zone is 2 ° C. If you set a temperature of 20 °, the device will hold the indicators ranging from 20 to 22 ° C.

Sensor after installation on the radiator

Two pin, which are included in the sensor, help set limitations of the minimum and maximum position of the thermoelement.

They are at the bottom of the device:

  1. To set a limit on a mark, for example "3", you need to pull the limiter and set the sensor readings at the "3" mark. The pin is then inserted into that hole, which in this position turns out to be under the rhombus icon.
  2. The second restrictive threshold is exhibited in the same way. The handle turns to the desired indicator, only the pin is inserted into the hole, which appears under the triangle icon.
You can block the regulator at a certain temperature (protects from the inadvertent failure or children's pranks).

For this:

  1. Both pins are removed.
  2. The handle is put on the desired indicator.
  3. In this position, the first pin is inserted into the hole located under the rhombus.
  4. The second pin is in the hole under the triangle.

Danfoss thermostators have many positive feedback. This is a very easy-to-use device that does not require any attention after the initial installation and settings. But the result will be a more comfortable temperature in the apartment, as well as in some cases, substantial savings of budget funds.

Video on the topic

In many countries, up to 40% of energy resources goes to the needs of ventilation and heating of buildings. It is several times more compared to advanced European states.

The need for use

The issue of energy saving is especially acute, it is relevant against the background of a constant increase in energy prices. One of the devices that saves thermal energy is a thermostat for radiators, its installation reduces heat consumption by 20%. To do this, the consumer needs to be correctly selected to the design to the heating system, as well as make installation, you can find out if you read below.

Principle of operation

The Danfoss thermostat is designed to support the constant temperature indoor. For the first time such devices began to be used in 1943. The company mentioned is the market leader in the production and sale of such aggregates. Constructively, the devices are in composition 2 of the main element, namely the thermal head and the valve, which are connected by the locking mechanism. The purpose of the thermal head is to determine the ambient temperature to adjust the impact on the actuator, the valve protrudes as the latter. It is designed to cover the flow of water that enters the radiator. Such a regulation method is called quantitative, as the device can affect water consumption that goes into the battery. There is another method called high-quality, with its help the water temperature changes in the system. This is done by name, namely, this element must be in or boiler. The Danfoss thermostat has inside the bellows, which is filled with a heat sensitive medium. It can be gas or liquid. The last variety of bellows is easier in manufacture, but does not show such speed as gas analogues, so the latter have gained so widespread. At the time of increasing the level of air temperature, the substance that is in a closed space acquires a more impressive volume, the bellows, stretching, has an impact on the valve stem. The latter move down the cone, which is designed to reduce the passage section. This allows you to effectively reduce water consumption. With a decrease in air temperature, this process proceeds in the reverse order, and the volume of the coolant increases to the optimal limit, and the Danfoss thermostat works.

Consumer reviews

Depending on which type of heating system is used, as well as the installation technology, thermal heads and valves in different combinations can be used to control water flow. If we are talking about a single-tube system, the valve should be applied, which is characterized by increased bandwidth and insignificant, according to users, the same recommendation can be used and in the case of a two-pipe samotane system, where the water circulates naturally and does not affect the forced motivation. If you decide to choose the Danfoss thermostat, then you can install it on a two-pipe system, which is equipped with a circulation pump. In this case, according to the reviews, the valve must have the ability to adjust the bandwidth. It is fairly simple, and it is not necessary to apply a special tool for this. After you decide what valve to use, it is necessary to determine the type of thermal head.

If you are interested in Danfoss - the thermostat, the installation instructions for which will be presented below, - you can purchase it at an affordable cost. Determining the type of thermal heads, you should know that it is proposed for sale in some varieties. Thus, inside may be a thermoelement. Among other things can be remote. Sometimes the regulator is external. The devices are also programmable, in this case they are electronic. You can choose and anti-vandal thermal head. According to users who chose a regulator with an internal sensor, this device should be installed only if it is possible to arrange it horizontally. Then the air in the room will freely go to the instrument housing.

