A double-circuit gas boiler does not turn on hot water. Why the boiler stopped warm water - causes and ways to solve. Possible ways to solve the problem

Cats on cold batteries do not sleep.

Faults of the boiler

Typical problems with the operation of heating equipment:

  • fault of the built-in pump;
  • heat exchanger clogged;
  • the three-way valve is triggered.

If the boiler works, radiators are cold, experts recommend, first of all, to estimate the technical condition of the main heating element. More specifically, install whether the built-in device works . This part is the constant attribute of modern equipment and is designed to increase its efficiency. Very often, after a long in time in the summer, the pump can clog out or be covered with a layer of lime plaque. As a result, it is untowning to divert the heated heat exchanger coolant. The boiler is boiling, and the batteries are cold.

Independently repairing such complex equipment as a boiler, strictly prohibited. In this case, a specialist from the service center is either called to the house, or a repairman having a corresponding certificate or permission.

Specialists do not recommend using ordinary, tap water as a coolant, as it is tough. Dissolved salts when increasing the temperature of the coolant settle on the heat exchanger. As a result, the following problem occurs: the boiler works, and the batteries are slightly warm. Scale reduces heat exchanger thermal conductivity, so water in the circuit is not heated, although the heating element is constantly working with an energy source. It is possible to fix the problem, replaces the coolant and reading the heat exchanger. How to clear the heat exchanger correctly, will help to figure the video:

A double-circuit boiler warms water, but does not warm the battery. Here you need to pay attention to the health of the three-way electric valve. It is responsible for switching the bypass from the heating circuit mode on the DHW and CO mode.

Heating Control Problems

The pump must be selected according to the requirements of the heating circuit.

Not always failures in the operation of the heating circuit are associated with the malfunction of the main heating element. If the boiler works, but does not warm the battery, the reason must be sought in the wiring itself.

List of main faults Heating Contour:

  • the filter on the return or needle crane (Maevsky's crane) clogged;
  • insufficient power of the circulation pump;
  • the rules for mounting the contour of heating with natural circulation are not complied.

Any of the above problems should be solved before the start of the heating season. Otherwise, the room can remain without heat for several days, as the repair provides for a complete drainage of the coolant.

So why the boiler does not warm the battery if for the previous years everything worked fine? The reason is a mud tube that formed the heating loop on the filter and is completely overlaps the coolant current. It is solved simply - water from the pipes merges or with the help of bypass, its circulation overlaps, the filter is cleaned. To prevent a repetition of a similar situation, it is necessary to complete the replacement of the coolant with parallel .

In the gravitational system, the tilt of the pipes is key.

The second reason why the boiler works, and the batteries are cold - this is the insufficient power of the circulation pump. The performance of the device is missing in order to timely and efficiently pump the entire volume of the coolant. Or in the house the heating system has branches that are at a substantial distance from the pump. As a result - the circulation pump overheats, the heating equipment works with an energy overrun, and radiators remain cold. Solution - Note the pumping coolant device to more powerful.

If the house is a two-pipe heating circuit with a natural circulation of water, and during the heating season often notice that the boiler is turned on, and the batteries are cold, then the reason lies in non-compliance with the linker. According to the regulatory documentation, only the slope of the pipes are equal to 10 mm for each traffic point meter in the system of heating with natural circulation will ensure normal movement of the coolant. As a result - uniform heating batteries throughout the house. If the slope is not, there is a stagnation of the coolant, which adversely affects the temperature of the radiators. It is possible to solve the problem, completely converted a wiring.

Why is the cold batteries when the boiler works?

The low efficiency of the heating system may be the result of faults, both the contour itself and the main heating element. In the case of a heating device, it is necessary to pay attention to the three-way valve, the functionality of the pump and the technical condition of the heat exchanger. Typical problems for the heating wiring are a zago on the filter, insufficient power of the circulation pump and the absence of a slope of the contour pipe with the natural circulation of water.

One of the problems that can happen during the use of a double-circuit boiler. The boiler does not warm hot water. The main and most common reason why the boiler warms the water badly, it will score a heat exchanger.

In this article, I will describe how I fly this problem. Thus, you can go out of the situation and you, if you have a double boiler with a lamellar heat exchanger.

