Beretta (gas boiler): instructions, reviews. Systems of heating of country and country houses. Boilers, gas speakers, water heaters - repair, service, operation. Installation and Installation Recommendations Beretta Ciao Maintenance Guide

Adjustments and maintenance of the Beretta Chao Boiler

Adjustment of the maximum and minimum power for the circuit of the DHW

- Fully open the crane of hot water.

- Set the Summer Switch.

- Install the temperature control in the DHW circuit to the maximum position.

- Turn the main switch to the "Included" position to include the electrical power supply of the Beretta Ciao 24 CSI boiler.

- Make sure the pressure displayed on the pressure gauge is stable; Or, take a milliammeter, connect it sequentially to the modulator and make sure that the modulator is groaning the maximum current current (120 mA for G20 and 165 MA gas for liquefied gas).

- Remove the protective cap with adjusting screws on the gas valve, gently approaching it with a screwdriver.

- Using a conventional SH10 wrench, rotate the maximum power adjustment nut to obtain the desired pressure value.

- Disconnect one terminal from the modulator.

- Wait until the pressure value displayed on the manometer does not stabilize at a minimum level.

- With a screwdriver or special key, rotate a red screw of the minimum power control so that the desired pressure value is displayed on the pressure gauge.

- Connect back to the terminal modulator.

- Close the crane of hot water.

- Gently and carefully put on the protective cap in place, on the adjusting screws.

Electronic regulation of the minimum and maximum power of the Beretta Chao boiler in heating mode

The electronic control function turns on and disconnected only with the jumper (JP1). On the control panel, green and red light indicators will flash alternately.

This feature can be included in one of the following ways:

- You can use meals on a fee when jumper JP1 is installed, and the operating mode switch is in the Winter position, regardless of whether any requests to work in another mode are available or not.

- By setting the JP1 jumper, while the switch mode switch must be in the "Winter" position, and there should be no current requests for heat production.

When this function is turned on, the burner ignition occurs, due to the fact that the demand for heat production for the heating system is simulated.

To perform the setup procedure, follow the instructions below:

- Disconnect the Beretta Ciao 24 CSI boiler.

- Remove the cladding to access the electronic board.

- Install the JP1 jumper, while the knobs located on the control panel will start performing the minimum control functions and the power maximum in heating mode.

- Make sure the switch mode switch is in the "Winter" position.

- Turn on the power supply of the unit. The electronic board is energized (230 volts).

- Rotate the temperature control knob in the heating circuit until the minimum gas pressure value for heating mode is reached.

- Install JP2 jumper.

- Rotate the temperature control handle in the DHW circuit until the maximum gas pressure value for heating mode is reached.

- Reconnect pressure compensation fitting with air intake chamber again.

Disconnect the pressure gauge and tighten the screw at the pressure measurement fittings.

To exit the setup mode without saving the specified values, do one of the following actions:

Set the operating mode switch to the position (OFF - off).

Disconnect the power supply.

Remove the jumper JP1 / JP2.

The setup mode is automatically completed, and at the same time the values \u200b\u200bof the minimum and maximum are not saved, after 15 minutes after its activation.

The setup mode is automatically completed in the case of a preliminary or final emergency stop. In this case, the specified parameters will also not be saved.

To configure only the maximum power in heating mode, you can remove the jumper JP2 (in order to save maximum), after which it is possible to exit the setup mode, without saving a minimum, to install the operating mode switch to the position (OFF - off) or turn off the boiler power Beretta Ciao 24. After each change in the adjustment of the gas valve, install the seal on it.

At the end of the adjustments:

- Return the temperature mounted on the temperature temperature thermostat to the desired value.

- Translate the water temperature controller in the heating system to the desired value.

- Close the panel with control and control devices.

- Replace facing.

Maintenance Boiler Beretta Ciao 24 CSI

To boileta Beretta Chao worked securely and efficiently, it should be systematically subject to maintenance at certain time intervals.

The frequency of maintenance depends on the specific conditions of installation and operation, but in any case it is recommended that a qualified service specialist can carry out maintenance at least once a year.

In the case of repair or maintenance of structures located near the chimney and / or devices for removing flue gases and their components, turn off the device, and at the end of the work, a qualified specialist should check the operation of the boiler.

Before you perform any cleaning or maintenance operation, set the operating mode switch to the OFF / RESET position and disconnect the common switch and overcap the gas supply pipe with a crane installed in front of the device.