For reference

After the Danfoss radiator thermostat was acquired, it is worth familiar with the features of its installation in more detail. Thus, it is completely unacceptable to install it on the radiator in a vertical position. In this case, the heat flux will constantly rise upwards, and elevated temperatures from the feed pipeline and the housing will influence the bellows. In the end, you will come across that the device will work incorrectly.

Customer Reviews on the choice of thermostat

Homemade masters especially emphasize that in some cases there is no possibility to install the device horizontally. Then it is recommended to buy a remote one that comes with a capillary tube. The length of the device is 2 meters. At such a distance from the battery, it is recommended to have a device by installing it on the wall. Buyers emphasize that not always the absence of the installation of the regulator horizontally indicates the need to purchase a remote sensor. This may be other objective reasons. The Danfoss Temperature Regulator, the principle of which was described above, cannot be installed in any way for dense curtains, in this case, of course, the best solution will be the acquisition of a remote sensor. Among other things, such a need arises in the case when there is any source of heat next to the thermal head or the hot water pipes pass. You can resort to such a solution, and when the radiator is under a sufficiently wide window sill. In this case, the thermoelement can fall into the area of \u200b\u200bthe draft. Buyers claim that if at least one of the above conditions is observed, it is best to get a remote sensor.

Installation Instructions

The Danfoss Temperature Regulator, the reviews about which are presented in the article should be installed according to a specific technology. As the first recommendation, it is an elimination of the installation of the thermal heads on the heater within visibility. Regulation should be subject to battery whose total power is 50 percent and more from all that are in the same room. Thus, when there are two heating instruments in the room, the thermostat should be on the same battery, whose power is more impressive. If you are interested in Danfoss - a thermostat, the setting of which is simply made enough, it can be purchased and installed. The first part of the device whose role is the valve, should be installed on the feed pipeline. If it is necessary to embed it to the already assembled system, the feed liner must be dismantled. These works may assume some difficulties if the connection is made using steel pipes. The master will have to stock material tool.

Conclusion

A fairly popular company today in the market of relevant goods is Danfoss. The thermostat (how to adjust it is indicated in the instructions) must be installed on the radiator. The thermal head is then mounted without using an additional tool. It is very easy to do at home, in addition, it will be possible to save on the purchase of consumables.

During the heating season of the account for utilities, housing is growing and stronger, and the microclimate in the apartment does not become better due to the absence of the ability to reduce the heating temperature of the radiator. There is a compact device that solves both problems: saves money consumed on the heating of the dwelling, and helps maintain the optimal microclimate indoor.

Danfoss, being the largest producer of radiator thermostators in the world, confidently solves the issue of household energy saving.

The Danfoss thermostat for the radiator is a simple but efficient solution for energy saving in the house. This makes the product relevant for the market of millions of private consumers seeking to minimize water heating costs.

Using the Danfoss thermostat, you can adjust the required temperature in any room. The device is suitable for all types of radiators (except cast-iron).

Danfoss.

Danfoss is a leading technology provider that satisfies the growing need for energy efficiency, safe for the climate of decisions and modern infrastructure.

A wide range of company products and services is used in areas such as food cooling, air conditioning and building heating. The company is actively working in the field of solar and wind energy, as well as the infrastructure of centralized heat supply and cooling.

Danfoss was founded in 1933 in Nordborg (Denmark) by the Danish industrial engineer Mads Clausen.

For more than 80 years of its existence, Danfoss released a whole series, which with the onset of technological progress became more perfect and can now be managed from a smartphone via Bluetooth.

Design of Danfoss thermostators and work principle

The main function of the thermostat is maintaining a given temperature level in the room and as a result - the competent distribution of energy resources.

Danfoss radiator thermostat consists of two parts:

  • regulating valve;
  • thermostat (thermostatic head, thermostatic element).

Both products are manufactured under various types of pipes and heating systems. Thermostatic element is removable, presented in several modifications, which in most cases are suitable for all valves.

Thermostat - The main element in the design. It is he who reacts to changes in temperature in the room and gives a signal to the valve.

Inside the thermostat is a bevel sensory to change the temperature of the beam.