I have a well house and water is very tough on this constantly arise problems with hot water to correct the situation I use citric acid.

The task is. As with the smallest efforts to deliver this acid to pose the heat exchanger. I found such a way. At the entrance to the boiler, I have a magnetic converter, which should remove the rigidity of water, but it does not remove it, in my opinion it is a fiction. But for me it is good what it is installed right at the entrance to the boiler. In the photo in the bottom can be seen.

It is worth the American Nut that unscrewed which can be filled with citric acid into pour pipes.

But for this you need to overlap water. Next to the boiler I have a collector. He is in the photo below.

Now all the ducts are open on it and one light movement I overlap the flow of water into the boiler.

All water is blocked, now you can unscrew the American on the magnetic filter. And do not forget something to come up with something from the current water from the boiler, it is not much but it is. I made a rag.

Then inside the pipe, I fall asleep citric acid.

Spinning back an American and open a tap of supplying tap water to the boiler.

It is now important to understand when the acid gets into the heat exchanger. Since I have a plumbing crane in a meter from the boiler I define whether the acid in the heat exchanger to taste. Just with short jerks, I open a crane and trying to taste, how the "cit" means "means the entire system from the magnetic filter to the crane is filled with citric acid.

Next, you need to block the faucet that your homemade does not merge all the acid ahead of time.

I refuel the system for the night and until the morning it stands for me. In the morning I open a faucet of water supply to the boiler and drain all the acid. Water will hiss, not Pugaytes.

Maybe there may be a question, not the heat exchanger project? I drove on the forum of chemists and came to the conclusion that organic acid (lemon treating it) is harmless to copper.

I use this way as necessary. If you do not like the boiler warms the water or the head of hot water has become weak, I take and treat the heat exchanger lemon acid.

If you have eyeliner to the boiler from polypropylene, and it's not where to fall asleep with an acid, then think up that it does not take much time.

Reading time: 2 min

Gas boilers are designed to create comfortable existence conditions. Dual-circuit units provide residential premises with warm and hot water in the crane. But it happens that the working boiler warmly warm water and does not give the necessary comfort.

From how the boiler works, the degree of efficiency of the entire heating system depends. If malfunctions in the gas boiler itself, it may adversely affect the efficiency of the entire system and be the reason for excessive energy resources.

What happens when the boiler stopped warming the water? We will analyze the causes and ways to solve this problem.

How does the boiler work?

For a clearer understanding of the situation, it is necessary to understand the principle of operation of the boiler. Such two-integral gas wall boilers, like "Baksy" or "Ariston" consist of several components. In the gas part there is incineration of the incoming fuel, the water part is supplied to the heated water from the heat exchangers to the heating system, part of the smoke removal is responsible for the removal of burning products outside the dwelling.

After starting the boiler, the pump is turned on, providing the required water level in the system and the gas supply valve opens. The coolant moves in the heat exchanger, which heats up the flame of the burner. The thermostat is monitored by the temperature mode in the room, the temperature sensors control the readings on the feed and return pipelines. Also removed fuel pressure, coolant in contours, the presence of thrust and burning.

Depending on the user settings, the temperature sensors set the water heating mode. The sensor on the return pipe turns off the boiler, depending on the achievement of the required temperature set for reverse. However, the system pump does not stop working until the heat exchanger temperature decreases.

This is provided for not water boiling in it. As soon as the cooler cooler will occur to the limit level, the electronics will send a signal to turn on water pumping and gas valve. The whole process will begin again.
When you open the crane in a mixer in a two-kite, the flow sensor reacts that the electronics reports the need to switch the three-way valve to the water heating mode for the DHW.

When the hot water crane is turned off, a reverse transition to heating is turned off. Some manufacturers provide for the heating of both heat exchangers at a periodic switching.