With the scheduled maintenance of the Beretta Ciao 24 CSI boiler, the following operations are performed:

Removal of oxides from the burner;

Removal of scale inside the heat exchanger (as needed);

Check and overall cleaning of smokers and air ducts;

Checking the appearance of the unit;

Diagnostics of ignition, shutdown and boiler operations Beretta Ciao 24 CSI, both in DHW mode and in heating mode;

Control of the tightness of the connecting adapters and pipelines of the compound of gas and water;

Checking gas flow rate at maximum and minimum power;

Control of the position of the electrode of the ignition-detection of the flame;

Diagnostics of the operation of the security device in the disappearance of the gas;

Checking the combustion parameters

To perform combustion product analysis, follow the following sequence of actions:

- Open the crane of hot water to the maximum.

- Set the operating mode switch Mode "Summer".

- Set the temperature controller in the DHW circuit to the maximum value.

- Evalid the screw on the lid, which closes the fitting, serving to select the combustion products for analysis and set the gas analyzer probe.

- Turn on the electric power supply of the boiler.

The boiler will work at maximum power, which will allow the analysis of combustion products. After completion of the measurements, close the crane of hot water, remove the gas analyzer probe and close the fitting that serves for the selection of combustion products for analysis, carefully twisting the screw, which before that was removed.

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

_______________________________________________________________________________

__________________________________________________________________________

Operation and repair of boilers

Proterm Panther

Italian boilers for gas heating under the brand of Beretta rightfully deserved popularity among consumers. We will look at what the secret here, in the way, we present the instructions on the gas boiler of Beretta, as well as indicate possible malfunctions of this technique.

Like each brand, the brand described is highlighted by characteristic advantages. Here are the main one:

  • acceptable price, not so big as other famous brands;
  • the Italian company "Riello", as a manufacturer of this equipment, multistage controls the full cycle of manufacturing equipment.

Products are divided into several varieties of the model range. As always, this is a complete variety to meet all customer needs. There are outdoor, wall models with one and two contours. Here is the main division of models.

  1. City - "Beretta City", the most "running" equipment with a capacity of 24 kW. Best features.
  2. EXCLUSIVE - Here in the design of boilers, the maximum convenience of management and comfort, obtained as a result of the equipment, are combined. For example, in addition to the "Winter", "Summer" modes, there are still modes "Winter Comfort" and "Summer Comfort".
  3. Ciao is a low-power boiler with a convenient control unit.
  4. Boiler - equipment with built-in boiler.

Let's now try to figure out what the technical characteristics of this equipment, because of which it is so popular. To do this, consider two specific models.

Beretta Ciao 24 CAI

This unit is designed for mounting on the wall, it has two contours for warming up - the contours of heating and hot water supply, with the open-type burning chamber. What are the main advantages of this equipment? We specify the following list.

  1. There is a display display.
  2. Power can be adjusted smoothly.
  3. Automatic adjustment of the temperature regime of the coolant.
  4. The circulation pump has three speeds and protected from failures.
  5. Ability to reconfigure equipment for liquefied gas.
  6. The wall thickness of the heat exchanger is increased on the last models.
  7. Installation is the control of the flame of the ionization type.
  8. Water pressure controls the hydraulic press service.
  9. There is also control of smoke removal.

In order to understand how this unit works, we give a brief instruction on this two-konturic gas berette wallpaper.

  1. Work modes are displayed by special icons on the indicator panel of the unit.
  2. To activate the equipment, you must turn on the power supply, open the gas crane, adjust the room temperature controller and set the "winter" or "summer" mode.
  3. Disconnection is made by a special button "Shutdown".

In the original, instruction on the wall-mounted gas boiler Beretta has electrical, hydraulic schemes, possible problems and description of the installation rules with drawings. After eliminating minor problems, the boiler starts the reboot button.

The described apparatus has some relative disadvantages. We list them below:

  • since the combustion chamber is open, it is necessary to have an equipped chimney in the room;
  • possible clogging of sensors.

With this model we figured out, and now we will study another model.

Wall Beretta City 24 CSI

This equipment also provides for mounting on the wall. There are also two contours here, but the chamber for burning is closed, respectively, the decomposition of smoke is forced. The capacity is 24 kW, and the area of \u200b\u200bheated premises can reach 240 m2. The main best quality equipment is listed below.

  • copper primary heat exchanger;
  • protection against freezing and overheating;
  • automatic diagnostics of equipment errors;
  • the heating temperature of the coolant is automatically adjustable;
  • power is adjustable smoothly;
  • protection against frozen and block pump.

As we see, this model has a function similar to that of the previous model. Now we will briefly give the instruction manual for the described gas pot of Beretta.

  1. The indicator panel also uses icons, conventional images are decrypted in a technical passport.
  2. It is possible to connect the remote control.
  3. Mounting rules are painted in detail on the pages of the technical passport.
  4. The passport shows the connection scheme to the horizontal coaxial chimney, which must be purchased separately.
  5. To start the equipment, you must fill the system with water, turn on the power, open the gas crane, set the regulator to room temperature. Include "Winter" or "Summer" mode.
  6. Turning off the equipment is carried out with the shutdown button.