Silf - It is a hermetic chamber with corrugated walls and a heat-sensitive liquid or gaseous composition (thermal AG. When heated, the corrugated membrane increases in volume, and when cooled, it is tightened back.

Inside the thermostat is a temperature sensitive element consisting of a hermetic bellows filled with liquid or gaseous composition with a high thermal expansion coefficient. When heated / cooling, the composition increases / decreases in the amount, which leads to the fact that the bellows lengthened / shortening.

The coolant, passing through the heating pipes, heats the composition of the bellows.

Stretching, the bellows presses on the rod, which closes the flowing section of the valve and presses the working cone. The latter, in turn, overlaps the flow of the coolant in the radiator. When the valve closes, the temperature in the batteries begins to decrease to the indicators installed on the thermostat.

The bellows with a gaseous agent reacts to heat change in the apartment faster than with liquid.

The coolant ceases to enter the radiator, due to which the battery begins to cool. The air temperature in the room is reduced. In the meantime, the corrugated walls of the bellows with an inert substance are gradually cooled and returned to the previous state. The pressure on the working cone is terminated, the valve opens, and the radiator heating again.

The principle of operation of the thermostat consists in constant repetition of the heating cycle and cooled a heat agent.

The structure and types of thermoclap

In structure, it looks like a valve crane, so the principle of its functioning is very simple. The thermoclap is designed to regulate the temperature of the coolant in the hot water supply system.

Types of valve

In its purpose, the valves are divided into:

  • mixing (mix hot and cold water);
  • separating (divided into separate streams);
  • switching (switches streams).

By type of installation:

  • straight,
  • angular,
  • for the right installation on the radiator,
  • for the left installation on the radiator,
  • three-way.

The three-way valve redirects, mixes and divides the working flow of the coolant in the pipes.

By type of heating systems:

  • for a single-tube heating system,
  • for a two-pipe heating system.

By type of materials:

  • from bronze,
  • from brass,
  • stainless steel.

As an additional protective coating, the valve nickelate or chrome.

Danfoss thermostat valves are divided into two types:

  • for two-pipe pumping heating systems. Official name - RTR-N (RA-N);
  • for single-tube pumping and two-pipe gravitational systems. Official name - RTR-G (RA-G).

RTR-N valves have a conditional diameter from 10 to 25 mm. RTR-G. - from 5 to 25 mm.

The gravitational (natural) water heating system differs from pumping (forced) by the fact that the circulation of the coolant inside the heating radiator occurs due to the effects of gravity force. The pumping system also assumes the presence of an electrical pump.

Types of thermostat

Heating thermostat heads exist three types:

  • manual
  • mechanical
  • electronic.

Manual thermal heads They have a valve, which when turning the handle adjusts the flow of the coolant.

Mechanical Have a more complex structure and can maintain the specified temperature in automatic mode. The principle of operation of such a thermostat consists in heating the bellows and adjusting the supply of the coolant.

Installing the mechanical thermal heads is not always possible, for example, if the battery is closed or completely built into the wall. In such cases, thermostat is used with a remote sensor to make it easier to adjust the flow of the coolant.

The thermostatic element is connected to the temperature sensor using a special capillary tube.

It will measure the air temperature in the room. If the temperature rises, the sensor will transmit a signal through the capillary tube into the bellows. Then there will be a cycle of the heating of the bellows and the subsequent cooling.

Such thermostators differ from hand-made increased cost, but it happens more precisely, without serious errors (± 1 ° C).

Electronic radiator thermostats Size a little more than their predecessors. Such thermal heads from the batteries work, and the interaction with the rod occurs due to the built-in microprocessor.

Electronic models have a set of additional features, such as a timer. At the moment when there is no one in the apartment and there is no big need to warm the room. You can program a reduced temperature indicator, and by the time of return - to set the temperature above.

Types of conjunction design

In addition to thermostatic heads and valves, the package of the thermostat includes special adapters, which provide the ability to set the thermostat to various types of valves.

Choosing a thermostat on the Danfoss battery for the radiator, it is necessary to take into account all the characteristics, including the size of the valve bouncing. You can pick up the Danfoss thermoclap under the desired thermostat or order a ready-made kit.