The boiler does not warm water for heating

So, consider the main reasons why a gas boiler does not warm water for the heating system and what to do with this:

  • airlock. You need to examine the heating system for the presence of air in radiators. To eliminate such a problem, you need to install the air vent. The principle of its work is similar to the work of the expansion tank, but it is able to maintain pressure in the system. Using the air droplets need to release air from the system. It is important to inspect the valve itself for the presence of a mechanical blockage - the presence of scale is possible;
  • corrosion in radiators. It is possible to determine the zero of the heating devices by draining water from the system. If the water flowed dirty, then you need to appear visually clean water;
  • connect errors. Hot water may not act if the diameter of the pipes is not as provided for by the project or instruction. It is necessary to check the compliance of the pipeline, the correct connection and quality of the installation of the shut-off valves;
  • insufficient pressure on the network. You should try to add water to the heating system, as it may not have enough pressure to respond to the burner ignition automation;
  • the presence of scale in the heat exchanger. The first feature is a long heating of the coolant and heating the batteries. It is necessary to get rid of deposits and carry out boiler treatment of water. To do this, disassemble the boiler, and dismantle the heat exchanger knot.

Before that, it is necessary to overlap the flow of gas and water to the instrument. Then the flexible connectors from the pump are connected to the heat exchanger and it is washed with a composition with a special treatment agent that can be purchased in free sale. After that, the parts are washed with water.

It is important to understand that the addition of chemical reagents to the coolant warns and reduces the appearance of deposits on the details. But before using the reagents, you need to read the instructions of the boiler, as some manufacturers, such as Ariston, Electrolux, Budyrus, Navien or Ardery, do not provide for the use of chemical additives to the coolant. In this case, water purification filters or distilled water can be used.

Some manufacturers allow the use of antifreeze instead of water in the heating system. This substance can be used in the following boilers: "Baxi", "Vaillant", "Proterm", "Beretta", "Korea Star". However, it should be understood that each manufacturer recommends using antifreeze of its own production;

  • filter clogging. When clogged with filter meshes with mechanical garbage, radiators can also warm well. Therefore, the filter should be regularly checked and cleaned, washing with water. If clogging takes place too often, then such a detail is replaced;
  • incorrect setting. First of all, with a weak or missing heating, you must check the control unit settings. Insufficient temperature can be installed and the gas does not heat water;
  • failures in the operation of pumping equipment. If the pump power is not enough to provide good circulation, then it can turn off when overheating. This can occur when the DHW circuit is turned on;
  • incorrectly selected heating devices. If the system has radiators with unsuitable heat transfer and structures, it can also lead to weak heating;
  • wrong bias pipelines. Most often, this problem is found in systems with natural circulation. Regulatory documentation determines that the bias of pipes must be from 10 mm for each meter of the pipe. In case of non-compliance with these requirements, circulation can be broken and, as a result, there is no heating due to the low heat transfer duct.

The boiler does not warm water for hot water supply

In addition to the lack of heating the heating system, it happens that the gas boiler does not warm the contour of the hot water supply.

The most common cause of this negative phenomenon is the critical formation of scale in the heat exchanger.

After all, scale has a structure that restricts the passage of the coolant, as well as the heat taken it. This is due to the thermal conductivity of salt sediments - it is much lower than the thermal conductivity of the metal, from which the heat exchanger is made. Therefore, the boiler is bad warm hot water.


An option is also possible when a piece was deployed from salt deposit, blocking the duct completely, which leads to a complete cessation of hot water supply.

The next reason that the boiler does not heat the water is the failure of the duct sensor.

Constructively, the sensor is a paddle device through which water flows, which is the condition of its operation, because it gives a signal about the presence of a flow to electronics, which, in turn, starts heating the water again. It happens that the sensor is clogged, but it can be cleaned from the crowding without removing.

The device has a cylinder form and is located near the circulation pump. To start cleaning, you should open and close the crane near the sensor. In case it does not help, it should be turned off and removed, clean it manually and install in place. If it does not help, the sensor is most likely faulty and need to be replaced.

The reason for the lack of water in the DHW circuit can serve as a faulty trotter valve.

It is designed to overlap the heating system when opening the hot water crane on the mixer. If the valve does not work, the boiler does not switch to water heating for DHW from heating water for heating. The first cause of its breakdown may be a blockage of corrosion products from which you need to get rid of.

In case it does not help, the valve should be replaced. It is also possible to pollute the hose system and filter. This problem is barely noticeable on the heating circuit, and on the contour of the hot water supply it will be noticeable more. It is necessary to clean these elements.