Error codes are also specified. That is, this is encrypted faults that can show a two-round gas pot of Beretta on the indicator panel. However, we will talk about them now more.

Comparison and troubleshooting



To summarize a certain result, we made a consolidated table on the two models described. The result is: the boilers are approximately similar, both are very attractive for the consumer. Here is this table:

The table below includes information about consumers faults of a gas boilet gas boiler.
We write down that you can try to do with some kind of problems with your own hands.

  1. Among the faults of the Beretta gas boiler, there may be a breakdown, in which the unit does not turn on. Most likely, the reason is either in the absence of water, or in the absence of power supply. The worst alignment is a system board breakdown. Only the service service will help here.
  2. It is possible to block due to excessive chimney pressure, but this may occur due to strong street wind.
  3. Sensor malfunctions The automation must determine the itself.
  4. Equipment may also not be included due to condensate in chimney, the latter must be checked among other things if the unit does not turn on.
  5. There are cases of refusal of equipment because of the Inea at the exit of the chimney. The sensor is triggered, as a result, the instrument does not work.

Here are the main problems with which you can encounter during the operation of the described boiler equipment.

Beretta heating boilers are comfort and room heating at the same time. With the help of heating equipment of Beretta, the required temperature regime will be maintained in the building and to heat the liquid for the needs of the consumer. The characteristics of Bosch heating equipment are described.

Boiler aggregates can function both on firewood and gas. Today, the heating systems market presents a large range of devices that differ from among themselves the power indicators, functionality and price. Relying on your desires and thickness of the wallet, you can choose a suitable heating device for your home.

The main advantages of Beretta gas devices:

  • No need to accumulate energy material;
  • Comfortable overall dimensions;
  • The ability to heal water;
  • Automatic temperature control system indoor;
  • Availability, reliability, quality.

Beretta gas type boilers are used both with natural and forced circulating heat carrier swung in the heating system. They have burners made of "stainless steel" with a reduced noise threshold.

Adjusting the level of the working fire of the device can be carried out both piezoelectric and electrical element.

Equipment made by Beretta can work from the network, and may not even need electricity, which is a considerable plus for Russia:

  • Efficiency;
  • The ability to install in houses without electricity.

Beretta's equipment has a high efficiency of CPD 97% and meets European quality standards.

Types of gas boilers heating beretta

Today, the Russian market provides the following types of gas type boilers:

  • Wall boilers - this equipment has a small weight and dimensions, is perfect for the heating of private houses;
  • Floor boilers, the most popular model is Beretta Novella Avtonom 64, which has the status of the most effective in the autonomous heating of the room;
  • Single-mounted equipment intended for the heating of the room and having a function of connecting a boiler for water heating;

Instruments with 2 contours capable of performing two functions at the same time:

  • warm the liquid for household needs;
  • maintain a comfortable temperature in the building;

Models of boiler equipment belonging to the boilers of gas type of Beretta wall mount, with two heating circuits are considered the most popular on the territory of Russia.

The following models of Beretta gas boilers are in demand:

  • beretta Ciao 24 CSI gas boiler - the boiler is equipped with a closed combustion chamber, designed to heat the room in 240 sq.m. Variation of the Beretta City 24 CSI model;
  • gas boilet Beretta Novella auton is a solid fuel boiler made of cast iron. It is intended for the heating of the room without connecting to the electrical network.

Operating Instructions for the Gas Boiler Beretta

Gas heating equipment of Beretta meets all international quality standards. Gas boilers have not only a high level of wear resistance, but also boast ease of use.

For example, in order to adjust the gas boiler, it will be necessary to smoothly and evenly adjust the power of the device. Determine with the desired flame rate on the burner, as well as check the gas supply.

It should be verified that the gas pressure corresponds to the norm.

Faults of the Beretta Gas Boiler

Nothing absolutely, therefore any device can get out, even the gas boiler of Beretta. The most common breakdown during the operation of the heating device is considered to be the failure of a gas burner or a decrease in the gas pressure level.

Have you long come across the problems of central heating or hot water supply? These questions can be solved by installing a gas boiler.

Problems with central heating

The solution can be a single-mounted or double-circuit boiler. The first variety is able to provide the process of heating. With the help of a double-circuit device, it is possible not only to heating the premises, but also heating the heat carrier to solve household problems. If you decide to purchase a two-round gas boiler "Beretta", then it is worth remembering that its installation will be quite troublesome and time consuming.