Temperature regulators on Danfoss battery: what happens

Danfoss radiator thermostators are available with embedded and remote sensors to ensure optimal functioning and comfort management. The large range of valves and additional equipment will allow everyone to install the thermostat in its apartment.

Danfoss thermostats are modified by the built-in or external air temperature sensor in the room. As an additional function, you can equip the device with a protective element from unwanted reconfiguration.

Danfoss thermostats: model range

For its considerable history of existence, Danfoss has released many models of thermostators, many of which are updated and reissued to this day.

The most popular models are the thermocons of the series:

  • RTR 7000,
  • RTRW,
  • RTRW-K,

Thermostat RTR 7000 (RA 2000)

Thermostats of the RTR 7000 series Have options with built-in and remote air temperature sensor. The design is specifically designed for RA radiators. The capillary tube of the latter in length reaches eight meters. Special outer casing protects the thermostatic element from external negative impacts. Almost all series models have a gas beam, a valve overlapping function and freezing protection. On average, from +5 to +26 ° C.

The series includes such models as: Danfoss RTR 7090. with built-in sensor, RTR 7092. with a remote sensor RTR 7094. With a protective casing.

RTRW thermostat (RTRW)

RTRW series thermostators There are not so many differences from RTR 7000. Contain a liquid agent. Also available with a remote and built-in sensor. Temperature setting range varies from + 8 to + 28 ° C.

The RTRW type includes models: RTRW 7080 with a built-in sensor, RTRW 7082 with a remote sensor.

Thermostat RTRW-K (RAW-K)

Thermal heads RTRW-K Present a virtually a copy of the previous thermostatic element. The difference is that RTRW-K is more versatile and suitable for many types of heating batteries, including: steel panel radiators type Biasi, Delta, Dianorm, Diatherm, Ferroli, Henrad, Kaimann, Kermi, Korado, Purmo, Radson, Superia , STELRAD, VEHA, ZEHNDER-COMPLETTO FIX.

Temperature setting range from +8 to +28 ° C. The device is equipped with the possibility of protecting the heating system from freezing.

The RTRW-K series includes: RTRW-K 7084 with a built-in sensor, RTRW-K 7086 with a remote sensor.

Thermostat RAX

Thermostatic head of the RAX series - It is a thermostat with a liquid integrated temperature sensor. The elegant design of this product is harmonized even with the most exquisite interior. The distinctive feature of the RAX is the setting scale with Roman numerals. Temperature setting range From +8 to +28 ° C.

The series has several modifications in the color range of the case: white, black, chrome and steel.

This is an electronic smart Danfoss temperature regulator. The device automatically maintains a comfortable air temperature in the range from +5 to +28 ° C.

This model is a novelty in the world market among thermostators, which works from the batteries and has the ability to control the smartphone.

The thermal head for the heating radiator Danfoss ECO is equipped with such functions as the definition of an open window, automatic tuning and autotest valve.

For example, if the air temperature in the room sharply decreases (the stream of cool air from the street), the valve will automatically close in order to avoid heat loss. The heating of the room will renew again when the window is closed.

The first week after installing the device is calibrated and "remembers" the moment in which the room heating should be started to achieve the desired temperature to a specified time. In order for the control valve to be blocked by time, once a week, thanks to the smart processor of the device, the valve will be fully opened for automatic flushing.

The device also involves the mode of night and daytime decrease in temperature, and includes all the functions of its predecessors.

The pledge of strong sleep is a comfortable air temperature in your bedroom. Danfoss Eco can be programmed that at night the air temperature in the bedroom will be slightly lower, and closer to the morning will increase and make your awakening more pleasant.

  • living room - +21 ° C,
  • kitchen - +19 ° C,
  • bedroom - +20 ° C.