If Gas boiler does not warm water For hygienic or general technical needs, the problem can be solved by heating the required amount of fluid in a saucepan. Much more problems will arise in winter when the heating system is blocked. With a long lack of hosts, freezing system is possible. Subsequent restoration of its performance is associated with significant financial and temporary costs. To eliminate such negative situations, it is necessary to choose and apply a complex of effective preventive measures.

Design features of the bucki gas boiler (BAXI), Navain, Ariston

In any case, familiarization with the technique of this class and the peculiarities of modern models are useful. These knowledge will help you choose the hardware correctly, do not make mistakes during operation.

In household boaches buxi (BAXI), Navien and Ariston, gas, diesel and solid fuel are burned to heat the water, use electric fuel. To fully use the potential of energy resources, heat exchangers are improved. They make long ducts of complex shape to ensure long-lasting fluid in the working area.

A relevant trend is compactness. Manufacturers offer gas boilers with square enclosures of a relatively small thickness. Some models in their aesthetic characteristics perfectly deserve placement in a prominent place.

The following feature is the introduction of automated control systems. They control the combustion process, change the modes of operation, taking into account the readings of the temperature sensors on the street and in separate rooms. When overheating, the technique turns off without intervention from the user.

It is necessary to consider carefully when the bucksy gas boiler does not heat the water. This happens, for example, when the supply of energy resources is stopped. It is not difficult to do the appropriate check even without special training.

Circulation pumps, valves, other standard nodes and aggregates rarely fail. Their designs are designed for long-term operation without compulsory maintenance. There are no moving parts in electronic circuits. Their breakdowns occur due to marriage. When complying with the rules established by the manufacturer, the resource of modern gas boilers of heating is more than 10 years.

Hanging the electrical part of the equipment is capable of throwing voltages in the power supply. To eliminate such impacts, an external stabilizer is established. It is useful to check the grounding system. This set of preventive measures for this group of problems is exhausted.

It is much more difficult to ensure protection from the most common cause of breakdowns of gas boilers - scale. It is she who studied in detail in this article. When heating, calcium and magnesium salts are converted into a solid state. It is these impurities that clog the narrow technological holes in the heat exchangers. They also form a porous structure on the surface of electrical heating elements. With a significant violation of the normal removal of the heat of their housing is damaged.

To prevent the formation of scale and lime inside the boiler, it is advisable to install non-chemical filters (water converters), magnetic and electromagnetic, which will provide a long "life" of your boiler and uninterrupted hot water supply, as well as protect the heating circuit.

Such filters (scale converters), as the scrawl or MWS, do not use chemical reagents and replaceable cartridges in their work. Once by installing such a device in front of the boiler, you will forget about the problem of scale for many years!

Troubleshooting: Why does a gas boiler warm hot water?

If the gas boiler is badly warming up hot water due to clogging or breaking the tube in the heat exchanger, repair is needed. It is performed by replacing the failed node. Threaded connections are not used in this case, so it will be difficult to disassemble independently and the subsequent installation will be difficult. To create a high-quality connection, the soldering is better to invite an experienced master. A qualified specialist will provide the necessary level of quality, will provide written guarantees.

You do not just know about the problem. A layer of scale grows slowly, so it will not be possible to register a clear reduction in power. Foreign noise can be caused by the passage of sand pipes, other mechanical impurities. Technological holes are too small for visual inspection. It requires dismantling.

These information is explained why emergency situations of this type occur unexpectedly. To prevent their development in a more complex problem, you can equip the boiler equipment with a modern remote control system. Some manufacturers offer ready-made solutions in the form of an additional electronic unit and specialized software.

The appropriate application is loaded onto a smartphone. The advantage is the ability to remote change settings, checking the temperature sensors. If the gas boiler is not warming up hot water due to scale, the heat exchanger replacement is not enough. The same pollution reduces the inner diameter of pipes, narrow the ducts in radiators. Full cleaning system is needed.

This procedure is performed according to the following procedure:

  • Drain water drainage.
  • Wash all contours successively, or at the same time special solution.
  • It is used to clean the heat exchanger, if only clogged and can be operated further.
  • After assembly, the performance of the pressure system is checked.
  • Eliminate identified defects (cracks, loose compounds).