Gas boiler installation rules

Many people like the products of the brand "Beretta". The gas boiler of this manufacturer can be purchased at an affordable cost. Before you proceed to install the device in a private house, you will need to prepare some documentation, as well as implement certain actions. Thus, it will take a contract for the supply of gas for the developer, the installation project. Specifications must be agreed with the Gas Service representative.

Project documentation is most often developed by specialists of institutions that work on the relevant license. Gas equipment should be established by professionals from assembly organizations.

According to users, the engineer of the district organization should visit the object in order to check whether the gas is supposed to be supplied to the kitchen and in the fiber, whether the requirements are met. It is often quite possible. Recently, consumers choose the goods of the brand "Beretta", the gas boiler is also no exception.

After a specialist is convinced that all the rules are observed, he will give an opinion, on its basis it will be possible to open a valve that leads to equipment. The heating system should be crimped to p \u003d 1.8 atm.

It is important to drain the heating system. Experienced users emphasize that the compounds must be tested for tightness, it is necessary to establish a voltage stabilizer for equipment and a source that will be able to remember that antifreeze cannot be added to the heating coolant in any way.

Reviews on the rules of the boiler room

When wall-mounted gas boilers "Beretta" are purchased, they must be installed in the premises to which certain requirements are presented. When in a private single-headed house, a boiler room or fuel can be placed on any floor, including on the base, on the roof, in the attic or in the basement. The restriction applies only to residential premises, as well as on the bathroom and the bathroom, where the cauldron is prohibited. Consumers emphasize that it is important to determine the volume of the boiler room, taking into account the thermal power of the equipment, the capacity of water heaters, as well as flow treads.

For reference

If you decide to install a gas boiler "Beretta", then consider that when it is mounted it is important to take into account some factors. So, if the device has a closed combustion chamber, then the volume of the boiler room is not normalized. It does not necessarily have the window. For removal and supply of oxygen, it is important to ensure air flow in the required volume.

Thus, if you installed the boiler, the power of which is 23.3 kilowatta, then the gas will be burned in the volume of 2.5 cubic meters per hour. In order to ensure complete combustion of this volume, you need 30 cubic meters of air per hour. If you do not guarantee sufficient air intake, the gas will not be burned completely, as a result, the harmful substance will be concentrated, its inhalation can negatively affect human health. If inhaling for just 15 minutes, then death may come. Oxygen should penetrate not only outside, but also from other rooms at home. This can be ensured by the presence of a gap, which will be located between the door and the surface of the floor. It is also recommended to install the grille at the bottom of the door.

The gas boiler "Beretta" must be installed on the floor with a retreat of ten centimeters from the wall, which should be made from non-combustible material. If there are no such surfaces, then you can set a special protection that will be made of refractory material.

Installation Instructions

If the listed requirements are not met, the gas service will not allow connecting the boiler to the central highway. However, the need to comply with these requirements is dictated by no bureaucracy, but experience, as well as fire safety. Restrictions concern not only equipment and installation works, but also the premises where the boiler is supposed to install.

It is necessary to remember that the boiler room area should be 4 meters square or more, and the ceilings are not lower than 2.5 meters. When installing the door, it should be borne in mind that its width should be 80 cm or more. If you decide to prefer the manufacturer of Beretta, the gas boiler of this company will meet all safety requirements, but it is important to comply with the established rules. They suggest the need to illuminate the equipment in a natural way through the window opening. On 10 square meters of one room should have 0.3 meters square window opening. It is very important to organize intensive ventilation, because the combustion of gas is ensured on the principle of fresh air inflow. To ensure an external air intake, it is necessary to ensure the presence of an opening of 8 centimeters of square to 1 kilowatt of the power of the device.

Additional instructions

Gas boiler "Beretta", the reviews about which only positive should be connected to the pipes of the gas pipeline that are made exclusively from the metal. The use of flexible sleeves is permissible only to connect individual consumers. Chimney must have a cross section that corresponds to the parameters of the power of the unit. If it is equal to 30 kilowatts, the chimney diameter should be 130 millimeters. With increasing power up to 40 kilowatt, the diameter increases to 170 millimeters. It is impossible to allow the cross-sectional area to be less than the opening area for connecting this element.

If you decide to choose a gas boiler "Beretta", the installation instructions for which is presented in the article, it is important to remember that the upper end of the chimney should be displayed above the skate by 0.5 meters. This value is minimal.

What else should pay attention

Be sure to ensure the presence of a gas analyzer to be located in the boiler room. With this instrument, you can warn gas leakage. The device must be equipped with an electric valve. The latter is designed if necessary, overlapping the gas supply.

Manufacturer "Beretta", the gas boiler you can purchase in specialized points of sale, indicates the possibility of the location of the equipment in the basement room exclusively for the same house. As for multi-storey buildings, the installation of the device in the basement is prohibited.