You can purchase Danfoss Eco on the site website. Here are three options for the configuration of the goods:

Danfoss Eco Temperature Regulator for Magicair DANFOSS ECO + Basic Magicair Station 2 DANFOSS ECO Termoregulator + Basic Magicair Station
If there is already a basic Magicair station, having a serial number of format 310030.xxxxxxxxx or 310040.xxxxxxxxx If there is no basic station Magicair If the room has two heating batteries
  • Free app
  • Maintain a given temperature
  • Work on schedule
  • Function "Protection against Children"
  • Battery charge indicator
  • Adapters in the kit

Price 3 490 ₽ When buying a configuration with Magicair

  • Free app
  • Maintain a given temperature
  • Work on schedule
  • Function "Protection against Children"
  • Battery charge indicator
  • Adapters in the kit

Basic Magicair Station

  • Free app
  • Maintain a given temperature
  • Work on schedule
  • Function "Protection against Children"
  • Battery charge indicator
  • Adapters in the kit
  • Management from anywhere in the world
  • Favorable price Danfoss ECO 3 490 ₽ When buying with Magicair

Basic Magicair Station

  • Microclimate Monitoring: CO 2, Temperature, Humidity
  • Automatic control of climate appliances from a smartphone
4 490 ₽.
13 390 ₽
16 900 ₽.

Installing the Danfoss thermostat

Danfoss thermostators are installed at the inlet or at the outlet of the heating battery. Installation of the device does not have difficulties, the installation principle for each model is the same. An important point that is worth considering first is the definition of the necessary height. The recommended height indicates the technical characteristics of the device.

Each thermostat of Danfoss still has been calibrated under control of air temperature at a certain height. Most often, the instructions for the device describe the installation in the upper collector of the radiator.

If the pipe has a bottom in the apartment and there is the possibility of only the bottom saddle connection, in this case you can try to purchase a thermostat with the possibility of lower connection, install the device with a remote sensor or recalibrate the thermostatic element (Recommendations for the thermostat to reconfigure the thermostat in the model passport).

Mounting the Danfoss Eco thermostator does not require tools or special skills, so its installation can be organized independently. If the radiator is not equipped with a built-in valve or there is a conventional ball valve, the installation of the thermostat is better to trust the controlling company specialist who will take into account all the nuances of the installation and features of your heating device.

During the heating season, the installation of the thermostat will require the overlap of water in the pipes, which can entail the disconnection of heating in the neighbors (in the case of vertical heating wiring). In this case, you must send a request to the management company to disable heating at the time of installation of the device.

It is important to pay attention to the details:

  1. Immediately before installing the equipment, turn off the radiator from the heating system and drain the water from the battery. (In advance, install floors with towels, tissue wipes or newspapers).
  2. When installing a new adapter for the valve, the internal thread is cleaned and turned into a special tap ribbon, which can be purchased at any plumbing store.
  3. Installing the Danfoss thermostat for all batteries indoors ineffective. The heat flux control must be exposed to the instruments whose power is at least 50% of the power of all heating batteries (if two or more radiator are installed in the room).
  4. Cast iron batteries are heated longer and longer hold heat than other radiators. The thermostat equipment in the case of the cast-iron radiator is most often ineffective.
  5. The temperature controller on the Danfoss battery has fragile parts whose damage can disrupt the functioning of the device. Installation should be carried out with special attention, not allowing the drop in the device.
  6. Set the valve is strictly in accordance with the arrows specified on its enclosure. The coolant stream must go through the arrows (accurate information in the directions of the arrows is indicated in the installation instructions).
  7. The cap of the valve (in the Danfoss red thermostators) has a protective function, it does not affect the adjustment of the heat supply power.

Temperature Management: Question Price

Temperature regulators have adequate cost and pay off during the year. To assess the benefit of the installation of Danfoss in an apartment or the house, it is worth noting that the term of operation of the thermostat, subject to the correct installation, not less than 25 years.

The prices of thermoelements vary in the range from 1,300 to 4,500 thousand rubles. The cost of full configuration (valve and thermal head) does not exceed 16 thousand rubles, the initial cost of simple sets is from 1 500 rubles. The price variation depends on the models and the presence / absence of an additional headset.

In conclusion, it is worth noting again that Danfoss has established itself in the global market as a company responsible for control, quality and energy savings in the house. The devices intended for rational consumption of power of heating systems are now in almost every home, and some developers initially laid the possibility of installing thermostators into a common project.