To remove calcium solutions, or aggressive chemical compounds are used. The duration of the standard procedure for one household object is several hours. Relevant corrections are made taking into account the real state of the system. Strong acids are capable of damageing metal parts, soldering joints of the dual-circuit boiler Ariston. For this reason, experienced brigades are taken to fulfill orders tool for repair.

An independent execution of such procedures is possible. But for many ordinary users it is not advisable for several reasons:

  • You have to acquire expensive equipment for pumping liquids to be used.
  • An independent selection of the optimal composition of the solution will cause difficulties.
  • During this procedure, there are no mechanisms for operational control of processes within the system of the pipeline. This increases the likelihood of breakdowns.
  • With personal execution of operations, official warranty obligations of a third-party performer will not be obtained. All problems that emerged in the future have to be solved at their own expense.

Additionally, it should be noted that the careless handling of aggressive chemical compounds can cause harm to health.

Preventive actions

Specialists of enterprises offering flushing recommend to make every heating season. It is combined with a common inspection of equipment. Periodicity is corrected taking into account the level of rigidity, the intensity of the operation of gas dual-circuit boilers (BAXI), other significant factors.

Such tips are really helpful. Regular cleaning will prevent more complex procedures. Simultaneous check will help identify problems in the early stages. However, it is necessary to emphasize the main disadvantage of this technology - it is capable of damaging the equipment. It is especially unpleasant if defects are shown during the heating season. Prove the fault of workers who made cleaning will be quite difficult.

Instead of applying potentially dangerous techniques, effective protective measures are used. They are based on modern water treatment technologies.

So that in the heating boiler Navien or Ariston did not form scale, it is installed in front of it. They dissolve during the passage of water flow, they create dense shells around microscopic particles of scale (at the first growth stages). After such a "modification", harmful impurities can join the walls and each other. They pass freely along the contour, removed into the sewer.

The second method is to replace harmful compounds sodium ions. This procedure is carried out using special resins. They are falling asleep into two major containers that work alternately. As contamination accumulated, flushing with an inexpensive regeneration solution from the cook salt is performed. Such equipment is used for the overall protection of apartments, cottages, other properties.

Next reason why the gas boiler does not heat hot water and its decisions, it is a protective technology that has appeared recently, although known for more than a hundred years. The fact is that only constant magnets were used to treat from scale. They lose their useful properties over time. Moreover, the effect of "addiction" was experimentally detected when calcium and sodium compounds cease to respond to appropriate effects.

Nowadays, the technique is improved! Today, electromagnetic converters with high frequency oscillation generators are used. With minimal energy costs (5-20 W per hour), they operate at a distance of up to 2 km along the length of the pipeline from the installation site of the booth heating boiler or protema. This technique retains initial efficiency throughout the service life.


Ultrasound can be chopped by screaming particles, eliminate old education. But this technology is rarely used. Like acids, it is able to destroy the structural components of the water supply system. It should also be noted the likelihood of harmonic oscillations in the sound range.

Membrane technologies provide a high level of purification from different impurities, including rigidity salts. But standard household settings are treated not more than 200 liters. liquids per day. This is not enough for the needs of the boiler of the heating of Wilant and hot water supply.

Features of various technologies for cleaning the boiler and conclusions

If the gas boiler stopped warming water, it is necessary to repair it. To extend the life of the heating boiler, the Buderus or Ferroli and the prevention of accidents apply different techniques. To choose the appropriate option, you need to pay attention to the following details:

  • Washing with aggressive chemical compounds does not eliminate the problem, but liquidates the scale already formed.
  • Polyphosphates pollute water, so such protection is used only for the heating contour.
  • Sodium compounds harmless (this is an ordinary, well-purified food salt). However, after appropriate processing, water will acquire a pronounced flavor.
  • Ion exchange fillers are sensitive to temperature, humidity, various impurities. It should be clarified by the requirements that are set forth in the official instruction of the manufacturer of the double-circuit boiler Navien.
  • To connect electromagnetic converters, you need a current source of the corresponding power. To ensure its continuous work in difficult conditions, autonomous emergency power schemes are used.

When determining the reason why the Navien gas boiler does not heat, or heats the hot water badly, it is 3 ways to protect the stiffness of water, the architectural characteristics of the real estate object.

Individual heating and hot water supply has long ceased to be something unusual. It is convenient and practical, moreover, it allows you to not depend on the pleasure of utility services. Well, if some kind of trouble suddenly happens, for example, it will be found that the boiler does not heat the water, then to eliminate the breakdown will have to be forces.

No, this does not mean that you should be armed with a tool and start repairing yourself - for this there are specialized companies providing such services. If the heating boiler works properly, but it does not heat the water, then experts will repair its repair, make the boiler setting according to your wishes, and if necessary. All work will be performed qualitatively and guaranteed.

Modern gas boilers are reliable and powerful heating devices that also perform the water heating function. They are successfully combined, it would seem incompatible things - unsurpassed efficiency and compact dimensions. But their uninterrupted work is possible only subject to regular maintenance, detection and eliminating the slightest faults.

Faults of heating boilers

Basically, large faults begin to manifest themselves during the heating season, when two contour of the boiler works - heating and water heating. It may happen that it does not start at all, or he is not warm enough. With the launch, the question is to be solved separately, well, if it does not heat the water, then the reason may be in clogging the heat exchanger. As you know, the quality of water in our systems is far from the perfect, moreover, few users install in front of the boiler. So the heat exchanger is clogged, the result of which is the bad work of the boiler.

Here are the most common malfunctions of gas boilers in the event of which he is weakly warming water:

  • periodically spontaneously turns off,
  • smoking me
  • does not develop sufficient power
  • noise
  • clogged
  • pump broke.

If it happened so that the gas boiler does not heat the water, then often the reason is to form a lime-plated heat exchanger on the walls, which as accumulated becomes very durable and not only reduces the water temperature, but also reduces the capacity of the boiler. The thermal conductivity of the scale is ten times less than metal, so it is not surprising that the water boiler does not heat. If you do not take any preventive measures, then the boiler will have to completely disassemble and delete deposits to the mechanical manner.

It can only help this misfortune, and it should be done regularly, especially if the cauliflowing and softening filters are not installed before the boiler. Special chemicals are used for flushing, but they should be used with great care, since they equally destructively act on lime deposits and on the material from which the heat exchanger is made. It is best for this purpose to invite a specialist.

Preventive maintenance is recommended for safe and efficient operation of the gas boiler. It is advisable to do it regularly before the start of the heating season, you should not wait for the situation when the boiler does not warm water. Such an approach will provide the duration of its service and cost-effective work. Overhaul is made as an employee of the service center - to do it on its own it is categorically prohibited.

Wilant boilers are distinguished by special reliability and security. Cleansing such complex equipment must eliminate the master. But, small malfunctions can be removed independently if you have a basic level of knowledge about the device of heating and heating boilers.

On the boiler display, most faults are indicated. Having a decoding of errors, you can figure out what cause the boiler failure to heat the water. How to start a search if the water heating in the boiler Vailant does not work, and the indicator does not show an error or can it be interpreted in different ways?

Wilant boiler does not heat hot water due to blockage

This is one of the most common troubleshooting. Most often, the reason is in low water quality - it appears, nodes, filters and pipes are clogged.

If the flame does not light up in the boiler, start checking from the duct sensor. Find this cylindrical adaptation is simple enough. The duct sensor is located near the pump, the wires are suitable for it. Two sensors are installed near the pump:

  • Pressure sensor in the heating system.
  • Duch sensor.

The duct sensor looks like a small fan, it starts to rotate from the movement of water through the pipes. If the flow sensor fixes the movement of water, the signal comes into automation about the need to turn on gas and heat the water. If the duct sensor is clogged, water will flow, but the fan does not move. Accordingly, the signal on the inclusion of heating does not arrive. You can solve the problem in two ways:

  • Do not rush to disassemble the boiler and try the system at the beginning. Discharge the valve of the total water supply at home. Open the hot water faucet and release water from the system. Now the percentage of air has increased in the pipes. Start sharply open and close the water crane directly in front of the boiler. These simple manipulations will help create pressure and clear the fan of the duct sensor from the garbage.
  • If "purge" does not solve the problem, you need to open the boiler, unscrew the flow sensor and brush it manually.