The thermostat for the Danfoss heating radiator is endowed with a significant list of useful features that will allow users to easily configure the comfortable microclimate in the apartment or office.

Danfoss Eco will become another advantage of your smart home, and the Magicair smart microclimate system will simplify the control of the thermostat and other smart climatic devices in the Arsenal of your life.


The Danfoss temperature regulator is a device that is widely used in various home and industrial heating systems. Such samples are distinguished by high quality, accuracy and convenience of work.

Let's study their features in more detail so that you have the opportunity to use these perfect mechanisms and for your systems.

Description and appointment

The Danfoss regulator is a device that is used to adjust the air temperature in the room. Such a device can be used in various systems of heating, including in such where water is the thermofer.

Regulator Allows you to manually control the operation of such a system, economically spend heat, as well as turn on and off all heating. The thermostat is used both in home networks and in closed greenhouse ecosystems, or in production. It is also used to work refrigerators, air conditioners and other systems in which it is important to observe the temperature regime.

1.1 Danfoss Temperature Management Device

Danfoss regulator, regardless of its design. It is a small chamber filled with gas or liquid. This liquid or gas is exposed to temperature, presses stop valve In view of which it stops the flow of heating fluid into the radiator, due to which the system increases the temperature.

When cooled the room, the liquid is compressed and the reverse reaction occurs. Such a system of work is valid for all types of radiator , among other things, products for refrigerators. According to this principle, almost all products of this manufacturer are operating, including Danfoss RTD and Danfoss RA rules, as well as many others.

2 model range of Danfoss thermostators

Danfoss has a fairly wide range of thermostators. Currently, these products include such varieties of devices:

  • temperature regulators for design of model range regulators 013G4001-013G4009. Applicable for heated towel rails, as well as various sections of heating networks. Produced in versions for the right and left-sided installation;

  • Danfoss RTD 3640 is a variety of models for heating systems. Designed for a two-pipe standard system. Have RTD protection function from freezing for the winter. This species is suitable for home, industrial heating systems, but not for refrigerators. It has only 4 divisions, designated as Arabic and Roman numbers;

  • rAX models with liquid filler. This series is also intended for heated towel rails and design radiators. The model is applicable for most modern versions of design radiators, has divisions with both Arabic and Roman numerals;


All presented versions of thermostators are accompanied by a whole series of special accessories that simplify their installation, as well as further use.

Almost all thermostators released in this series are represented in three different versions: goldist, white, silver. You can choose the type that matches your system, the valve and the temperature jakela work they have almost the same.

2.1 How to install Danfoss thermostat?

The Danfoss regulator is mounted directly on the hot pipe feeding your heat supply system. Installing any model, including RTD 3640, RA, is not complicated. Work in this case will have this way:

  1. Turn off the system from the total power, cut off the pipe of the desired size to install the thermostat. Without this step, the installation is not carried out.
  2. On the existing nozzle, we make a thread with the help of special devices to which the thermostat will be installed.
  3. We process the plot of plumbing paste, and already fastened the housing of the valve RTD 3640, RA or any other.
  4. Connect the device itself to the valve, tightening the puck connection. Additional sealing is not needed here.
  5. We remove the fuse, build the thermostat to the maximum value of 5, then we put the cap with the scale on it. It is important to install before clicking for the maximum dense and high-quality adjacent.
  6. Once again check the sealing of the system, after which it can connect it back to the overall supply system. Let the valve appear once and closes, and you will be sure that the equipment works correctly.

Installing RTD, RA or other models completed. Now you can freely use the device.

2.2 How to configure Danfoss thermostat?

Setting up such a device as a RTD regulator, RA Danfoss is quite simple and available for all users. In order to implement it, you need to explore the temperature scale existing in the end (it can differ somewhat depending on which version you use). Then set the temperature you are interested in, simply by moving the pointer on the device you need the parameter.

You can also choose intermediate values \u200b\u200bif they arrange you. After a few minutes, the valve is rebuilt into the right position, and the temperature in the apartment will come to the desired parameter, and you can enjoy the most comfortable microclimate for you. Similarly adjusts the valve and in models for refrigerators.

2.3 Danfoss thermostat and its types (video)