If the boiler Wilant does not heat hot waterYou should check the secondary heat exchanger. He also has a property quickly clogged. But, fortunately, it is easy to remove, cleaned and installed back.

The clogging of the three-way valve can also cause a boiler failure to heat the water. And you can remove this node yourself, clean and install it back.

Having bought the boiler Wilant, be sure to find out from the seller Places information in which filters are installed. Clean and change these components you can independently.

Faulty pump

Water heating in the boiler Wilant largely depends on the operation of the pump. For repair or replacement of this unit, it is necessary to call a specialist. But, you can independently check whether it is the reason for the boiler failure.

Install the water temperature of 0 ° C on the boiler and turn on the water heating mode. At this time, follow the operation of the pump. If after 20 minutes of work, it will not heat up, it means that the problem is in the pump.

The reason for the boiler failure to heat the water can be in the elementary unscrewing bolts on the plots of connections. Carefully consider the boiler device diagram and check all the connections are tightly adjacent. Perhaps simple twisting bolts will solve your problem.

In this video, the solution of your problem!

See to the end and you will not need to call a specialist.

Without boiler rooms in the climatic belts of Russia, do not survive. And this applies to the warmest districts, Sochi, Anapa and Rostov-on-Don. Winters still remain harsh and without heating people do not survive. Therefore, do without heating systems and hot water will not be exactly. And only boiler houses are able to provide the city. Today we consider the reasons why boiler does not warm water - How to solve this problem and what to do for this ......

They are very different. It all depends on the heat source. They can be like steam and water. They may vary at location. If the house itself made a decision on the construction of its own boiler room, then a special room in the house can be accomplished. Or to the house under these goals an extension is made. One of the basic requirements when erecting boiler rooms is good ventilation.

If the boiler works with steam, then the quality of water purification, and then the pair is predictable very high demands. Therefore, to do on such boilers without a whole complex of cleaning installations will not be exactly. The electromagnetic softeners are also included here, which are very valued by boiler house employees today.

If the gas boiler suddenly ceased to warm the water, the reasons can be different, but most often when using water from central water supply without softening installations, the cause can be the deposits of a limescale. Moreover, solid and poorly eliminated. The table shows the possible signs of the cause of the boiler stops due to the scale formed.

Other reasons for stopping boiler are simpler. Maybe a piece of scale to get stuck in the pipe and block the normal operation, and the crack in the gas boiler can also contribute to the disconnection. But in these cases on the walls of the equipment, there will be no balance of scale. If there are no treatment facilities in the boiler room, then the root cause of course will be the rigidity of water. If the sewage facilities are standing, and the equipment check was recently, then, most likely, the problem is not in this.

In any case, if there is no cleaning in the system, you will have to urgently go to this reason and solve it. For boilers there are a number of devices that softening water that will suit:

  • Scraping;
  • Ultrafiltration and air conditioning for steam boiler rooms;
  • Ion exchange for economical consumers of gas boilers

It is a waste of everything, the process of cleansing and softening will be in steam boilers. There will have to remove not just all organic and inorganic impurities. Even dissolved gases will have to be removed. Degassing is quite troublesome and expensive. But the work of the boiler depends on the quality of the pair. Here they just work and membrane softeners to make water completely isolated.

Many consumers of gas boilers choose for the simple reason that it does not need to be careful and you do not need to spend on it. But the greatest advantage for the boiler equipment was and remains to be eliminated even in the most difficult places old lime deposits. Usually, to eliminate such residues, equipment must be unwound, soak parts in aggressive acid environments and to withstand them there and for two hours. But even after it is necessary to finish the surface with metal brushes or cleaners. If your gas boiler does not heat the water to the desired temperature, then the reason for the deposits of scale. The electromagnet makes all this work, not the surface of the surface, at the molecular level.

Installing the gas boiler allows you to forget about cold water in batteries and cranes. Double-circuit models are able to simultaneously work for heating and hot water supply (DHW) of the room. But what if the boiler does not heat the water? If you are faced with a similar problem, our recommendations will help find the cause and eliminate the problem with your own hands.

The principle of operation of the boiler

To figure out the cause of the breakdown, you need to understand how the boiler works. Double-circuit devices "Ariston", "Baksy" and other models have several blocks. In the gas site, ignition and burning occurs, the water assembly is responsible for the supply of water and pressure in the highway. The chimney block displays combustion products into the street.

As soon as you run the boiler, the pump is triggered, which pumps water into the system. A gas valve opens. The liquid circulates through the heat exchanger tubes, and the burner evenly warms its body. Sensors control the heating process. As soon as the temperature reaches the given, the gas supply is turned off, heating is stopped.

When the temperature begins to decline, the sensors will send a signal to the control module - the heating cycle will start again.

When you open the mixer, the flow sensor is activated. It gives a signal to switching the three-way valve for heating DHW. When the mixer closes, the valve switches to the heating system. Some models are equipped with a "Quick Start" mode. Then the valve periodically switches, heats the first, and the second heat exchanger.

Why the boiler warms badly, does not dial the temperature

No hot water? For what reasons the technique does not work? Sometimes it's in external factors. Consider more.

The device works, but does not heat or light warms

Airlock. Check if the air in the batteries did not accumulate. Using cranes, remove excess air. If you do not have an air vent on radiators, then you need to install it. By adjusting its crap, you can lower the accumulated air in the system.

Also inspect the valve for a blockage. Most often, he is clogged with skidding.

Vomor in radiators. After cooling, shut water from the pipes. If it is strongly contaminated, run across the batteries until it flows clean.

Invalid connection. If a hot stream does not go, make sure that the diameter of the pipes corresponds to the instructions declared. Hoses are connected correctly, lock valves are mounted.

Low pressure in the highway. It is not enough to open the valve and the ignition of the burner. Fresh water.

The accumulation of scale in the heat exchanger. It can be noted that the technique heats the fluid for a long time, the batteries are weakly sink. Clean the radiator tube from deposits. To do this, the node is better to remove, but it can be done not in all models. Therefore, remove the casing, turn off the device from gas and water. Connect the tube from the pump to the heat exchanger from the pump, drive the cleaning fluid on the system. Special funds can be chosen in the store. Then rinse the part with running water.

Adding reagents to the fluid of the coolant helps reduce the formation of salts on the details.

When buying it is important to pay attention to the brand and the model of the boiler. For example, manufacturers "", "", "", "", "" prohibit the use of the reagent. It is recommended to install cleaning filters or use distilled water.

Antifreeze can be applied to models, "", "", "," "," ". But for each manufacturer, a separate reagent is produced.

Voro filter. Another reason for poor battery warming. The mesh filter is clogged with small garbage, so it is periodically removed and cleaned under running water. With a strong lock or wear, it is better to replace the item.

Invalid adjustment. Check the set values \u200b\u200bon the panel. It may be selected too low temperatures, so the gas does not heat hot water.

Problems with the work of the circulation pump. Overheating, the pump is turned off when the hot water is turned on. Its power may not be enough to normal circulation. Adjust the settings.

Battery design does not suit your equipment. Each construction has its own permeability and heat transfer. Incorrect selection leads to a decrease in heating due to system patency.

Non-compliance with the liner of the highway. The problem is characteristic of systems with natural circulation, which is ensured by compliance with the installation standards. According to the documents, the bias of pipes for each trafficphone meter should be at least 10 mm. No slope - no heating. The coolant is stored, batteries remain cold.

Gas boiler does not turn on, does not give hot water on the DHW

The main cause of troubleshooting is salt deposits. The greater the layer of scale in the heat exchanger, the worse conductivity. Water heats up for a long time, a thin little warm stream flows at the exit. Also a piece of scale could get off and overlap the passage to the mixer. What to do in this situation, we described above.

Problems with flow sensor. The part works on the principle of the fan, which rotates due to the flow movement. The sensor may not work when clogged. To clean up without dismantling, open and close the crane, which is located near the circulation pump.

If the procedure did not help recover, you will have to remove the sensor, clean and install in place.

Three-way valve malfunction. If the valve jammed or he broke, it will not be possible to switch the water supply from the heating system to the DHW. The cause of the problem could serve the detail, gas hose or filter. Spend all the elements.

The reasons for troubleshooting a lot. Determine what problem arose in your loop will help us with the signs described. Pay attention to the equipment and compare with the specified problems. If it is not possible to solve the malfunction yourself, contact a specialist.